4. Use a clean area of the cleaning pad to wipe the thermal grease from the
5. Use the thermal-grease syringe to place nine uniformly spaced dots of 0.02 mL
6. Continue with step 11 on page 41.

Installing a USB Flash key

Use these instructions to install a USB Flash key in the blade server.
The following illustration shows the installation of the USB Flash key.
To install a USB module, complete the following steps:
microprocessor; then, dispose of the cleaning pad after all of the thermal grease
is removed.
0.02 mL of thermal
Microprocessor
each on the top of the microprocessor.
Note: 0.01mL is one tick mark on the syringe. If the grease is properly applied,
approximately half (0.22 mL) of the grease will remain in the syringe.
1. Before you begin, read "Safety" on page v and "Installation guidelines" on
page 21.
2. Read the documentation that comes with the DIMMs.
3. If the blade server is installed in a BladeCenter unit, remove it (see
"Removing the blade server from the BladeCenter unit" on page 23 for
instructions).
grease
Chapter 3. Installing options
43