Complete Cabling For An Eva6400 2C6D To 0C6D Expansion - HP 6400/8400 Reference Manual

Enterprise virtual array expansion rack
Hide thumbs Also See for 6400/8400:
Table of Contents

Advertisement

3.
Unplug DP2-A on controller A from P1 (I/O-A) on disk enclosure 4 (S-4) and:
a.
Connect DP2-A on controller A to P1 (I/O-A) on disk enclosure 10 (S-10).
b.
Connect P1 (I/O-A) on disk enclosure 4 (S-4) to P2 on disk enclosure 12 (S-12).
c.
Repeat
Step
2.
4.
Unplug DP1-B on controller B from P1 (I/O-B) on disk enclosure 1 (S-1) and:
a.
Connect DP1-B on controller B to P1 (I/O-B) on disk enclosure 7 (S-7).
b.
Connect P1 (I/O-B) on disk enclosure 1 (S-1) to P2 (I/O-B) on disk enclosure 9 (S-9).
c.
Repeat
Step
2.
5.
Unplug DP2-B on controller B from P1 (I/O-B) on disk enclosure 4 (S-4) and:
a.
Connect DP2-B on controller B to P1 (I/O-B) on disk enclosure 10 (S-10).
b.
Connect P1 (I/O-B) on disk enclosure 4 (S-4) to P2 (I/O-B) on disk enclosure 12 (S-12).
c.
Repeat
Step
2.
Figure 23
shows the completed cabling for an EVA6400 2C6D to 0C6D expansion.
Figure 23 Complete cabling for an EVA6400 2C6D to 0C6D expansion
.
HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide