Important Information; Known Issues; Hsg80 Transparent Mode Not Supported With Ibm Aix - HP StorageWorks 2/140 - Director Switch Release Note

Fw 04.01.02 and sw 06.03.01 director release notes
Hide thumbs Also See for StorageWorks 2/140 - Director Switch:
Table of Contents

Advertisement

Important Information

This section describes important information related to the Director 2/64 and
Director 2/140.
HAFM Upgrade Required for Firmware Version 04.01.02 Build 04
If you are using the HAFM server to manage the Director 2/140, Director 2/64,
Edge Switch 2/32, Edge Switch 2/24, and/or Edge Switch 2/16, and they are
running firmware version 04.01.02 build 4, you need to upgrade HAFM to version
06.03.01 build 5 (minimum). For more information on upgrading software
versions, refer to the HP StorageWorks HA-Fabric Manager User Guide. The features
of this software version are detailed in the accompanying manuals.
Zoning is Disabled by Default
The default zone on the Director 2/64 and the Director 2/140 is disabled by
default. Zoning must be configured in order for any devices connected to the
director to communicate.

Known Issues

This section describes the known issues related to the Director 2/64 and
Director 2/140.

HSG80 Transparent Mode Not Supported with IBM AIX

Use of an HSG80 with IBM AIX is restricted to operating the HSG80 in Multibus
mode with the Director 2/64 and Director 2/140. Transparent mode is not
supported at this time.
Workaround
None.
Director Release Notes