"counter clockwise rotation". Such kinds of signals are normally gener-
ated by standard encoders.
24
• SCA: scaling factor programming
menu.
This menu allows to scale the input
signals coming from both A and B meas-
uring channels in such a way that they
can be shown on the display as a rate,
a frequency, a period or a speed.
The parameters that allow to scale this
input signals according to the needs
are:
Pu.1
: number of pulses per revolution
of the sensor (proximity switch) con-
nected to channel A . Programmable
value: 1<Pu.1<9999.
PS.1
: Prescaler channel A stated in
the following way: A1*10
b1
.
A1
: 1<A1<9999.
b1
: -9<b1<9.
Pu.2
: number of pulses per revolution
of the sensor (proximity switch) con-
nected to channel B . Programmable
value: 1<Pu.1<9999.
PS.2
: Prescaler channel B stated in
the following way: A2 *10
b2
A2
: 1< A2 < 9999.
b2
: -9 < b2 < 9.