PDG-DWL100 Basic Serial Command Specifications
7.8

Temp Read Command

COMMAND
"CR6" [CR]
Get the temperature information inside projector
Detail
With more than one temperature sensors installed in the projector, it is possible
to get all temperatures at once.
Acceptable
Response
Unacceptable
7.9

Lamp Mode Read Command

COMMAND
"CR7" [CR]
Get lamp mode status.
Detail
For 1 lamp projector, get if it is lighting or not.
Acceptable
Response
Unacceptable
"%1" [CR]
%1 = temperature at Sensor 1
Temperature data is expressed as "00.0".
When the temperature goes under 0, the first character is "-" like
"-05.5" [CR].
%1
When no temperature data returns due to hardware problems
%2
the first character is "E" like" E00.0" [CR].
With more than one temperature sensors installed, the projector
returns the values in series.
"_31.5" [CR]
Each sensor data follows in sequence with one space between
each of them.
"?" [CR]
"%1" [CR]
"00" [CR]=Light is out.
%1
"01" [CR]=Light is on.
"?" [CR]
19 / 19