STEP
3. Attach
a _-inch,
U.L.-listed
strain
relief to the hole below
terminal
block
opening.
Strain
relief should
have a tight
fit with dryer cabinet
and be in a horizon-
tal position.
Put the direct wire cable
through
the strain relief.
STEP
6. Place the hook-shaped
end of
the wire over the terminal
block screw.
The open
side of the hook should
face
to the right. Squeeze
hook end of wire to-
gether
to form a loop.
STEP
4. Remove
the center
terminal
block screw. Remove
the neutral
ground-
ing wire (green/yellow
wire) from external
grounding
screw.
External ground
Center silver-colored
connector
terminal
block screw
Green/yellow
wire
of harness
STEP
5. Connect
neutral
grounding
wire
and the neutral
wire (white or center)
of
direct wire cable under the center
screw
of terminal
block.
STEP
7. Connect
the other two wires
to outer terminal
block screws.
Use the
same
method
described
in STEP
6.
STEP
8. Connect
the direct wire cable
(bare) grounding
wire to the external-
grounding
conductor
screw.
Securely
tighten
all electrical
connections.
STEP
9. Tighten
the strain
relief screws.
STEP
10. insert
tab of terminal
block
cover
into slot of the dryer rear panel.
Secure
cover with hold-down
screw.
External
ground
connector
\
\
Neutral wire
Center silver-colored
terminal block screw/(white)
/
//
Green wire
/
of power supply
cord or bare
copper wire
¾-inch, U.L.-listed
strain relief
Neutral
grounding
wire (green/yellow)
4-Wire
Connection
with
Direct
Wire
and Frame-Grounding
Conductor
23