Dell PowerVault NX3500 Hardware Owner's Manual page 41

Powervault nx3500 systems
Hide thumbs Also See for PowerVault NX3500:
Table of Contents

Advertisement

Table 1-4. System Messages
Message
Plug & Play
Configuration
Error.
Quad rank DIMM
detected after
single rank or
dual rank DIMM in
socket.
Read fault.
Requested sector
not found.
SATA Port x
device not
found.
(continued)
Causes
Error encountered in
initializing PCIe device;
faulty system board.
Invalid memory
configuration.
The operating system cannot
read from the hard drive,
optical drive, or USB device,
the system could not find a
particular sector on the disk,
or the requested sector is
defective.
There is no device connected
to the specified SATA port.
Corrective Actions
Install the NVRAM_CLR
jumper in the clear position
(pins 1 and 3) and reboot the
system. See Figure 5-1 for
jumper location. If the
problem persists,
see "Troubleshooting an
Expansion Card" on
page 101.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 67.
Replace the optical medium,
USB medium, or USB
device. Ensure that the USB
cables, SAS/SATA backplane
cables, or optical drive cables
are properly connected.
See "Troubleshooting an
Optical Drive" on page 99, or
"Troubleshooting a Hard
Drive" on page 100 for the
appropriate drive(s) installed
in your system.
Information only.