Configure "Door Forced Open" Alarm Feature:
When enabled, doors that are forced open will trigger an alarm. The alarm will activate
the relays you specify. The relays can remain active until the relay time expires or until
the alarm condition clears.
Press
1
Enter Alarm Option (0-2). Then (#)
2
Option 0=Disabled
Option 1= Enabled Relays will activate until relay time expires
(See Set Relay Activation Time on page 23 (Step 3) for more information)
Option 2=Enabled Relays will activate until the alarm condition clears
Activate (1) or Deactivate (0) Relays (0000-1111). Then (#)
3
Example:
When a "Door Held Open" alarm condition occurs, relay "4" will activate until the relay
condition expires. If the alarm relay controls a siren, the siren will sound until the relay
time expires.
Setting "Strikes and Out" (Number of Entry Code Attempts before Disabling Unit):
The "Strikes and Out" feature prohibits unauthorized persons from guessing an entry
code or the unit password and entering programming mode. Anyone entering an entry
code or password will have a set number of times to correctly enter their code. Each
time the code is entered incorrectly, it is a "strike". After "x" number of "strikes", the
system will disallow code entry at the unit for 3 minutes.
Press
1
Enter Maximum Number of Strikes and Outs Allowed (0-5). Then (#)
2
0=Disabled
Configure "Strikes and Out" Alarm Feature:
When enabled, an alarm will trigger if someone enters an erroneous entry code or the
unit password on the unit keypad more than the maximum number allowed (see above).
The alarm will activate the relays you specify. The relays can remain active until the relay
time expires or until the alarm condition clears.
Press
1
Enter Alarm Option (0-2). Then (#)
2
Option 0=Disabled
Option 1= Enabled Relays will activate until relay time expires
(See Set Relay Activation Time on page 23 (Step 3) for more information)
Option 2=Enabled Relays will activate until the alarm condition clears
Activate (1) or Deactivate (0) Relays (0000-1111). Then (#)
3
Example:
When a "Strikes and Out" alarm condition occurs, relay "4" will activate until the relay
time expires.
Factory Setting: Disabled
Then
(1st digit=Relay 4, 2nd digit=Relay 3, etc.)
1
2
Then
Then
(1st digit=Relay 4, 2nd digit=Relay 3, etc.)
1
2
Page 55
103
Relay 4
Relay 3 Relay 2 Relay 1
Activate
Deact Deact Deact
Factory Setting: 3 Times
104
Factory Setting: Disabled
Relay 4
Relay 3 Relay 2 Relay 1
Activate
Deact Deact Deact
3
17
3