Event code
Description
0x805
Single Bit Error.
0x820
Soft Media Error. The SP successfully
cleared a media defect.
0x840
Disk Sector Invalidated. The LUN that
owns this disk encountered a condition
which required the firmware to
invalidate a sector on the unit. The
firmware did this to ensure that
incorrect data is not returned to the
host in the future.
ÃÃ
Event code
Description
0x901
Hard SCSI error. An abnormal SCSI bus or disk drive event was detected and
could not be cleared through retry operations.
0x903
Fan Removed. A fan pack has been shut down or removed from the disk array.
0x904
VSC Removed. A VSC (power supply) has been shut down or removed from the
disk array.
0x905
Chassis Overtemperature. A chassis overtemperature condition has been
detected. The controller attempts corrective action.
0x906
Unit Shutdown. The Unit of which this drive is a member has been shutdown and
can no longer be accessed by the host.
0x907
Controller Firmware (SP microcode) Panic. A fatal firmware error has occurred;
as a result, the program running in the SP has reset SP. The SP was restarted
and continued normally.
8-36
Recommended threshold
The SP's tolerance level for single bit
errors in the read cache has been
exceeded.
Notify the user after three
errors/month/FRU.