Table 2. POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the part listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
00180600
PCI device built-in self test failure, PCI
bridge error.
00180700
PCI device not responding.
00180xxx
The PCI adapter has requested resources
that are not available.
00181000
General PCI error.
36
IBM IntelliStation Z Pro Type 9228: Installation Guide
Action
1. Run the Configuration/Setup Utility program.
2. Reseat each adapter.
Note: If an error LED is lit on an adapter, reseat
that adapter first. If no LEDs are lit, reseat each
adapter one at a time, restarting the computer
each time to isolate the failing adapter.
3. Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a. Failing adapter
b. (Trained service technician only) System board
1. Run the Configuration/Setup Utility program, select
Devices and I/O Ports, and make sure that the
device is enabled.
2. Reseat each adapter.
Note: If an error LED is lit on an adapter, reseat
that adapter first; if no LEDs are lit, reseat each
adapter one at a time, restarting the computer
each time, to isolate the failing adapter.
3. Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a. Failing adapter
b. (Trained service technician only) System board
1. Reorder the adapters in the PCI slots.
2. Verify that the boot device is positioned early in the
scan order so that it is executed by POST.
3. Verify that all adapters are set correctly in the
Configuration/Setup Utility program, changing
memory settings if necessary.
4. Remove an adapter to make more memory
available to the adapters.
5. Disable the adapter BIOS on the adapter (see
documentation provided with the adapter).
6. (Trained service technician only) Replace the
system board.
1. Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a. The adapter
b. (Trained service technician only) System board