Dacor REMP3 Installation Instructions Manual

Dacor REMP3 Installation Instructions Manual

Remote blowers
Hide thumbs Also See for REMP3:

Advertisement

Installation
Instructions
Remote Blowers
Models: REMP3, REMP16
Suitable for use in a household cooking area.
Suitable for use with solid state controls.
To complete
this blower, a Dacor ® hood assembly or Dacor raised vent must
be purchased separately. See the hood or raised vent installation instructions
to determine suitability.
Part No. 65265
Rev. G

Advertisement

Table of Contents
loading

Summary of Contents for Dacor REMP3

  • Page 1 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor ® hood assembly or Dacor raised vent must be purchased separately. See the hood or raised vent installation instructions to determine suitability.
  • Page 2: Table Of Contents

    Dacor Distinctive Service (for repairs under warranty only) Phone: (877) 337-3226 Monday -- Friday 6:00 A.M.to 4:00 P.M.Pacific Time All specifications subject to change without notice. Dacor assumes no liability for changes to specifications. © 2008 Dacor, all rights reserved.
  • Page 3: Important Safety Instructions

    WARNING • Always contact the Dacor Customer Service Team Hazards 0r Unsafe practices that COULD result in severe about problems and conditions that you don't under- personal injury or death.
  • Page 4: General Safety Precautions

    Do not allow foreign objects, such as cigarettes or Install or locate this appl ante only in accordance napkins, to be sucked into the vent holes. with these installation instructions and the Dacor Tape all duct joints securely to prevent combus- hood or downdraft vent installation instructi0nsl...
  • Page 5: Product Specifications

    Hole/_.. 8" Nom. (203mm) 24 1/4" (616mm) Intake Collar 25 1/2" Mounting Intake Collar (648mm) Flange Discharge Discharge REMP3 26" (660mm) 11 1/2" .q_24 1/4" (616mm)-_- 9 9/16" (292mm) (243mm) (333mm) 9 1/2" (241 mm) 13 1/8" 3 5/8" (92mm) Power Supply _'";'...
  • Page 6: Installation Planning And Preparation

    Installation Planning Electrical Supply Requirements The power for this blower is supplied via 1/2" 3-wire System Layout wiring/conduit (not included) by an approved Dacor hood or raised vent. The wiring/conduit is installed WARNING between the hood or raised vent and the blower and shall be terminated on each end by a 1/2"...
  • Page 7: Installation Preparation

    -"_4_-:" % : Roof Cu rb -_"" "_:: ._.-.'-M """-"" Model Number Approximate Shipping Weight _ ':°:: _"? :: '°"?i_,_j_ REMP3 35 Ibs. REMP16 55 Ibs. _._,_-..: :._:--. ;_ _.._-. _ 9:-_-': • _:_-. •:.._.:.-:..- ._:.:_..,_., " _?.:: ::-. Weight Table...
  • Page 8: Installation Instructions

    Remove the blower's top cover by removing the screws WARNING around the edge that hold it in place. • If the electrical service provided does not meet the power requirements for the hood/raised vent and the blower combined, do not continue with the instal- lation.
  • Page 9: Verifying Proper Operation

    Dacor Distinctive Service at (877) 337- minal (see Figure 9). Tighten the terminal screw firmly 3226. Do not attempt to repair the unit yourself. Dacor is into place. IMPORTANT: The L2 (hot) terminal on the not responsible for the costs required to correct problems blower has the BLUE wire from the blower wiring har- caused by a faulty installation.
  • Page 10: Technical Data

    Actual Number Rating* Rating* REMP3 600 CFM 620.5 CFM REMP16 1000 CFM 994.8 CFM At 0" static pressure REMP3 Blower Performance REMP16 Blower Performance _- 5.0 _- 2.5 .4--, -- 4.0 _- 2.0 =o1.5 c° 3.0 _ 2.o o 1.0 o 0.5...
  • Page 11 The Life of the Kitchen? Dacor • 1440 Bridge Gate Drive, Diamond Bar, CA 91765 • Tel: (800) 793-0093 • FAX: (626) 403-3130 • www.Dacor.com...