Quick Reference Guide; All - Chamberlain Elite EL2000 Programming Manual

El25-keypad programming manual
Hide thumbs Also See for Elite EL2000:
Table of Contents

Advertisement

Quick Reference
Guide for Keypad Programming the Units
Programming
Page
Number
15
Entering Programming Mode
***
0
15
Exiting Programming Mode
1
56
Change or Verify the Unit's Password
2
20
Set Unit ID Number and No. in Chain
3
52
Set the Clock
4
52
Enable/Disable Daylight Savings Time
5
61
Set Visitor Talk Time
6
29
Set Directory Code Length
7
35
Set Entry Code Length
9
59
Enable/Disable Call Waiting
10
31
Enable/Disable Do Not Disturb Schedule
11
51
Enable/Disable Unlock Time Zone
12
53
Enable/Disable Anti-Passback
13
53
Set Anti-Passback Time
14
Set Maximum Number of Rings
Allowed Before Aborting Attempt
15
Set Standard Single Ring or Double
Ring Response
16
58
Number of Rings Before Unit Answers
17
55
Set "Strikes" and "Out"
18
59
Set Call Volume
Set Voice Response Volume
Set Beep Response Volume
19
59
Set Microphone Volume
20
58
Enable/Disable the Telco Mode
21
67
Enable/Disable Direct Commands
22
60
Enable/Disable Voice Mail
23
60
Enable/Disable Access Granted Beeps
24
70
Enable/Disable Real-Time Monitoring
25
61
Return to Menu Programming
26
61
Enable/Disable All Door Access Granted
Optional Steps Indicated in BOLD type, all other steps are Required
Important: The Pound Key (#) must be used as Data Field Separator and to Save Data at the end of the
sequence. Time must be entered using a 24-hour format (8AM=0800, 3PM=1500 etc.). If you make an
error during an entry, press the asterisk key (*) to begin again.
Description of Task
Page 4
Factory
Programming
Setting
Procedure
*** (6 Digit Password)
0 #
000000
1 # (1 to change; 2 to verify) #
(six-digit coded) #
Unit ID 1,
2 # (unit ID number, 1-7) #
Chain No. 1
(Number of Units in Chain, 1-7) #
3 # yymmdd # (day of the week)
# hhmm #
Enabled
4 # (0=disable; 1=enable) #
60 Seconds
5 # (15-250 seconds) #
3 Digits
6 # (1-4 ) #
4 Digits
7 # (3-9) #
Enabled
9 # (0=disable; 1=enable) #
Disabled
10 # (directory code) #
(0=disable; 1=enable) #
Enabled
11 # (0=disable; 1=enable) #
Disabled
12 # Enable/Disable True Anti-
Passback (0=disable; 1=enable) #
Enable/Disable Timed Anti-
Passback (0=disable; 1=enable) #
3 Minutes
13 # (1-60 minutes) #
5 Rings
14 # (1-9) #
1=Double Ring
15 # (0-1; 0=one long ring,
1=double ring) #
5 Rings
16 # (0-15) # Each unit in chain
must have same setting
3 Errors
17 # (max errors, 0-5) #
5, 2, 2
18 # (0=mute; 1-10, 1 is low and
10 is high) # (0=mute; 1=low;
2=medium; 3=high) # (0-3) #
5
19 # (0=mute, 1-10, 1 is low and
10 is high) #
Enabled
20 # (0=disable; 1=enable) #
Enabled
21 # (0=disable, 1=enable) #
Disabled
22 # (0=disable, 1=enable) #
Enabled
23 # (0=disable, 1=enable) #
Disabled
24 # (0=disable, 1=enable) #
25 #
Disabled
26 # (0=disable, 1=enable) #

Hide quick links: