Table 1-4. System Messages
Message
Current boot mode
is set to UEFI.
Please ensure
compatible
bootable media is
available. Use
the system setup
program to change
the boot mode as
needed.
Embedded NICx and
NICy:
OS NIC=<ENABLED
|DISABLED>,
Management
Shared NIC=
<ENABLED
|DISABLED>
Gate A20 failure. Faulty keyboard controller;
Invalid
configuration
information -
please run SETUP
program.
Invalid PCIe card
found in the
Internal_Storage
slot!
Keyboard fuse has
failed.
38
About Your Solution
(continued)
Causes
The system failed to boot
because UEFI boot mode is
enabled in BIOS and the
boot operating system is non-
UEFI.
The OS NIC interface is set
in BIOS. The Management
Shared NIC interface is set
in management tools.
faulty system board.
An invalid system
configuration caused a
system halt.
The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage
controller slot.
Overcurrent detected at the
keyboard connector.
Corrective Actions
Ensure that the boot mode is
set correctly and that the
proper bootable media is
available.
Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
"Troubleshooting a NIC" on
page 93.
See "Getting Help" on
page 113.
Run the System Setup
program and review the
current settings.
Remove the PCIe expansion
card and install the
integrated storage controller
in the dedicated slot. See
"Getting Help" on page 113.
See "Getting Help" on
page 113.

Advertisement

Table of Contents
loading

Table of Contents