Table 1-3. LCD Status Messages
Code
Text
E1714
Unknown error.
Review & clear
SEL.
E171F
PCIe fatal
error on Bus
## Device ##
Function ##
E1810
Hard drive ##
fault. Review
& clear SEL.
E1812
Hard drive ##
removed. Check
drive.
E1920
iDRAC6 Upgrade
Failed.
E1A14
SAS cable A
failure. Check
connection.
(continued)
Causes
The system BIOS has
determined there has
been an error in the
system, but is unable to
determine its origin.
The system BIOS has
reported a PCIe fatal
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
The specified hard drive
has experienced a fault.
The specified hard
drive has been removed
from the system.
iDRAC6 upgrade has
failed.
SAS cable A is missing
or bad.
Corrective Actions
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 113.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting an
Expansion Card" on
page 101.
See "Troubleshooting a
Hard Drive" on page 100.
Information only.
See "Getting Help" on
page 113.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 113.
About Your Solution