24-inch wide laundry center washer-electric dryer

Advertisement

III. MAKE
FOUR-WIRE
ELECTRICAL
CONNECTION
TO RECEPTACLE
Use a 4-wire power supply cord:
Fire Hazard
Use a new UL approved 30 ampere
power supply cord.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or center
wire) to center terminal (silver).
Ground wire (green or bare wire)
must be connected to green ground
connector.
Connect remaining 2 supply wires
to remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to follow these instructions
can result in death, fire, or electrical
shock.
Local codes may permit the use of
a U.L.-listed, 120/240wolt
minimum,
30-ampere, dryer power supply cord
kit (pigtail). Power s_,Jpptycord should
be type SF:{Dor SRr)T and be at least
four feet long. The wires that connect
to the laundry center must end with
ring terminals or spade terminals with
upturned ends.
For mobile homes or other four-wire
installations, the power supply cord must
have four. No.-10 copper wires and
match a four-wire receptacle
of NEMA
Type 14-30R. The fourth wire (grounding
conductor)
must be identified with a
green cover or bare copper wire and
the neutral conductor
by a white cover.
Do not use an extension cord with this
laundry center.
Do not connect plua end of power
supply cord into a live receptacle before
connecting
power supply cord to laundry
center terminal block.
Neutral
Grounding
prong
Neutralwire
ah-inch, U .L.-li.,;ted,
(white)
strainreliel
\
_
6
wire (green)
Ring
terminals
Four-Wire Power Supply
Cord
(Mobile
home or other four-wire
iinstallations)
24
F0ur-wire receptacle
(NEMA Type 14-30R)