Table 1-4. System Messages
Message
Memory tests
terminated by
keystroke.
MEMTEST lane
failure detected
on x.
No boot device
available.
No boot sector on
hard drive.
No timer tick
interrupt.
PCIe Training
Error: Expected
Link Width is x,
Actual Link Width
is y.
40
About Your Solution
(continued)
Causes
POST memory test was
terminated by pressing the
spacebar.
Invalid memory
configuration. Mismatched
memory modules are
installed.
Faulty or missing optical
drive subsystem, hard drive,
or hard drive subsystem, or
no bootable USB key
installed.
Incorrect configuration
settings in System Setup
program, or no operating
system on hard drive.
Faulty system board.
Faulty or improperly
installed PCIe card in the
specified slot.
Corrective Actions
Information only.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 67.
Use a bootable USB key,
optical drive, or hard drive.
If the problem persists,
see "Troubleshooting an
Optical Drive" on page 99,
and "Troubleshooting a Hard
Drive" on page 100.
Check the hard drive
configuration settings in the
System Setup program.
If necessary, install the
operating system on your
hard drive. See your
operating system
documentation.
See "Getting Help" on
page 113.
Reseat the PCIe card in the
specified slot number.
See "Troubleshooting an
Expansion Card" on
page 101. If the problem
persists, see "Getting Help"
on page 113.

Advertisement