IBM 84875MU User Manual page 47

Type 8482 and 8487
Table of Contents

Advertisement

v You do not have to turn off the server to install hot-swap drives in the hot-swap
drive bays; however, you may need to restart the server so that the hot-swap
drive will be recognized and reconfigured.
v Install hot-swap hard disk drives in this sequence: bay 7, bay 6, and bay 5.
v If the server has an optional RAID adapter, see the documentation that comes
with the adapter for instructions for installing a hard disk drive.
v Each hot-swap drive has two LEDs: the hard disk drive activity LED and the hard
disk drive status LED. When the green hard disk drive activity LED is flashing, it
indicates that the controller is accessing the hard disk drive. When the amber
hard disk drive status LED is lit continuously, it indicates that the drive is faulty
and must be replaced.
The server hot-swap bays are connected to a hard disk drive backplane. This
backplane is the printed circuit board behind the bay. The backplane controls the
SCSI IDs for the hot-swap drives.
The following illustration shows the location of the components on the
hot-swap-drive backplane as seen from the front of the server drive cage.
The following illustration shows the rear connectors on the hot-swap-drive
backplane as seen from the rear of the server drive cage.
Hard disk
drive activity
LED (green)
Hard disk
drive status
LED (amber)
SCSI hot-swap
hard disk drive
connector
SCSI cable
connector
SCSI power
cable connector
2
I C cable
connector
Chapter 4. Installing options
37

Advertisement

Table of Contents
loading

Table of Contents