5000ti EXTREME OWNER’S MANUAL For: 5000ti 5000tir The Coolest Thing In Wine Storage...
Page 2
WhisperKOOL. Every effort has been made to ensure that the information in this manual is accurate. WhisperKOOL is not responsible for printing or clerical errors.
WHISPERKOOL Series QUICK REFERENCE GUIDE Bottle Probe Controller Probe Input Front Grille Rear Power Option Page 4 Front / Side View Speed Control Rear View Control Panel (see page 15 for details) Posterior Grille Drain Port PT-EXPL5000 060311...
QUICK CONTROLLER REFERENCE GUIDE Standard Controller Layout - XR70CX If your unit is installed through the wall and does not have a remote keypad you will have the Xr70CX Controller Note: The 1 or 3-5 qualifies the amount of time in seconds that the button must be pushed to activate the feature.
Your fan speed selection will depend on the amount of heat that needs to be removed from the cellar, as well as the application of the unit (Thru the Wall Installation or Ducted). If the unit is going to be ducted you would need to use the highest fan speed (The higher fan speed is designed to support the reduction in airflow created by the ductwork) For the thru the wall application, the fan speed selection will depend on the cellar size, insula- tion factor, door seal and desired wine temperature.
Thank you for purchasing a WhisperKOOL Extreme Series cooling unit. We strive to provide the highest quality prod- ucts and the best possible customer service. If you have any questions about your WhisperKOOL unit, please call us at 1(800) 343-9463.
Connection “T” (1) Please leave the WhisperKOOL unit in its original box until you are ready for installation. This will allow you to move the product safely without damaging it. When you are ready to remove the product from the box, refer to page 15 for installation instructions.
WhisperKOOL unit. Do not use a GFI (Ground Fault Interrupter) line. 4. For your convenience, the Whisperkool unit has two power inlets, one on the side of the unit and the other on the back. Use the selector switch, located on the right side of the unit, to select the inlet you would like to use.
PREPARING THE WINE CELLAR The performance and life of your WhisperKOOL unit are contingent upon the steps you take in preparing the wine cellar. Note: Improperly preparing your enclosure or incorrectly installing your WhisperKOOL unit may cause unit fail- ure, leaking of condensation, and other negative side effects.
As the room cools down, the warm air will rise to the ceiling. Mounting the WhisperKOOL high in the room will create a consistently cool environment by capturing the warm air and replacing it with cool air.
Page 12
However, you must have a fresh air inlet as well. If your unit requires ducting, please contact WhisperKOOL Customer Service to obtain a specially designed ducting accessory kit for the unit. Using any other ducting system will void the warranty.
5000ti/tiR 1000 med 5000ti/tiR 1000 low Cutting the Hole for the WhisperKOOL Unit Tools Needed Hammer Locate the desired installation location. Using a stud finder, locate the studs on either side of the center point, and mark them with vertical lines.
Page 14
Sheetrock alone cannot support the weight of a 96-pound (or more) cooling system. Therefore, it is necessary to frame the hole that you have just cut with upper and lower supports. Using two 2x4s at 14.5” in length and eight 6d nails, secure the upper and lower supports to the right and left studs, just inside the sheetrock.
Plug your WhisperKOOL unit into a surge protector or power conditioner. As with any sensitive electrical equip- ment, the WhisperKOOL electrical equipment may be damaged by power surges and spikes. Power surges and spikes are not covered in the WhisperKOOL Extreme warranty.
This foam creates a tight seal between the flange and the wall. Page 16 #2. Retrofit your current WhisperKOOL cooling unit Back of unit Front of unit PT-EXPL5000 060311...
The screws should penetrate the studs as well as the upper and lower supports to provide adequate support for the WhisperKOOL system (see illustration). Seal all cracks and gaps around the WhisperKOOL Extreme unit with an air-tight sealant or caulking to prevent air leakage.
Page 18
Condensation Drain Line Tube The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location. It is important that the drain line tube is properly connected and used to prevent leakage and other problems associated with excess condensation.
• For a non-flush installation (i.e. holes location #2 WhisperKOOL retrofit or #1 Middle Wall or #3), place the grille on the condenser end and line up the holes on the grille with the holes on unit location #4. Use the 8 self tapping screws provided to fasten the grille to the unit.
LIQUID MEASURING THERMOSTAT SYSTEM The WhisperKOOL Series cooling units come equipped with a liquid temperature measuring thermostat system. This system incorporates the following advantages: 1. Self-Calibrating Probe: The probe contains a sensor chip, which actually communicates back and forth to the thermostat. This results in a consistent temperature setting and accuracy. Do not remove the tip from the probe! 2.
REMOTE CONTROLLER: INSTALLATION AND CONFIGURATION The WhisperKOOL Extreme Series can be configured with a remote controller system. If you have a unit with a remote controller, please review this section. The controller can be installed up to 50 feet away from the cooling unit, or up to 300 feet away with the extend- ed connection wire.
Page 22
Connection wire in Side Mount configuration Connection wire in Rear Mount configuration Below is an illustration of one possible way to configure the remote controller in a wine cellar. Cooling Unit Bottle Probe Remote Controller Page 22 PT-EXPL5000 060311...
MULTI SPEED CONTROL Designed for wine cellars from up to 1000 cubic feet, the Extreme 5000ti features multi-speed fans with a “high” setting for maximum performance in high-temperature (+110°F) environments and a “low” setting for super- quiet operation. Fan Speed Selector Switch (Low/Med/High): The cooling unit fans operate on 3 speed settings: Low, Medium, and High.
Standard and Remote Controllers Initial Start-Up When power is applied to the unit, the control will briefly display all symbols, and the Compressor sym- bol will be displayed (if unit is calling for cooling). There may be a brief delay prior to the evaporator and condenser fans turning on, as the fans will not turn on until the sensors reach their perspective start tempera- tures (below 120°F for the evaporator and condenser).
STANDARD CONTROLLER FUNCTIONS - XR70CX If your unit is installed through the wall and does not have a remote keypad you will have the Xr70CX Controller. Button • ON/OFF The ON/OFF button allows the customer the convenience of turning the refrigera- tion system ON or OFF, from the control panel.
Page 26
Energy Reduction 1. The ER feature can be used to save energy and aids in extending the life of the sys- (ER) tem. 2. The ER button is located at the top L/H side of the control. The ER feature is acti- vated by pressing the ER button one time, and the ER logo will appear on the digital display.
CPSM CCS – Cellar Pre-Chill Set Point: This parameter is set at 52°f, but can be adjusted to a set point Mode between 50°f - 67°f. (Cont.) CCT - Cellar Pre-Chill Duration: This parameter is set to 6 hours, but can be changed between 0-23.5 hours.
REMOTE CONTROLLER FUNCTIONS - XW260K If your unit has a remote keypad then you will have the XW260K controller. Display Set Point Button • ON/OFF The ON/OFF button allows the customer the convenience of turning the refrigera- tion system ON or OFF, from the control panel. This feature does not disconnect power from the unit.
Page 30
1. Press the “Set” button once and it will display the Set Point. After approximately 5 Button seconds, the display will return to normal operation and display the Bottle Probe temperature. 2. Press the “Set” button once and it will display the Set Point. Press the up and down arrows to change the set point.
Page 31
CPSM CCT - Cellar Pre-Chill Duration: This parameter is set to 6 hours, but can be changed between Mode 0-23.5 hours. (Cont.) Con/Cof – Compressor On time (Con) and Off time (Cof ) with a Probe 1 failure/Alarm. These parameters are set at Con 40 min/Cof 10 min. In the event that there is a Probe 1 failure/Alarm, the compressor/refrigeration system automatically starts a predetermined ON/OFF cycle, which is controlled by the Con and the Cof parameters.
MAINTENANCE SCHEDULE Monthly 1. Check filters 2. Check for unusual noise or vibration 3. Check the drainline to see if it is above the waterline if draining into a vessel. Quarterly Clean filters: Remove grille/ducting on both ends of unit. 2.
Unit has ice forming on the evaporator Possible Cause Evaporator filter and/or coil are dirty. There is something blocking the supply and or return air The evaporator fan is not turning on. The temperature of the room, the unit is exhausting to, has dropped below 45°...
Page 35
TROUBLESHOOTING GUIDE Unit leaks water Possible Cause Unit is not level Drain line clogged or kinked Drain is clogged preventing water form escaping Drain line does not have a downward slope Coil is iced causing drain pan ice and water overflowing Unit runs but does not cool Possible Cause Lack of air flow...
WhisperKOOL Customer Service is available Monday through Friday from 8:00 a.m. to 4:00 p.m. Pacific Time. The customer service representative will be able to assist you with your questions and warranty information more effectively if you provide them with the following: •...
Conditions is English. WhisperKOOL reserves the right, in its sole discretion, to change these Terms and Conditions at any time, for any reason, without notice. WhisperKOOL shall not be liable to Purchaser for any delay of delivery of a Product caused by Force Majeure, or any other cause beyond WhisperKOOL’s control.
Page 38
(5) Proof of purchase of the Product in the form of a bill of sale or receipted invoice, which is evidence that the Product is within the Limited Warranty Period, must be presented by the End User to WhisperKOOL in order to obtain limited warranty service.
Page 39
Terms and Conditions, except that these Terms and Conditions shall be interpreted as through drafted jointly by WhisperKOOL and Purchaser. Any dispute will be resolved by the courts in the County of San Joaquin, State of California, and all parties, WhisperKOOL, Purchaser and End User, hereby irrevocably submit to the personal jurisdiction of such courts for that purpose.