Controls and Connections
1 INIT button
The INIT button allows resetting the RCM-810 to factory settings. Press the button for at least 3 seconds
using e.g. a small screwdriver. Table 4.1 lists the factory settings of the RCM-810 module.
CAUTION:
All RCM-810 parameters configured via IRIS-Net are discarded when pressing the INIT
button.
Amplifier & Channel Labels
Control Ports and Job Numbers
2 CAN ADDRESS Selector Switch
The two address selector switches are for setting the network address of the RCM-810. CAN networks
support addresses in the range of 01 to 250 (FA hex). Addressing has to be carried out in the hexadecimal
number system. The LOW selector switch sets the lower digit, while HIGH sets the higher digit.
CAUTION:
Each address may exist only once in a system. Otherwise, network conflicts may arise.
HIGH
Address 0 (00 hex, delivery status) disables remote communication between the RCM-810 and the bus. The module does not
appear in the system, even though it is physically connected to the CAN-bus.
16
Owner's Manual
Illustration 4.1: Controls and Connections of the RCM-810
Parameter
CAN-Bus data rate
Power-On-Delay
Supervision
VLD
Table 4.1: Factory Settings of RCM-810
LOW
Address
0
0
Stand-alone
0
1...F
1...15
1
0...F
16...31
2
0...F
32...47
3
0...F
48...63
4
0...F
64...79
5
0...F
80...95
6
0...F
96...111
7
0...F
112...127
Table 4.2: CAN addresses
Value
10 kbit/s
0 ms
RCM-810 Module, RCM-810 Input, RCM-810 Output
not configured
not configured
deactivated
HIGH
LOW
8
0...F
9
0...F
A
0...F
B
0...F
C
0...F
D
0...F
E
0...F
F
0...A
F
B...F
Address
128...143
144...159
160...175
176...191
192...207
208...223
224...239
240...250
reserved