Advertisement

Quick Links

Kalfire G and GP
User Manual
BALANCED-FLUE GAS FIRES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G60/48F and is the answer not in the manual?

Questions and answers

Summary of Contents for Kalfire G60/48F

  • Page 1 Kalfire G and GP User Manual BALANCED-FLUE GAS FIRES...
  • Page 3 Balanced-flue gas fires Kalfire G G60/48F, G65/44C, G70/44S G80/48F, G85/44C, G90/44S G100/41F, G105/37C, G110/37S G120/41F, G125/37C, G130/37S G160/41F, G165/37C, G170/37S For gas type: G20, G25, G30 en G31 Balanced-flue gas fires Kalfire GP GP60/59F, GP65/55C, GP70/55S GP60/79F, GP65/75C, GP70/75S GP75/59F, GP80/55C, GP85/55S...
  • Page 5 Register your fireplace for better service and support We recommend registering your fireplace. By registering, we have the correct information about your appliance. In case of a malfunction or maintenance, we can assist you faster and more efficiently – if your installer or dealer is unable to resolve the issue or is no longer reachable.
  • Page 7: Table Of Contents

    CONTENTS General information ................... 9 Foreword..........................9 Pictograms .......................... 10 Warranty ..........................11 Compatibility iMatch-interface .................. 12 Safety ........................13 Safety regulations for decorative elements ............13 Safety related to use ....................... 14 Three safety features of the gas fireplace ............. 16 Description ......................
  • Page 8 Declaration of conformity .................... 54 Declaration of conformity remote control ............56...
  • Page 9: General Information

    General information The following sections provide general information about the gas fire: Foreword  Pictograms  Warranty  iMatch interface compatibility  Foreword About this manual This manual is written for users of the gas fireplace. In addition to this user manual, a separate installation guide is available.
  • Page 10: Pictograms

    All rights reserved. No part of this manual may be copied, distributed or translated into other languages, in full or in part, without the prior written permission of Kalfire. Kalfire reserves the right to make changes to the manual. Kalfire, however, cannot provide any warranty, implicitly or explicitly, for this manual.
  • Page 11: Warranty

    Kalfire and the technical fitter approved by Kalfire. 12. A dated proof of purchase must be presented to Kalfire should a possible home repair service (only available in the Benelux, Germany, France and the United...
  • Page 12: Compatibility Imatch-Interface

    With regard to the huge diversity of appliances, their compatibility can regrettably not be confirmed beforehand. Only after installation of the interface can compatibility be confirmed. Kalfire accepts no liability for the non- functioning, or insufficient functioning, of the iMatch interface as a consequence of...
  • Page 13: Safety

    Safety The following sections provide safety information about the gas fire:: Safety regulations for decorative elements  Safety related to use  Three safety measures for the gas fire  Safety regulations for decorative elements DANGER! he decorative elements must be placed according to the instructions. It is prohibited to alter the number of decorative elements or the configuration thereof.
  • Page 14: Safety Related To Use

    Safety related to use There are risks attached to using a gas fire. The temperature of all visible parts of the gas fire can rise steeply and there is a risk of fire or combustion. Be sure that the following safety precautions have been taken:: WARNING! After installation, the visible parts of the gas fireplace (including the glass surface) are considered an active zone.
  • Page 15 Fig. 1: Safe zone Burn hazard DANGER! Do not touch the appliance! The gas fire is hot when switched on or just switched off. Ensure extra safety precautions and safety measures if less able-bodied persons, elderly people and/or children have access to the fireplace. Only the remote control and the technical unit can be used without fear of danger due to combustion.
  • Page 16: Three Safety Features Of The Gas Fireplace

    The risk of discoloration NOTICE! Dust particles, as well as particles from cigarette smoke, candles, and oil lamps, can cause discoloration of walls and ceilings when heated through the convection system of the gas fireplace. Ensure adequate ventilation in the room where the fireplace is installed.
  • Page 17 Kalfire gas fireplace installations meet enhanced airtightness requirements Kalfire closed gas fireplaces, together with the corresponding Kalfire air and flue systems, always meet airtightness requirements up to 50 Pa. This ensures that Kalfire gas fireplace installations comply with enhanced airtightness standards. As a result, building-specific conditions combined with other technical systems cannot lead to a dangerous amount of flue gases entering the installation space.
  • Page 18: Description

    Kalfire and cannot be added at a later stage. The Kalfire GP can also be delivered with an optional hybrid function. The gas fire’s fuel bed is equipped with LED lighting that simulates a bed of natural embers. The lighting generates an atmospheric imitation of the glow of a real wood fire.
  • Page 19 Smooth transition between gas fire and surround The balanced-flue gas fires are easy to align with the household interior during installation. The gas fire stone, often made from natural stone, can continue along the outer edge of the gas fire with the help of stone supports. The side walls can be fluidly finished in the surround of the gas fire.
  • Page 20: Operation

    4. Operation The upcoming sections provide information about the use of the gas fire: Replacing the batteries  Using the iMatch remote control  Setting the day and time  Confirming the transmission strength  Switching the gas fire on and off ...
  • Page 22: Replacing The Batteries

    Replacing the batteries Insert or replace the remote control AA batteries. A battery compartment is located at the rear of the remote control. This can hold two AA batteries. If the batteries are almost flat, the battery icon becomes visible or all symbols on the display start to flash.
  • Page 23: Setting Day And Time

    10. Time segments 11. Thermostat mode. 12. Manual program (default mode). Buttons: + and - buttons Button left and right Centre button On/off button Parameter configuration button P Setting day and time Follow the steps below to change the day and time settings: Hold down the P button until the time display starts flashing.
  • Page 24: Switching The Appliance On And Off

    Switching the appliance on and off Carry out the following steps to turn the appliance on or off: Press until the >OK< icon in the display appears and starts to flash. Continue to press and then press briefly on to activate the ignition program. Release both buttons.
  • Page 25: Setting The Flame Height By Thermostat

    after 24 hours. If the flames in the gas fire have been switched off, the program will restart in manual mode automatically when next switched on. By pressing P until the icon for thermostat or manual mode begin to flash. Press P again to select the icon of your choice.
  • Page 26: Program Choice For The Hybrid Led Lighting

    Set the desired temperature with the + or - buttons at increments of 0.5°C. Confirm by pressing the (center button). 10. Press the right button , so that a flashing time in hours and minutes appears in the top left-hand corner, while “ON 1” appears in the middle of the display (this is the first “on”...
  • Page 27: Activating/Deactivating The Hybrid Led Lighting And Adjusting The Lighting

    Press the right button until a “P1, P2 or P3” appears in the middle of the display. Press a number of times until the desired “P” program is displayed. Wait until the home screen appears. 4.11 Activating/deactivating the hybrid LED lighting and adjusting the lighting intensity If the gas fire is equipped with hybrid LED lighting, it will be automatically activated as soon as the fire is turned on.
  • Page 28: Installing The Imatch App

    Settings: SP0 = Natural Spark Generator is switched off; no sparks SP1= 1 spray of sparks per hour. SP2= 2 sprays of sparks per hour. SP3= 3 sprays of sparks per hour. SP4= 4 sprays of sparks per hour. SP5= 5 sprays of sparks per hour. SP6= 6 sprays of sparks per hour.
  • Page 29: How To Use The Imatch App

    4.15 How to use the iMatch App The gas fire can be controlled with the iMatch App, if the iMatch interface is connected to your local Wi-Fi network. First, install the iMatch App on your smartphone or tablet. Accessing home screen 1.
  • Page 30 Overview home screen Igniting flame: Press the standby icon. A half circle appears and the gas fire is  ignited. The flame intensity is 100%. Adjusting the flame intensity: Press and hold down the black dot. Move your  finger over the circle to set the flame intensity. The percentage will increase and decrease with the movement of your finger.
  • Page 31 Hybrid LED lighting: Press “off” to turn on the LED lighting. The LED lighting turns on and a semi-circle with the text Hybrid appears on the screen. The LED lighting intensity is not adjustable. NOTICE! The NSG cannot be operated by the iMatch.
  • Page 32 Heating mode: Tap “Manual” once in the middle of the circle. Now select the heating mode Eco or Manual. In case you choose Eco mode, the fireplace is not controllable from the app. The fireplace varies from mode 1 to 8 automatically.. Shutting down: The gas fire will shut down by pressing the standby button again.
  • Page 33: Maintenance

    (ceramic glass cleaner). Do not use corrosive or abrasive substances for cleaning the fireplace. Damage to enamel is not included in the warranty. Small damaged can be removed by using heat-resistant enamel. This enamel is available at Kalfire. 5.1.1 Cleaning the (standard)
  • Page 34 Use scratch-free cleaning substances only.  5.1.2 Cleaning instructions anti-reflective glass The gas fire glass can become dirty when the fireplace is burning, but also when being taken into use. Potential causes can be: Smoking materials in the fireplace (especially in the beginning), air contamination, quality of the type of gas etc. Anti-reflective glass is polished ceramic glass to which a number of metal oxide coatings have been applied that reduce the reflection to less than 1%.
  • Page 35: Door Dismantling And Assembly

    Never use the products below!:: The glass coating can be damaged by: toilet cleaners alkaline detergents or detergents with high levels hydrochloric acid of ammonia bleach domestos acids benzene, hexane or petroleum- chlorine or sodium hypochlorite based solvents detergents scouring powders, abrasive Aggressive cleaning materials materials, steel wool, scrubbing or scouring pads, scrapers, razor...
  • Page 36 Step 2: Push the metal cover strip in left or right. Step 3: Next, grip the door by the designated handles. Slightly lift the door with glass window out of the rabbet, move the entire door slightly to the left or right (corner fireplace) and carefully lift it entirely out of the fireplace.
  • Page 37 5.1.4 Door dismantling and assembly (front and tunnel fireplaces) Door removal WARNING! Wear (rubber) gloves to prevent stains on the glass. Step 1: Move the metal cover strips up from the upper side. : To unlock the door, pull the handles that are placed under the hood towards Step 2 you and up..
  • Page 38 5.1.5 Assembly and disassembly of the hearth extension and surround (Kalfire GP75/59F) If the fire has a decorative fireback (red brick / Flemish thin brick) with a decorative hearth extension and surround (jambs on either side of the glass screen), first remove the hearth extension, and then one of the vertical jambs.
  • Page 39: Malfunctions

    Disassembly of the hearth extension and surround WARNING! The hearth extension and surround are ceramic. Handle them with care as they are very fragile. Step 1: Slide the hearth extension (1) carefully outwards and place it to the side. Step 2: Slide one of the jambs (2) outwards until it is completely detached from the fire.
  • Page 40 fixed automatically when the remote control is placed closer to the technical unit of the fireplace. Press 1 x Signal malfunctions (indicated as >NOLK 0 or 1< or a flashing RF icon ). The remote control does not communicate with the fireplace. This malfunction cannot be fixed automatically.
  • Page 41 5.2.2 Error codes iMatch remote control Error code Cause Solution Entire display Flat battery Replace battery. flashing Battery is low Replace battery. NOLK 0 in Control error Briefly press >NOLK< will appear in the top left the middle of corner of the display. the display No communication Synchronising remote control:...
  • Page 42 11. Place the automatic burner relay back into the technical unit and close the hatch. Temperature of the Turn off the fireplace for approximately 30 circuit board is too minutes. high Then turn on the fireplace. In case the error reappears, there is insufficient ventilation in the chamber of the fireplace.
  • Page 43 Remove the door from the fireplace (see 5.1.3 and 5.1.4). Carefully check that no decorative elements are obstructing the pen and if the spark correctly ignites the burner. Ignite the gas fire without the door once and check if gas is emanating from the burner. In case no gas is emanating from the burner: check for gas supply up to the technical unit (measure pre-pressure).
  • Page 44: Error Code Imatch-Interface

    Change gas valve settings, parameter TP01 or TP02. Check/replace the gas valve. Low voltage gas valve Replace automatic burner relay Insufficient voltage Measure mains voltage (>220VAC) Measure outgoing transformer voltage 24 VDC and 12 VDC. If the outgoing voltage is lower than 20 VDC or 10 VDC, replace the transformer.
  • Page 45: Malfunctions Natural Spark Generator

    No power supply on the Natural Spark Generator check whether the Natural  Spark Generator has been connected correctly. See: paragraph 6.4. Natural Spark Generator pump / coil is defect -> contact your dealer or Kalfire.  Disammembly and disposal Disassemble the appliance at the end of its service life in accordance with local laws and regulations.
  • Page 46: Appendices

    Appendices TP01 and TP02: Installing Gas Valve Maximum burner pressure with parameter TP02 (default setting=70) Press and hold <P> (approximately 30 to 40 seconds) until “TCOM” appears and flashes on the screen. Release <P> and press and hold <P> again, then press <CB> shortly after: “FH01”...
  • Page 47 NOTICE! Take enough time to let the appliance burn at a certain flame intensity - the gas valve needs at least 30 seconds to generate the correct settings.
  • Page 48: Product Card - Part 1

    Product fiche – part 1 (in conformance with (EU) 2015/1186 Appendix IV)) Kalfire G Model G25.3 74,3 72,9 Kalfire G60/48F 85,3 80,0 74,8 Kalfire G65/44C G30 -30 mbar 75,3 68,3 78,7 Kalfire G70/44S G30 50 mbar 75,7 67,8 78,7 G25.3...
  • Page 49 Kalfire GP Model G25.3 76,1 62,7 82,6 Kalfire GP60/59F 76,0 66,7 98,0 Kalfire GP65/55C G30 -30 mbar 76,1 65,9 115,9 Kalfire GP70/55S G30 50 mbar 76,1 65,9 115,9 G25.3 76,3 66,2 104,5 Kalfire GP60/79F 76,2 67,4 103,7 Kalfire GP65/75C G30-30 mbar...
  • Page 50 Model G25.3 79,2 88,7 Kalfire GP110/59T Kalfire GP115/55R G30-30 mbar 82,0 G30 –50 mbar 82,0 G25.3 78,3 87,6 Kalfire GP110/79T Kalfire GP115/75R G30-30 mbar 76,3 G30 –50 mbar 76,5 Note 1: The values in these tables are inspection values in accordance with EN613.
  • Page 51: Product Fiche - Part 2

    Electricity consumption Kalfire G Consumption in Consumption at Consumption at standby mode minimum heat nominal heat (kWh) output (kWh) output (kWh) Fireplace turned 0,0033 Fireplace turned on 0,0087 0,0092 Note: The electricity consumption is the same for all Kalfire G models...
  • Page 52 0,0087 0,0092 Fireplace turned 0,0169 0,0173 -Hybrid/LED lighting Fireplace turned 0,0117 0,0121 - NSG function on Fireplace turned - NSG function on 0,0194 0,0199 - Hybrid/LED lighting on Note: The electricity consumption is the same for all Kalfire GP models...
  • Page 53: Wiring Diagram

    Wiring diagram Wiring diagram Natural Spark Generator in the technical unit...
  • Page 54: Declaration Of Conformity

    Kalfire GP80/54T, GP85/50R Kalfire GP105/59F, GP110/55C, GP115/55S, Kalfire GP105/79F, GP110/75C, GP115/75S Kalfire GP110/59T, GP115/55R Kalfire GP110/79T , GP115/75R Kalfire G60/48F, G65/44C, G70/44S, Kalfire G80/48F, G85/55C, G90/55S, Kalfire G100/41F, G105/37C, G11037S, Kalfire G120/41F, G125/37C, G130/37S Kalfire G160/41F, G165/37C, G170/37S This declaration of conformity is issued in accordance with the Union...
  • Page 55 Applied standards or other technical specifications to which this declaration relates: NEN-EN 613 (2022) NEN-EN 437 (2021) Notified body: Certigaz Rue du Général Leclerc CS-60264 92047 PARIS LA DEFENSE CEDEX France Date: 1-7-2025 Drs. Ing. Beijko van Melick Msc. General Manager Kalfire BV...
  • Page 56 Declaration of conformity remote control...
  • Page 60 Geloërveldweg 21 5951 DH Belfeld info@kalfire.com KALFIRE.COM...

Table of Contents