IBM 84875MU User Manual page 91

Type 8482 and 8487
Table of Contents

Advertisement

Note: See Chapter 8, "Parts listing, Type 8482 and 8487," on page 99 to determine which components are
replaceable by the customer (CRU), and which components must be replaced by a field service technician (FRU).
Error code/symptom
189
(An attempt was made to access the
server with invalid passwords)
201
(Memory test error.) If the server does not
have the latest level of BIOS installed,
update the BIOS to the latest level and run
the diagnostic program again.
289
(DIMM disabled by POST or user)
301
(Keyboard or keyboard controller error)
303
(Keyboard controller error)
602
(Invalid diskette boot record)
604
(Diskette drive error)
662
(Diskette drive configuration error)
962
(Parallel port error)
1162
(Serial port configuration conflicts)
1762
(Hard disk configuration error)
1800
(No more hardware interrupts available for
PCI adapter)
FRU/action
v Run the Configuration/Setup Utility program, and enter the
administrator password.
1. DIMM
2. System board
1. Run the Configuration/Setup Utility program, if the DIMM was
disabled by the user.
2. Disabled DIMM, if not disabled by user.
3. System board
1.
Keyboard
2. System board
v System board
1. Diskette
2. Diskette drive
3. Cable
4. System board
1. Run the Configuration/Setup Utility program.
2. Diskette drive.
3. Cable.
4. System board.
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Disconnect the external cable on the parallel port.
2. Run the Configuration/Setup Utility program.
3. System board.
1. Run the Configuration/Setup Utility program and ensure that the
IRQ and I/O port assignments needed by the serial port are
available.
2. If all interrupts are being used by adapters, remove an adapter or
force other adapters to share an interrupt.
1. Hard disk drive.
2. Hard disk drive cables.
3. Run the Configuration/Setup Utility program.
4. SCSI backplane.
5. System board.
1. Run the Configuration/Setup Utility program.
2. Remove adapter.
Chapter 7. Symptom-to-FRU index
81

Advertisement

Table of Contents
loading

Table of Contents