Summary of Contents for WhisperKool EXTREME Series
Page 1
EXTREME SERIES OWNER’S MANUAL Extreme 3500tiR Extreme 5000tiR Extreme 8000tiR Extreme 3500tiR FD Extreme 5000tiR FD Extreme 8000tiR FD The Coolest Thing In Wine Storage...
Page 2
WhisperKOOL. Every e ort has been made to ensure that the information in this manual is accurate. WhisperKOOL is not responsible for printing or clerical errors.
Customer Service Thank you for purchasing a WhisperKOOL Extreme Series cooling unit. We strive to provide the highest-quality products and the best possible customer service. If you have any questions about your WhisperKOOL unit, please call us at 1-800-343-9463 or visit www.whisperkool.com.
2. The unit should remain in an upright position for 24 hours prior to operation. 3. The WhisperKOOL unit requires a dedicated 115V, 20-amp circuit. Use a surge protector with the WhisperKOOL unit. Do not use a GFI (ground fault interrupter) line.
WhisperKOOL Customer Service immediately. Please leave the WhisperKOOL unit in its original box until you are ready for installation. This will allow you to move the product safely without damaging it. When you are ready to remove the product from the box, refer to the installation instructions.
Evaporator grille w/ lter Remote digital display Control panel (see page 13 for details) Bottle probe Fan speed control Rear / Side View Evaporator grille w/ lter UV power outlet UV/access panel Rear power inlet Drain port www.whisperkool.com | Page 5...
Page 8
Fully Ducted — Front / Side View Exhaust plenum Supply plenum Intake plenum Return plenum Rear Remote digital display Control panel (see page 13 for details) Drain port Bottle probe Fan speed control NOTE: Grilles and lters are not included with the fully ducted Extreme tiR. EXtiR 080924 Page 6...
Undersized cooling units can lead to premature failure and/or prevent the system from reaching the desired set temperature. As a result, they are not covered under warranty. www.whisperkool.com | Page 7...
Insulation Insulation is REQUIRED in order to properly use WhisperKOOL products. It is vital that all walls and ceilings be insulated to keep the cellar temperature as consistent as possible during the summer and winter months. Standard berglass or rigid foam insulation is normally used in cellar construction;...
Page 11
NOTE: Do not attempt mount the unit in a wall recess or attempt to camou age or cover the unit with any sort of aftermarket grille, accessory, etc. This can restrict air ow, prevent the unit from working properly, and void the warranty. Please feel free to call WhisperKOOL Customer Service with any questions or concerns regarding installation requirements. Door and Door Seal An exterior-grade (1¾”) door must be installed as a cellar door.
Page 12
In some cases, it may be advisable to install a vent fan to dissipate heat from within the exhaust area. However, you must have a fresh air inlet as well. If your unit requires ducting, please contact WhisperKOOL to obtain a specially designed ducting plenum for the unit.
PREPARING THE UNIT FOR INSTALLATION The WhisperKOOL unit requires a dedicated 115V, 20-amp circuit. The unit draws a large amount of amps during its initial startup. By designating a dedicated circuit breaker, you will guarantee the unit has enough power to run e ectively. Contact an electrician for assistance with the installation of this dedicated electrical circuit.
Make sure that the internal height remains at 16 inches (3500tiR & 5000tiR) or 22.75 inches (8000 tiR) so that the WhisperKOOL unit will t snugly through the framed cut-out. EXtiR 080924...
Page 15
5” inch thick wall (wall thickness may vary) Mounting Bracket Wine Cellar Exhaust Area #1 7.5–9.5” In Cellar #2 11.5–13.5” In Cellar #3 15.5–17.5” In Cellar #4 19.5–21.5” In Cellar www.whisperkool.com | Page 13...
OPTIONAL EXTERIOR GRILLE The exterior grille is required on all installations where the exhaust side of the unit is exposed to the outdoors (i.e., rain and other adverse weather conditions). Non-Flush Installation Install the unit according to the standard through-the-wall procedure. After the unit is installed, place the exterior grille over the exhaust side lter grille and align the screw holes on the sides of the unit.
The 1¾" screws should penetrate the studs as well as the upper and lower supports to provide ad- equate support for the WhisperKOOL unit (see illustration). Seal all cracks and gaps around the WhisperKOOL Extreme unit with an air-tight sealant or caulking to prevent air leakage.
DUCTING OVERVIEW Use ductwork to connect the unit to the supply and return outlets in the wine cellar. Use only insulated ductwork to minimize cooling losses, prevent sweating, and reduce noise. Use ductwork on the condenser section to redirect or absorb sound, bring in outside air to the unit inlet, and/or exhaust the hot air.
Half Duct Con guration Wine Cellar Air Supply (Cellar Side) Adjacent Room Return Air (Cellar Side) Three-Quarter Duct Con guration Condenser Exhaust Wine Cellar Air Supply (Cellar Side) Condenser Intake Adjacent Room Return Air (Cellar Side) www.whisperkool.com | Page 17...
Page 20
Fully Ducted Attic Mounted Unit It is recommended that you use a condensate pan for this application. Condenser Exhaust Cold Air Condenser Intake Return Air Fresh Air Intake EXtiR 080924 Page 18...
INSTALLING THE DUCT PLENUMS 1. Remove the lter grille from the unit by unscrewing the screws that hold it in place. 2. Move the ducting adapters into place. 3. Screw the ducting adapters into place using the supplied screws. www.whisperkool.com | Page 19...
CONDENSATION DRAIN LINE The condensation drain line tube is used to drain excess condensation from the unit to a proper discharge location. It is important that the drain line tube be properly connected in order to prevent leakage and other problems associated with excess condensation.
Extreme Series LIQUID MEASURING THERMOSTAT SYSTEM BOTTLE PROBE WhisperKOOL cooling units come with a liquid-temperature-measuring thermostat. The self-calibrating probe con- tains a sensor chip, which communicates back and forth with the thermostat. This results in a consistent temperature setting and accuracy. Wine should be kept at a very precise, controlled temperature and humidity. By measuring the liquid temperature rather than air, the unit will operate 75–80% of the time.
MULTI SPEED FAN CONTROL Designed for wine cellars up to 1000 and 2000 cubic feet, Extreme 3500tiR, 5000tiR, and 8000tiR units feature multi-speed fans. These fans have a high setting for maximum performance in high-temperature (+110°F) environments and a low setting for super-quiet operation.
1. Place the bracket on the wall. Use a level to ensure that the bracket is level. Using a pencil, mark the four screw holes in the rear of the bracket. NOTE: Cut hole in the location shown for routing the display cable. www.whisperkool.com | Page 23...
Page 26
WALL MOUNT BRACKET INSTALLATION, CONTINUED 2. Using a drill with a ⁄ ” bit, drill four holes in the drywall for the screws. Insert the four (4) provided drywall anchors into the drywall, then tap them in with a hammer until they are ush with the wall. 3.
Page 27
5. Place the display on the wall mount bracket as shown, attaching the back of the display panel to the magnets on the mounting bracket. Make sure that the alignment tab on the back of the display panel sits in the notch on the bottom of the bracket. www.whisperkool.com | Page 25...
Page 28
FLUSH MOUNT BRACKET INSTALLATION 1. Square the ush mount template on the wall 2. Peel the backing o the template and stick it to the wall, using a level. Then draw a 3” line along the aligning the bottom edge with the line drawn in Step 1. bottom edge of the template.
Page 29
5. Remove the backing from the double-sided tape on the ush mount bracket. 6. Align magnets with previously drilled holes. Make sure the cut-out portion of the bracket (circled below) is on the bottom. Press the bracket rmly against the wall. WALL HOLE CUTOUT www.whisperkool.com | Page 27...
Page 30
FLUSH MOUNT BRACKET INSTALLATION, CONTINUED 7. Connect the end of the display cable to the JST connector on the display panel. DISPLAY BRACKET 8. Place the display on the ush mount bracket as shown, attaching the back of the display panel to the magnets on the mounting bracket.
SYSTEM OPERATION Initial Start-Up Safety Features When the unit is plugged in and power is sent to the In the event of a faulty bottle probe, the compressor will cycle controller, a beep will sound, con rming that the control- o for 10 minutes and on for 40 minutes.
Fan is on Anti-Frost Cycle running °F Scroll Button Return to Previous Menu Change Setpoint View/Change Setpoint Scroll Button Enter User Menu Change Setpoint (hold for 3 sec) Unlock Button Power On/O (hold for 1 sec) www.whisperkool.com | Page 31...
CONTROLLER FUNCTIONS Button Normal Functions When the unit is plugged in and power is sent to the controller, a beep will sound, con rming INITIAL STARTUP that the controller is getting power. All LEDs on the display will blink three times. Three dashes will then appear on the screen.
The alarm icon is shown when the unit encounters an issue that needs attention. Alarm codes ALARM are explained on the following page. All temperature-related alarms are blocked for the rst 10 hours after the unit is plugged in to allow the system to stabilize and acclimate to the new environment. www.whisperkool.com | Page 33...
Page 36
WHISPERKOOL CONTROLLER ALARM CODES Code Cause Solution The following alarm codes will be displayed on the screen along with the alarm icon. Bottle probe is not connected Attach bottle probe to circular connector Faulty bottle probe connection Locate faulty bottle probe connection by inspecting all wiring connections between the bottle probe and the circuit board.
Page 37
2. 2 = activates the compressor and fans 5 = disables the compressor and fans NOTE: Setting the dOA to any number other than 2 or 5 will prevent the unit from operating properly. www.whisperkool.com | Page 35...
If so, call Customer Service at 1-800-343-9463. System runs constantly Possible cause Solution Leaky door seal or poorly insulated cellar Fix leaky door seal and insulate cellar in accordance with this manual (page 9) www.whisperkool.com | Page 37...
Page 40
Unit leaks water Possible cause Solution Unit is level °) System should have a two-degree (2 pitch towards the exhaust side Drain line clogged or kinked Check drain line to make sure water can ow freely Drain is clogged, preventing water from escaping 1.
They are harmful or fatal if ingested. Wear protective gloves when handling pan tabs. Wash hands thoroughly after handling. If pan tabs make contact with eyes, rinse cautiously with water for several minutes. In case of an emergency, call 1-800-255-3924 (24 hours). www.whisperkool.com | Page 39...
FILTER REPLACEMENT PROCEDURE NOTE: For 3500/5000 models the lters will be located at the return register inside the wine cellar. Replace lters according to speci c register type selected by customer. EXtiR 080924 Page 40...
TECHNICAL ASSISTANCE WhisperKOOL Customer Service is available Monday through Friday from 6:00 a.m. to 4:00 p.m. Paci c Standard Time. The appointed customer service representative will be able to assist you with your questions and warranty information more e ectively if you provide them with the following: The model and serial number of your WhisperKOOL system(s).
Page 44
A. Two (2) Year Limited Warranty. For the period of TWO (2) YEARS (the “Limited Warranty Period”) from the date of original sale of a Product by WhisperKOOL and up to an additional (6) month grace period, if a WhisperKOOL Self- Contained Product is found to be defective in material or work-manship after undergoing WhisperKOOL’s customer...
Page 45
16. No one has any authority to add to or vary the limited warranty on this Product. 3. Product Installation Requirements: A. Prior to installing a WhisperKOOL Product, the End User must read the WhisperKOOL Owner’s Manual and there- after the End User must follow the required installation, use and maintenance procedures set forth by Whis- perKOOL in WhisperKOOL’s Owner’s Manual.
Page 46
D. End User is responsible for all costs incurred for the installation and/or removal of the Product, or any part there- of, unless such cost has been agreed by WhisperKOOL to be a warranty repair prior to the work being performed.
Page 47
Web: www.whisperkool.com B. Technical Assistance. WhisperKOOL Customer Service is available Monday through Friday from 6:30 a.m. to 4:00 p.m. PST. The Customer Service representative will be able to assist you with your questions and warranty infor- 1. The model and serial number of your WhisperKOOL UNIT.
Page 48
Your credit card will be pre-authorized for the total deposit and charged when the replacement order is shipped and invoiced. If you fail to return the original WhisperKOOL unit or part to the factory within 30 days, or no problem is found ...
Page 49
WhisperKOOL 1738 E. Alpine Ave Stockton, CA 95205 www.whisperkool.com...
Need help?
Do you have a question about the EXTREME Series and is the answer not in the manual?
Questions and answers