STEP 2.Remove hold-down screw and
terminal block c over.
Hold-down screw
\
STEP
4a. Place the hook-shaped
end
of the wire over the terminal
block screw.
The open
side of the hook should
face
to the right. Squeeze
hook end of wire
together
to form a loop.
Terminal
block cover
STEP
3. Attach
a _-inch,
U.L.-Iisted
strain
relief to the hole below terminal
block
opening.
Strain
relief should
have a tight
fit with dryer cabinet
and be in a horizon-
tal position.
Put the direct wire cable
through
the strain
relief.
STEP
4. Loosen
or remove
terminal
block
screws.
Connect
the neutral
wire (white or
center)
of direct wire cable under the cen-
ter screw
of the terminal
block.
External ground
connector
STEP
5. Connect
the other two wires
to
outer terminal
block screws
using the
same
method(s)
described
in STEP 4a.
Securely
tighten
all electrical
connections.
STEP
6. Tighten
the strain relief screws.
STEP
7. insert
tab of terminal
block cover
into slot of the dryer rear panel.
Secure
cover with hold-down
screw.
If local
codes
do not permit
the
connection
of a frame-grounding
conductor
to the neutral
wire,
see the instructions
on page
18.
Otherwise,
proceed
with
Installation
on page
24.
Center silver-colored
terminal
block screw
Neutral wire
(white)
Neutral grounding
/
wire (green/yellow)
K-inch,
U.L.-listed
strain relief
3-Wire
Connection
with Direct Wire
and Frame-Grounding
Conductor
I7

Advertisement

Table of Contents
loading

This manual is also suitable for:

27-inch wide electric dryers

Table of Contents