Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
www.tektronix.com
*P075091201*
075091201

Advertisement

loading
Need help?

Need help?

Do you have a question about the MTS4UP QB2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tektronix MTS4UP QB2

  • Page 1 075-0912-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service. www.tektronix.com *P075091201* 075091201...
  • Page 2 Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material.
  • Page 3 Table of Contents General Safety Summary ........Service Safety Summary .
  • Page 4 Table of Contents MTS4UP MTS400 Series Upgrade Kits...
  • Page 5 General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. To Avoid Fire or Use Proper Power Cord.
  • Page 6 General Safety Summary Terms in this Manual These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
  • Page 7 Only qualified personnel should perform service procedures. Read this Service Safety Summary, and the General Safety Summary located in the RSA6100A Service manual (Tektronix part number 071- -1914- -xx) before performing any service procedures. Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present.
  • Page 8 Service Safety Summary MTS4UP MTS400 Series Upgrade Kits...
  • Page 9 Kit Description This document provides instructions for performing hardware and/or software and option key upgrades on the following Tektronix products: H MTS400 Series MPEG Test System H MTS4SA MPEG Test System Upgrade Kits Covered by These Instructions H MTS4UP UPG - - This kit provides a software upgrade for your MTS4xx.
  • Page 10 Series instrument. This kit may only be combined with the MTS4UP GBE kit. H MTS4UP QB2 - - This kit adds a QAM B interface to your MTS400 Series instrument. This kit may only be combined with the MTS4UP GBE kit.
  • Page 11 Kit Description Kit Parts Lists MTS4UP UPG The MTS4UP UPG software upgrade kit contains these parts: Quantity Part number Description 1 Each 020-2654-xx DOCUMENTATION KIT; ENGLISH GETTING STARTED MANUAL W/DOCUMENTATION CD-ROM; MTS400 SERIES 1 Each 063-3814-xx SOFTWARE PKG; APPLICATION INSTALL CD-ROM; MTS400 SERIES 1 Each IMPORTANT DOCUMENTS ENVELOPE, WITH PRODUCT...
  • Page 12 Kit Description MTS4UP CF The MTS4UP CF upgrade kit contains all the parts listed for the MTS4UP UPG software upgrade kit, and these additional parts: Quantity Part number Description 1 Each 672- - 1780- - xx TESTED SET, BASE BAND AND COFDM; SAFETY CONTROLLED 1 Each 174- - 5336- - xx...
  • Page 13 Kit Description MTS4UP QB2 The MTS4UP QB2 upgrade kit contains all the parts listed for the MTS4UP UPG software upgrade kit and these additional parts: Quantity Part number Description 1 Each 672- - 1782- - xx TESTED SET, BASE BAND AND QB2; SAFETY...
  • Page 14 Kit Description MTS4UP MTS400 Series Upgrade Kits...
  • Page 15 These instructions are for personnel who are familiar with servicing the product. If you need further details for disassembling or reassembling the product, refer to the appropriate product manual. Contact your nearest Tektronix, Inc., Service Center or Tektronix Factory Service for installation assistance.
  • Page 16 Upgrade Instructions Figure 1: InstallShield Wizard welcome screen 5. Allow the installation process to proceed. The average installation time is approximately five minutes. NOTE. A number of dialog boxes are displayed during the installation process. Normally, no user intervention is required. 6.
  • Page 17 7. Select the Yes, I want to restart my computer now option, and then click Finish. The instrument or PC will shut down and then restart. 8. When the unit has completed the start-up process, the Tektronix Option Update wizard will start automatically (see Figure 3).
  • Page 18 Note that the Serial Number of the software key has been detected, but the Key Status is invalid because no KeyString has been entered. 9. In the Tektronix Option Update dialog box, enter the Option Key String, found on the Product Option Key label supplied with these upgrade instructions, in the Key String field.
  • Page 19 Upgrade Instructions Figure 4: Tektronix Option Update Wizard - Complete 10. Inspect and verify the list of licensed options (see Figure 24). 11. Close the Tektronix Option Update wizard. 12. Peel the backing off of the Product Option Key label and apply it to the instrument rear panel, as shown in Figure 5.
  • Page 20 Verify Operation To verify operation of the upgraded applications, open and close each installed application in turn. If any licensed application fails to open correctly, contact your Tektronix representative. Upgrading Hardware Use the following procedure to install any of the hardware upgrades.
  • Page 21 Upgrade Instructions 2. Disconnect any cables from the rear panel. Note the location of any cables for reinstallation. 3. Install the protective cover on the front of the instrument and place the cabinet on the working surface with the rear panel facing up. 4.
  • Page 22 If you are installing an MTS4UP GBE Gigabit Ethernet input upgrade, with or without any of the other hardware upgrades, continue with the process below. If you are installing an MTS4UP CF, MTS4UP EP, MTS4UP QB2, or MTS4UP VS upgrade without an MTS4UP GBE, go to page 15.
  • Page 23 Upgrade Instructions 4. Press down firmly to engage the module into the connector (see Figure 7). Figure 7: Gigabit Ethernet module in place 5. Secure the Gigabit Ethernet module in place, using the screws that held the slot 2 blank panel in place. 6.
  • Page 24 Upgrade Instructions Figure 8: Hardware upgrade module installed in slot 4 4. Secure the hardware upgrade module in place, using the screws that held the slot 4 and 5 blank panels in place. 5. Attach the 2x5 connector end of the interface cable provided in the kit to the COM2 connector on the controller board in slot 11, as shown in Figure 9.
  • Page 25 Upgrade Instructions Figure 9: Interface cable connected to controller board Figure 10: Interface cable connected to the hardware upgrade module MTS4UP MTS400 Series Upgrade Kits...
  • Page 26 Upgrade Instructions Replace the Cabinet Replace the circuit board retaining plate and the cabinet by reversing the Accessing the Module Bay instructions on page 12. CAUTION. To prevent damage to the instrument, make sure that the internal cables do not catch when you slide the cabinet back onto the chassis. Make sure that the edges of the cabinet go under the retaining tabs around the front of the chassis.
  • Page 27 Upgrade Instructions Restore the Operating System After installing the hardware upgrade, you must restore the operating system to install the new application software and drivers required for the hardware. CAUTION. To avoid losing access to your licensed applications, you must use the MTS400 Series system Recovery media supplied with this upgrade kit.
  • Page 28 Upgrade Instructions Figure 11: Operating system recovery application 3. Press the “1” key to begin the system restore process. The Acquiring Device... dialog box will appear briefly and display a progress bar. 4. When the system restore is complete, press any key and then press the “4” key, see Figure 12.
  • Page 29 Upgrade Instructions Figure 12: Restore Complete 5. When prompted, press the “Y” key to reboot the instrument. Remove the DVD from the CD- -ROM drive while the system is rebooting. 6. On startup, the system will prompt you to set up Windows XP. Follow the onscreen procedure, accepting the license agreement and defaults where necessary.
  • Page 30 Upgrade Instructions Figure 13: SCSI drives automatically recognized If drives E and F are not listed in Windows Explorer, complete the following procedure to allow them to be recognized by the system. 1. Open the Windows Disk Management window (Start > Control Panel > Performance and Maintenance >...
  • Page 31 Upgrade Instructions Figure 14: Computer Management - SCSI drives, foreign 2. Right- -click on Disk 0 or Disk 1 and select Import Foreign Disks... from the shortcut menu (see Figure 15). MTS4UP MTS400 Series Upgrade Kits...
  • Page 32 Upgrade Instructions Figure 15: Select Import Foreign Disks... 3. In the Import Foreign Disks dialog box, ensure that the disk group is checked and select OK. See Figure 16. Figure 16: Import Foreign Disks dialog box 4. In the Foreign Disk Volumes dialog box, select OK. See Figure 17. MTS4UP MTS400 Series Upgrade Kits...
  • Page 33 Upgrade Instructions Figure 17: Foreign Disk Volumes dialog box 5. This takes a little time. Wait until the drives appear in the upper window, as shown in Figure 18. Figure 18: SCSI drives manually recognized If the SCSI drives fail to import, follow this procedure: 1.
  • Page 34 Upgrade Instructions 5. Reboot the MTS400 platform. 6. Import the SCSI drives again, using the procedure above, starting on page 22. This completes the MTS400 Operating System Restore Procedure. Close the Computer Management window. You must now upgrade the software, as described in the following procedure.
  • Page 35 Upgrade Instructions Figure 19: InstallShield Wizard welcome screen Figure 20: MTS400 Installation - Setup Type MTS4UP MTS400 Series Upgrade Kits...
  • Page 36 Upgrade Instructions 5. Choose 2. MTS400 PLATFORM and select Next. 6. Allow the installation process to proceed. The average installation time is approximately five minutes. NOTE. A number of dialog boxes are displayed during the installation process. Normally, no user intervention is required. 7.
  • Page 37 12. Select the Yes, I want to restart my computer now option, and then click Finish. The instrument or PC will shut down and then restart. 13. After the unit has completed the start-up process, start the Tektronix Option Update wizard by selecting Start > Programs > Tektronix MTS400 >...
  • Page 38 Note that the Serial Number of the software key has been detected, but the Key Status is invalid because no KeyString has been entered. 14. In the Tektronix Option Update dialog box Key String field, enter the Option Key String, found on the Product Option Key label supplied with these upgrade instructions, and then click Apply.
  • Page 39 Upgrade Instructions Figure 24: Tektronix Option Update Wizard - Complete 16. Close the Option Key Wizard. 17. Peel the backing off of the Product Option Key label and apply it to the instrument rear panel, as shown in Figure 5. If there is already an option key label on the rear panel, paste the new one over the old one.
  • Page 40 3. Start the Tektronix Option Update Wizard (Start > Programs > Tektronix MTS400 > OptionKey Wizard). 4. In the Tektronix Option Update Wizard dialog box, enter the Option Key String, found on the Product Option Key label supplied with these upgrade instructions, in the Key String field.