Installation Instructions
Remote Blowers
Models: REMP3, REMP16
Suitable for use in a household cooking area.
Suitable for use with solid state controls.
To complete this blower, a Dacor
®
hood assembly or Dacor downdraft vent
must be purchased separately. See the hood or downdraft vent installation
instructions to determine suitability.
Part No. 65265 Rev. J

Advertisement

Table of Contents
loading

Summary of Contents for Dacor REMP3

  • Page 1 Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor ® hood assembly or Dacor downdraft vent must be purchased separately. See the hood or downdraft vent installation instructions to determine suitability.
  • Page 2: Table Of Contents

    Dacor Distinctive Service (for repairs under warranty only) Phone: (800) 793-0093 ex. 2822 (U.S.A. and Canada) Monday — Friday 6:00 . to 5:00 . Pacific Time All specifications subject to change without notice. Dacor assumes no liability for changes to specifications. © 2008 Dacor, all rights reserved.
  • Page 3: Important Safety Instructions

    WARNING ating this or any other appliance. • Always contact the Dacor Customer Service Team Hazards or unsafe practices that COULD result in severe about problems and conditions that you don’t under- personal injury or death.
  • Page 4: General Safety Precautions

    • Install or locate this appliance only in accordance Do not allow foreign objects, such as cigarettes or with these installation instructions and the Dacor napkins, to be sucked into the vent holes. hood or downdraft vent installation instructions. •...
  • Page 5: Product Dimensions

    24 1/4” (61.6 cm) Intake collar Mounting 25 1/2” Intake collar flange (64.8 cm) Discharge Discharge REMP3 26” (66.0 cm) 11 1/2” 24 1/4” (61.6 cm) (29.2 cm) 9 9/16” 13 1/8” (24.3 cm) (33.3 cm) 9 1/2” (24.1 cm) 3 5/8”...
  • Page 6: Installation Requirements

    There is a 7/8” Figure 1: Required Mounting Surface Dimensions electrical access hole on the bottom of the blower. Blower Location and Mounting Dimension REMP3 REMP16 • Install the blower in a location that allows it to be 19” (48.3 cm) 26”...
  • Page 7: Installation Preparation

    NOTE: Range hood installations with a very short duct run are not recommended due to noise. When a range hood installation can accommodate a short duct run, Dacor instead recommends installation of a range hood with an integral blower instead of using a REMP Blower series blower.
  • Page 8: Installation Instructions

    Installation Instructions 2. Remove the blower’s top cover by removing the screws WARNING around the edge that hold it in place. • If the electrical service provided does not meet the power requirements for the hood/downdraft vent and the blower combined, do not continue with the instal- lation.
  • Page 9: Verifying Proper Operation

    BLUE wire from the blower wiring har- 0093 ex. 2822. Do not attempt to repair the unit yourself. ness connected to it. Dacor is not responsible for the costs required to correct problems caused by a faulty installation. Wires...
  • Page 10: Technical Data

    REMP Series Blower Ratings Model Nominal Actual Number Rating* Rating* REMP3 600 CFM 620.5 CFM REMP16 1000 CFM 994.8 CFM * At 0” static pressure REMP3 Blower Performance REMP16 Blower Performance 1000 Airflow CFM (Cubic feet/minute) Airflow CFM (Cubic feet/minute)
  • Page 12 Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com...