Dacor REMP16 Planning Manual

Dacor REMP16 Planning Manual

Remote blowers
Hide thumbs Also See for REMP16:

Advertisement

19" (483mm)
17 3/8" (441mm)
9 1/2" (241mm)
(191mm)
C L C L
Power Supply
Conduit Hole
24 1/4"
(616mm)
Intake Collar
25 1/2"
(648mm)
Cutout Location
11"W x 12 5/8"H
(279mm X 321mm)
Discharge
REMP3 ovERALL DIMENsIoNs
26" (660mm)
24 1/4" (616mm)
13 1/8"
(333mm)
9 1/2"
(241mm)
C L C L
Power Supply
Conduit
Location
32 1/4"
(819mm)
Intake Collar
33 1/2"
Cutout Location
(851mm)
13"W X 16 5/8"H
(330mm X 422mm)
Discharge
REMP16 ovERALL DIMENsIoNs
Electrical Supply
Model No.
Requirments
REMP3
Refer to raised
vent or hood
specifications
REMP16
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
REMP3, REMP16
Remote Blowers
Revised
01/30/09
7 1/2"
2 1/8"
(92mm)
3 5/8"
(92mm)
C L
9 1/4"
(235mm)
C L
Mounting
Flange
(Top & Side Views)
2 1/8"
(54mm)
3 5/8"
(92mm)
C L
12 1/4"
(311mm)
C L
Mounting
Flange
(Top & Side Views)
Maximum Duct
Length
Refer to raised
vent or hood
specifications
+/- 1/16" (+/- 1.6mm) unless otherwise stated
7 15/16"
(202mm)
5 13/16"
(148mm)
8" Nom.
(203mm)
Intake Collar
Discharge
1.
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
2.
This appliance must be installed in accordance with the
accompanying installation instructions.
11 1/2"
(292mm)
9 9/16"
(243mm)
10" Nom.
(254mm)
Intake Collar
Discharge
Total Connected
Load
Blower Rating*
600 CFM (nominal)
120 Vac, 3.8 Amp
620.5 CFM (actual)
1000 CFM (nominal)
120 Vac, 2.7 Amp
994.8 CFM (actual)
* At 0" static pressure
Specifications are subject to change without notice.
See installation instructions for additional details.
PLANNING
GUIDE
1/3
WARNING
Approximate
Shipping Weight
Finish
35 lbs.
Galvanized
(may be painted)
55 lbs.
9.3

Advertisement

loading

Summary of Contents for Dacor REMP16

  • Page 1 Intake Collar Intake Collar 33 1/2" Mounting Cutout Location (851mm) Flange 13”W X 16 5/8”H (330mm X 422mm) Discharge Discharge REMP16 ovERALL DIMENsIoNs (Top & Side Views) Electrical Supply Maximum Duct Total Connected Approximate Model No. Requirments Length Load Blower Rating*...
  • Page 2 REMP3, REMP16 PLANNING Remote Blowers Revised GUIDE 01/30/09 REMP3 Blower Performance Airflow CFM (Cubic feet/minute) REMP16 Blower Performance 1000 Airflow CFM (Cubic feet/minute) Web: http://www.Dacor.com Specifications are subject to change without notice. Corporate Phone: 800-793-0093 See installation instructions for additional details.
  • Page 3 REMP3, REMP16 PLANNING Remote Blowers Revised GUIDE 06/11/08 +/- 1/16” (+/- 1.6mm) unless otherwise stated NOTE: The REMP chassis may be rotated to clear Wiring/Conduit obstructions. 15” (381mm) min. clearance must be maintained from the air discharge to any obstruction. When mounting in a horizontal...

This manual is also suitable for:

Remp3