Chapter 7 Error Analysis; Error Analysis Information Collection; Sense Data; Sense Key, Sense Code, And Subsense Code - Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive Product/Maintenance Manual

Manual/user guide
Table of Contents

Advertisement

CHAPTER 7
This chapter explains in detail how sense data collected from a disk drive is used for troubleshooting.
Sense data reflects an error in the disk drive, and helps with troubleshooting.
A sense key, sense code, and subsense code, taken from various sense data are repeated. Also in this
chapter, troubleshooting is performed using these three codes. Unless otherwise specified, "sense data"
means the above three codes. When sense data is represented as (x-xx-xx), the leftmost x is a sense key,
the middle xx is a sense code, and the rightmost x is a subsense code.
7.1

Error Analysis Information Collection

7.1.1

Sense data

When IDD posts a CHECK CONDITION status or detects a fatal error in the SCSI bus, the
current command or queued command is cleared. In such a case, the IDD generates sense data
about the command-issuing INIT. The INIT can read the sense data by issuing a REQUEST
SENSE command.
Even if a transfer byte length that is shorter than the sense data length of the tested device is
specified, the command terminates normally. In this case, however, the INIT receives part of the
sense data, but the remaining part of the sense data is lost.
For details of the REQUEST SENSE command, refer to the SCSI Logical Interface Specifications.
7.1.2

Sense key, sense code, and subsense code

If an error is detected in a disk drive, the error status is indicated in the sense data collected from
the disk drive. Figure 7.1 shows the positions of a sense key, sense code, and subsense code.
ERROR ANALYSIS
7.1
Error Analysis Information Collection
7.2

Sense Data Analysis