Error Code/Symptom
001-250-000 (Failed System Board ECC)
001-250-001 (Failed Processor Board ECC) System board
001-292-000 (Core system: failed/CMOS
checksum failed)
005-XXX-000 (Failed Video test)
011-XXX-000 (Failed COM1 Serial Port
test)
011-XXX-001 (Failed COM2 Serial Port
test)
014-XXX-000 (Failed Parallel Port test)
015-XXX-001 (USB interface not found,
board damaged)
015-XXX-198 (USB device connected
during USB test)
020-XXX-000 (Failed PCI Interface test)
030-XXX-000 (Failed Internal SCSI
interface test)
035-XXX-099
035-XXX-S99 (Failed RAID test on PCI slot
S, check System Error Log before replacing
a FRU)
035-XXX-SNN (Check System Error Log
before replacing a FRU, NN = SCSI ID of
failing fixed disk)
035-253-S99 (RAID adapter initialization
failure)
089-XXX-001 (Failed Microprocessor test)
089-XXX-002 (Failed Optional
Microprocessor test)
106
IBM xSeries 225 Type 8647: Hardware Maintenance Manual and Troubleshooting Guide
FRU/Action
System board
Load BIOS code defaults and rerun test.
1. Video adapter
2. System Board
1. Check loopback plug connected to externalized serial port.
2. Check cable from externalized port to system board. Should
connect to Serial Port A on the system board (J52).
3. System Board.
1. Check loopback plug connected to externalized serial port.
2. Check cable from externalized port to system board. Should
connect to Serial Port B on the system board (J51).
3. System Board.
System board
System board
1. Remove USB devices from USB1 and USB2.
2. System Board
.
System board
System board
1. Integrated RAID function on system board is damaged.
2. No RAID adapters were found.
3. If adapter is installed re-check connection.
1. RAID Adapter
2. SCSI Backplane
3. Cable
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
1. ServeRAID Adapter in slot S is not configured properly. Obtain the
basic and extended configuration status and refer to the ServeRAID
Hardware Maintenance Manual for more information.
2. Cable.
3. SCSI Backplane.
4. Adapter.
1. Microprocessor 1
2. System Board
1. Microprocessor 2
2. System Board

Advertisement