IBM 84875MU User Manual page 94

Type 8482 and 8487
Table of Contents

Advertisement

Note: See Chapter 8, "Parts listing, Type 8482 and 8487," on page 99 to determine which components are
replaceable by the customer (CRU), and which components must be replaced by a field service technician (FRU).
Error code/symptom
035-253-s99
(RAID adapter initialization failure)
035-XXX-099
(No adapters were found.)
035-XXX-s99
(Failed RAID test on PCI slot s. s = number
of failing PCI slot.)
035-XXX-snn
(s = number of failing PCI slot, nn = SCSI
ID of failing fixed disk.)
089-XXX-001
(Failed microprocessor test)
089-XXX-002
(Failed optional microprocessor test)
201-XXX-0nn
(Failed memory test.)
201-XXX-999
(Multiple DIMM failure, see error text)
202-XXX-001
(Failed system cache test)
202-XXX-002
(Failed system cache test)
206-XXX-000
(Failed diskette drive test)
215-XXX-000
(Failed IDE CD-ROM drive test)
84
xSeries 206 Type 8482 and 8487: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. ServeRAID adapter in slot s is not configured properly. Obtain
the basic and extended configuration status and see the ServeRAID
Hardware Maintenance Manual for more information.
2. Cable.
3. Adapter.
v If adapter is installed re-check connection.
1. RAID adapter
2. Cable
3. System board
v Hard disk drive with SCSI ID nn on RAID adapter in PCI slot s.
1. Verify microprocessor 1 is installed and seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 1.
4. System board.
1. Verify microprocessor 2 is installed and seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 2.
4. System board.
1. DIMM Location slots 1-4 where nn = DIMM location.
Note: nn 1=DIMM 1; 2=DIMM 2; 3=DIMM 3; 4=DIMM 4.
2. System board.
1. See error text for failing DIMMs.
2. System board.
1. Verify microprocessor 1 is installed and seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 1.
4. System board.
1. Verify microprocessor 2 is installed and seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 2.
4. System board.
1. Rerun the test using another diskette.
2. Cable.
3. Diskette drive.
4. System board.
1. Rerun the test using another CD-ROM.
2. CD-ROM drive cables.
3. CD-ROM drive.
4. System board.

Advertisement

Table of Contents
loading

Table of Contents