Input Mode Read Command; Lamp Time Read Command; Setting Read Command; Temp Read Command - Sanyo PLC-WL2500A Manual

Basic serial command specifications
Hide thumbs Also See for PLC-WL2500A:
Table of Contents

Advertisement

PLC-WL2500A/WL2501A/ WL2503 A Basic Serial Command Specifications

7.5. Input Mode Read Command

Command
"CR1" [CR]
Detail
Get the selected Input No.
Acceptable
Response
Unacceptable

7.6. Lamp Time Read Command

Command
"CR3" [CR]
Get the total lamp running hours (Not actual lamp used hour, but Eco mode
Detail
corresponding value).
Acceptable
Response
Unacceptable

7.7. Setting Read Command

Command
"CR4" [CR]
Detail
Get screen setting status such as Ceiling / Rear.
Acceptable
Response
Unacceptable

7.8. Temp Read Command

Command
"CR6" [CR]
Get the temperature data inside the projector.
Detail
With some temperature sensors installed in the projector, it is possible to get all
the temperature at once.
Acceptable
Response
Unacceptable
"%1" [CR]
"1" = Computer 1 is selected
"2" = Computer 2 is selected
%1
"3" = HDMI is selected
"4" = Video is selected
"5" = S-video is selected
"?" [CR]
"%1" [CR]
Shows the time period with 5 digits numbers.
%1
Exampleÿ "00410"[CR] ÿ e ÿ e ÿ e ÿ e shows 410 hours
"?" [CR]
"%1" [CR]
"11"[CR] = Normal Screen Setting
"10"[CR] = Picture is top/bottom reversed.
(Status: Rearÿ Ceiling ON)
%1
"01"[CR] = Picture is left/right reversed. (Status: Rear ON)
"00"[CR] = Picture is top/bottom and left/right reversed.
(Status: Ceiling ON
"?" [CR]
"%1_%2_%3" [CR]
%1ÿ Temperature of sensor 1
%2ÿ Temperature of sensor 2
%3ÿ Temperature of sensor 3
Temperature data is shown as "00.0".
When the temperature goes down to -, the first character
%1
becomes "-" instead of a space, like "-05.5" [CR].
%2
When no temperature data can be returned due to hardware
%3
problems, the first character becomes "E" like"E00.0" [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
"_31.5 _ _35.2 _ _33.4"[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.
"ÿ "[CR]
24/25
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wl2501aPlc-wl2503a

Table of Contents