Event code
Description
0x622
Background Verify Complete. Disk array has completed background checkpoint
verification of the accuracy and completeness of the parity check data in a
RAID-5, RAID-3, RAID-1, or RAID-1/0 LUN.
0x623
Fan Pack Disable/Door Open. Fans disabled because the fan pack door was
opened. The disk array shuts down if the fans are not operational within two
minutes.
0x624
Fan Pack Enable/Door Close. Fans were enabled after the fan pack door was
closed.
0x630
Fan Installed. Disk array has detected that a fan has been installed or replaced.
0x631
VSC Installed. Disk array has detected that a VSC has been installed or
replaced.
0x632
AC Box Installed. An AC Box has been installed.
0x633
Fan Speed Increased. Disk array has detected an increase in a fan's speed,
perhaps because temperature rose or another fan failed.
0x634
Fan Speed Decreased. The fan speed has returned to normal.
0x635
Inconsistent Check Information. The SP has detected an inconsistency in the
sector based check codes.
0x637
BBU Recharging. The Battery Backup Unit in this disk array is recharging.
0x638
BBU Enabled. The Battery Backup Unit in this array has been enabled for use.
0x639
System Cache Enabled. Storage system cache has become ready.
0x641
Rebuild Aborted. A background rebuild operation has aborted prior to
completing the entire disk.
0x643
SP Initializing. Peer (second) SP was detected in the chassis.
0x644
Peer SP Inserted. This SP has been informed by its peer SP that the peer has
completed its power up initialization sequence.
0x645
CRU Bound. Extended status is unit number. This message is logged once for
each CRU in a LUN at the completion of a Bind operation.
0x646
CRU Unbound. Extended status is unit number. This message is logged once for
each CRU in a LUN at the completion of an Unbind.
0x647
Fuse Bad. Extended status is fuse number. This message is logged once at the
completion of each powerup for any bad fuse detected by the SP.
8-32