Kenmore 11069912990 Owner's Manual And Installation Instructions page 19

27-inch wide electric dryers
Table of Contents

Advertisement

III. MAKE FOUR-WIRE
ELECTRICAL
CONNECTION
TO RECEPTACLE
Use a 4-wire power supply cord:
Fire Hazard
Use a new UL approved
30 ampere
power
supply
cord.
Use a UL approved
strain
relief.
Disconnect
power
before
making
electrical
connections.
Connect
neutral wire (white
or center
wire) to center terminal
(silver).
Ground
wire (green
or bare wire)
must
be connected
to green ground
connector.
Connect
remaining
2 supply
wires to
remaining
2 terminals
(gold).
Securely
tighten all electrical
connections.
Failure to do so can result in death,
fire, or electrical
shock.
Neutral
Local codes
may permit
the use of
a U.L.-listed,
120/240-volt
minimum,
30-ampere,
dryer power supply
cord kit
(pigtail).
Power supply
cord should
be
type SRD or SRDT
and be at least four
feet long. The wires
that connect
to the
dryer must end with ring terminals
or
spade terminals
with upturned
ends.
For mobile
homes
or other four-wire
installations,
the power
supply
cord must
have four, No.-10
copper
wires
and match
a four-wire
receptacle
of NEMA
Type 14-
30R. The fourth wire (grounding
conduc-
tor) must be identified with a green
cover
or bare copper
wire and
the neutral
conductor
by a white
cover.
Do not use an extension
cord with
this dryer.
Do not connect
plug end of power
supply
cord into a live receptacle
before
connecting
power
supply
cord to dryer
terminal
block.
\,
Grounding
prong
Neutral
_/4-inch, U.L.-listed
wire (white)
strain relief
wire
(green)
Ring
terminals
Four-Wire
Power Supply
Cord
(Mobile
home
or other
four-wire
installations)
Four-wire receptacle
(NEMA Type 14-30R)
I9

Advertisement

Table of Contents
loading

This manual is also suitable for:

27-inch wide electric dryers