Isolating Faults - HP A5272A - SureStore E Disk System SC10 Storage Enclosure Service Manual

Hp surestore e disk system sc10 user and service guide
Hide thumbs Also See for A5272A - SureStore E Disk System SC10 Storage Enclosure:
Table of Contents

Advertisement

Isolating Faults

Problem
HW Event
Description
Category
Installed
none
product does
not power on
System fault
none
LED is on
Critical
Audio alarm
none
when BCC
installed
BCC Fault
Critical
LED is on
Fan LED is
Critical
amber
LED
STM
State
Status
Probable Cause/Solution
System
none
– Neither power cord is plugged in.
power LED
– The power switch is not pressed.
off
– AC breaker is tripped.
– AC power source has failed.
– The PDU/PDRU is defective.
– Power switch is defective.
– A faulty component is causing power
Power
Power
– The power supply is not plugged in.
supply
supply Not
– The PDU/PDRU or primary power source
LED off
Available
Part fault
Critical
A component has failed. See problem
LED on
descriptions below.
BCC Fault
Disk Not
BCC DIP switch settings do not match peer
flashing
Available
BCC switch settings. Reset switches.
BCC Fault
Critical
BCC hardware is faulty. Replace the BCC.
on
Amber
Critical
Fan has slowed or stopped. Replace the
fan.
supplies to turn off. Remove all
components and reinsert one at a time
until the faulty component is isolated.
has failed.
99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk system sc10

Table of Contents