Table B.1 Setting Terminal: Cn2 - Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive Product/Maintenance Manual

Manual/user guide
Table of Contents

Advertisement

B.1
Setting Terminals (MP model only)
Setting item
Pins
9 - 10
7 - 8
SCSI ID
(Open) Open
(Open) Open
(Open) Open
(Open) Open
(Open) Short
(Open) Short
(Open) Short
(Open) Short
Short
Short
Short
Short
Short
Short
Short
Short
Write protect
Open
Short
Setting item
11 - 12
Motor start mode
Open
Short
Force Narrow
Force Single Ended
Terminating power
supply
* Setting at factory shipment
Note:
See the description of Section 5.3 for details of the setting requirements and notes.
B - 2
Table B.1
Setting terminal: CN2
5 - 6
3 - 4
1 - 2
Open
Open
SCSI ID #0
Open
Short
SCSI ID #1
Short
Open
SCSI ID #2
Short
Short
SCSI ID #3
Open
Open
SCSI ID #4
Open
Short
SCSI ID #5
Short
Open
SCSI ID #6
Short
Short
SCSI ID #7
Open
Open
Open
SCSI ID #8
Open
Open
Short
SCSI ID #9
Open
Short
Open
SCSI ID #10 (16-bit SCSI only)
Open
Short
Short
SCSI ID #11 (16-bit SCSI only)
Short
Open
Open
SCSI ID #12 (16-bit SCSI only)
Short
Open
Short
SCSI ID #13 (16-bit SCSI only)
Short
Short
Open
SCSI ID #14 (16-bit SCSI only)
Short
Short
Short
SCSI ID #15 (16-bit SCSI only) (*)
Write operation is enabled. (*)
Write operation is disabled.
Pins
13 - 14
15 - 16
23 - 24
Open
Short
Open
Short
Open
Short
C141-E128-01EN
Setting contents
(Common to 8-bit and 16-bit SCSI)
(Common to 8-bit and 16-bit SCSI)
(Common to 8-bit and 16-bit SCSI)
(Common to 8-bit and 16-bit SCSI)
(Common to 8-bit and 16-bit SCSI)
(Common to 8-bit and 16-bit SCSI)
(Common to 8-bit and 16-bit SCSI)
(Common to 8-bit and 16-bit SCSI)
(16-bit SCSI only)
(16-bit SCSI only)
Setting contents
Started by the START/STOP command
Started by turning the power supply on (*)
Width of 16 bit bus (*)
Width of 8 bit bus
Follows DIFFSNS signal level on SCSI bus (*)
Single-Ended mode
Does not supply terminating resistor power to SCSI
BUS
Supply terminating resistor power to SCSI BUS (*)

Advertisement

Table of Contents
loading