Table of Contents Product Image Frost Protection Table of Contents Power ON/OFF What is a Programmable Holiday Programming Room Thermostat? 23-26 Optional Features Installation Procedure Re-calibrating the Thermostat Mode Select Error Codes Pairing the neoHub Floor Temp Sensor Probe Type Pairing the neoStat V2 29-32 Diagrams...
What is a Programmable Room Thermostat? A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set “On” and “Off” periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
Page 5
The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature –...
Installation Procedure Mount the thermostat at eye level. Read the instructions fully so you get the best from our product. Don’t Do not install near to a direct heat source as this will affect functionality. Do not push hard on the LCD screen as this may cause irreparable damage. The neoStat V2 is designed to be flush mounted and requires a back box of 35mm (minimum depth) to be sunk into the wall prior to installation.
Mode Select This neoStat V2 can either be used as a thermostat or a time clock. Thermostat mode is the default setting. To change between thermostat or time clock modes, follow these steps. • Use the Left / Right keys to scroll to ................
• Once connected to the Heatmiser cloud server, the Link LED will turn GREEN. • Connect your smartphone or tablet device to the same WiFi network as your router. • Download the FREE Heatmiser neoApp from the Apple App Store or Google Play Store and register an account.
• Press the Tick key once again to pair the neoStat to the neoHub ....• The MESH symbol appears flashing on the display. • When the neoStat V2 successfully connects to the neoHub the MESH symbol will be permanently displayed. •...
LCD Display 1. Mesh Symbol - Displayed when connected to the neoHub. 2. Day Indicator - Displays the day of the week. 3. Frost Protection – Displayed when frost protection is enabled. 4. Flame Symbol – Displayed when the thermostat is calling for heat and flashes when optimum start is active.
Temperature Display The neoStat V2 can be configured for different sensor options such as built in air sensor, floor sensor or both. The display will clearly indicate which sensor is being used by showing either “Room Temp” or “Floor Temp” before the actual temperature value. Room Temperature Floor Temperature When the neoStat V2 is set to use both the air &...
Setting the Clock To set the clock, follow these steps. • Use the Left / Right keys to scroll to ................• Press and hold Tick to turn off the display ..............• Use the right arrow key to select CLOCK ............... •...
Comfort Levels Explained The neoStat V2 offers three program mode options; Weekday/Weekend programming, 7 Day programming and 24 Hour programming. There is also the option to use the thermostat as a Non-Programmable thermostat. When thermostats are connected to the mesh network, the program mode for the system is configured by using the neoApp.
Page 17
• Use the Up / Down keys to set the hours ............. • Press Tick to confirm ......................• Use the Up / Down keys to set the minutes ............• Press Tick to confirm ......................• Use the Up / Down keys to set the temperature ..........•...
Temperature Control The Up / Down keys allow you to adjust the set temperature ........When you press either key, you will see the word SET and the desired temperature value. Use the Up / Down keys to adjust the SET value ..... Press Tick to confirm settings and return to the main display ...........
Temperature Hold The temperature hold function allows you to manually override the current operating program and set a different temperature for a desired period. • Use the Left / Right keys to scroll to HOLD..............• Press Tick to confirm selection ....................•...
Locking the neoStat V2 The neoStat V2 has a keypad lock facility. To activate the lock follow these steps. • Use the ‘Left/Right’ keys to scroll to ‘HOLD’ & press for 10 seconds ..The display will show 0000. At this point enter a four digit pin number. •...
Frost Mode Use the Left / Right keys to scroll to the Power Icon ..........The frost icon will toggle ON/OFF each time Tick is pressed ..........In this mode, the neoStat will display the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature (see page 23).
Power On/Off When the flame icon is absent there is no requirement for heating to achieve the set temperature, but the neoStat remains active. To turn the neoStat V2 off completely, scroll to the Power Icon and hold the Tick key for approximately 3 seconds until the display shows SETP &...
Holiday In thermostat mode, the holiday function reduces the set temperature in your home to the frost protection temperature setting (see page 23). The thermostat will maintain this temperature for the duration of the holiday and will then automatically return to the program mode on your return. In time clock mode, the holiday function maintains the timed output as OFF.
Optional Settings Explained THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES NEED NOT BE ADJUSTED. Feature 01 – Pairing To neoHub: This function is used to connect the thermostat to the neoHub. Feature 02 - Switching Differential: This function allows you to increase the switching differential of the thermostat.
Page 25
Feature 07 – Floor Temp Limit: This function is available when mode 06 is set to 03 or 04. You can set a floor limiting temperature between 20-45°C (28°C is the default setting). Note: Air Sensor only MUST NOT be used to control electric under-floor heating. Floor Sensor or Both should be used.
Adjusting the Optional Settings • Use the Left / Right keys to scroll to ................• Press and hold the Tick button for 3 seconds .............. • SETUP will be highlighted, now press the tick key once ......... Feature Number Setting Value •...
Re-calibrating the Thermostat If you need to re-calibrate the thermostat, follow these steps. • Use the Left / Right keys to scroll to the ..........• Press and hold Tick to turn the display OFF ............• Press and hold the Tick and Down keys together for 10 seconds ....•...
Floor Temperature Sensor Probe Type Floor Temperature Sensor Probe Type Floor Temperature Sensor Probe Type The neoStat-e is supplied with a 10K floor sensor probe & is compatible with two other The neoStat-e is supplied with a 10K floor sensor probe & is compatible with two other The neoStat is configured as default for compatibility with 10K sensor probes.
Wiring Diagram - neoStat to Boiler S/L 230VAC TO CONNECT BOILER CONSULT BOILER MAKERS DIAGRAM A2 A1 LIVE 230V SUPPLY IN NEUTRAL SWITCHED LIVE TO BOILER This product must only be installed by a qualified electrician and comply with local installation regulations. Series...
Page 31
Wiring Diagram - neoStat to Boiler Voltfree 230VAC TO CONNECT BOILER CONSULT A2 A1 BOILER MAKERS DIAGRAM VOLT FREE TO BOILER LIVE 230V SUPPLY IN LS & LR ARE NORMALLY THE NEUTRAL ROOM THERMOSTAT CONNECTIONS This product must only be installed by a qualified electrician and comply with local installation regulations.
Page 32
Wiring Diagram - neoStat to Valve 230VAC TO CONNECT BOILER CONSULT RT2 RT1 - A2 A1 BOILER MAKERS DIAGRAM LIVE 230V SUPPLY IN NEUTRAL TO BOILER NEUTRAL LS & LR ARE NORMALLY THE HEATING VALVE ROOM THERMOSTAT CONNECTIONS This product must only be installed by a qualified electrician and comply with local installation regulations.
Page 33
Wiring Diagram neoStat to UH8 and Optional Remote Probe Connections 230VAC A2 A1 FLOOR PROBE (Optional) REMOTE AIR PROBE (Optional) This product must only be installed by a qualified electrician and comply with local installation regulations.
Factory Reset To reset the device to factory default settings, follow these steps: • Use the Left / Right keys to scroll to ..............• Press and hold Tick to turn the display OFF ............• SETUP will be highlighted ....................•...
LCD Display Mesh Symbol - Displayed when connected to the neoHub. Day Indicator - Displays the day of the week. Holiday – Displayed when the time clock is in holiday mode. Set - Displayed when changes are being made to the current set point. Program Indicator - Displayed during programming to show which level is being altered.
Setting the Switching Times To program the switching times, follow these steps. • Use the Left / Right keys to scroll to EDIT and press Tick ......... • Use the Left / Right keys to select day/period of the week ......•...
Timer Override To override the timed output on, follow these steps. • Use the Up / Down keys to set the override duration e.g. 02:00 hours ..• Press Tick to confirm settings and return to main display ........Hold Left and the remaining time will now be displayed. HOLD LEFT Indicator Hold Time Remaining Series...
Optional Features Explained Feature 01 – Pairing To neoHub: This function is used to connect the time clock to the neoHub. Feature 02 - Weekday/Weekend (5/2), 7 Day Programming or 24 Hour Mode: The time clock offers three programming methods; Weekday/ Weekend (5/2) - Allows you to program 4 on/off switching times for the weekdays and 4 on/off switching times for the weekend.
Wiring Diagram - Time Clock Mode 230VAC RT2 RT1 A2 A1 VOLT FREE OUTPUT LIVE 230V SUPPLY IN NEUTRAL FOR 230V OUTPUT ON A2 LINK LIVE TO A1 This product must only be installed by a qualified electrician and comply with local installation regulations. Series...
Want More Information? Call our support team on: +44 (0)1254 669090 Or view technical specifications directly on our website: www.heatmiser.com Heatmiser UK Ltd Units 1-5 Hurstwood Court, Mercer Way Shadsworth Business Park, Blackburn, Lancashire, BB1 2QU, United Kingdom. Twitter: @heatmiseruk Facebook: facebook.com/thermostats...
Need help?
Do you have a question about the neoStat Series and is the answer not in the manual?
Questions and answers