Mastervolt CP 100TR Installation Manual
Mastervolt CP 100TR Installation Manual

Mastervolt CP 100TR Installation Manual

Central power grid connected solar inverter
Hide thumbs Also See for CP 100TR:

Advertisement

Quick Links

CENTRAL POWER GRID CONNECTED SOLAR INVERTER
MASTERVOLT
Snijdersbergweg 93,
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
Fax.: +31-20-6971006
www.mastervolt.com
INSTALLATION MANUAL
CP 100TR
ENGLISH:
NEDERLANDS:
DEUTSCH:
FRANÇAIS:
CASTELLANO:
ITALIANO:
PAGE 1
PAGINA 25
SEITE 49
PAGINA 73
PÁGINA 97
PÁGINA 121
v 1.1 June 2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP 100TR and is the answer not in the manual?

Questions and answers

Summary of Contents for Mastervolt CP 100TR

  • Page 1 INSTALLATION MANUAL CP 100TR CENTRAL POWER GRID CONNECTED SOLAR INVERTER ENGLISH: PAGE 1 MASTERVOLT NEDERLANDS: PAGINA 25 Snijdersbergweg 93, DEUTSCH: SEITE 49 1105 AN Amsterdam FRANÇAIS: PAGINA 73 The Netherlands CASTELLANO: PÁGINA 97 Tel.: +31-20-3422100 ITALIANO: PÁGINA 121 Fax.: +31-20-6971006 www.mastervolt.com...
  • Page 2 Main AC grid cover connection Neutral (N) terminal for Motor driven DC AC power supply disconnector [Q1] Protective Earth (PE) terminal (2x) Figure 1: Inside view of the CP100 inverter Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 3: Table Of Contents

    Auxiliary terminals ............................18 5.7.1 X1: External power supply....................... 18 5.7.2 X2: Alarm and control contacts......................18 Communication cables ............................. 19 Final steps ................................ 19 SPECIFICATIONS ................................. 20 ORDERING INFORMATION............................23 EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 4: General Information

    Among other things, this means that all Never remove the identification label(s). instructions and warnings given in this manual are taken into account during installation, that commissioning is Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 5: Safety Guidelines And Warnings

    The DC voltage of the purpose. Mastervolt is not liable for any damage resulting DC link must be less than 10 Volt DC from the above. EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 6 The inverter must not operate in an unsafe condition. Make sure that you made all necessary checks before running the system. Make sure that all cable connections are tightened with the correct torque. Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 7: How It Works

    Refer to the operation manual for more details about the the AC circuit breaker and contactors. Islanding protection operation of the CP100 inverter Figure 3: principle schematics of the CP100 inverter EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 8: Before You Start

    The CP100 inverter must be stored in its original packaging. The storage location must be dry to prevent humidity entering the cabinet on the long term. Figure 4: Use of a forklift Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 9: Installation Environment

    4C1 (outdoor) and 3C1L (indoor) Mechanical active classification is 4S2 (outdoor) and 3S2 (indoor). • Relative humidity: 10% up to 95%. • Ambient temperature: 0 ... 50°C. Figure 6 EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 10: Unpacking

    Depending on local applicable regulations the installation of additional protection devices and/or approval by the electric utility company may be compulsory. Acquaint yourself with the local regulations on the above mentioned issues. Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 11: Installation

    CP inverter. Refer wrenches helpful during to standard VDE 0100 part 7-712 and VDI 6012 installation of the CP inverter regulations for additional information. EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 12: Opening The Cabinet

    Move the Main AC circuit breaker Q2 to the “OFF” or Figure 10: Use of the spring-cage terminals “0” position • Use the supplied key to release the door lock Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 13: Pv Array Connections

    PV strings must be of DC breakers identical length. In such case each PV array must be (5x) protected by fuses. Figure 11: Connection to DC circuit breakers EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 14: Standard Connection

    DC busbar DC busbar plastic protection cover retention rail with retention rail with cable clamps cable clamps Figure 12: Standard connection of the DC wiring to the DC-bus bars Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 15: Connection To Dc Circuit Breakers

    Availability of string connections 3, 4 and 5 is optional STRING 1 STRING 2 STRING 3 STRING 4 STRING 5 Figure 13: Connection of the DC wiring to the DC circuit breakers EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 16: Main Ac Grid And Protective Earth Connection

    Route the cable from below the cabinet through the cable inlet area of the cabinet to the circuit breaker. Fix the lower insulating terminal cover on the circuit breaker (Figure 14) Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 17: Ac Power Supply Connection

    Neutral (N) terminal bypass wires between terminals X1.1 - X1.3 and X1.2 – X1.5 terminals X1.1, X1.2, X1.3, X1.4 and X1.5 Figure 17: AC power supply connection EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 18: Auxiliary Terminals

    Emergency feedback: X2.6 and X2.7 X2.7 X2.8 X2.17 X2.18 Insulation monitor feedback: X2.18, X2.19 and X2.20 X2.19 X2.20 Figure 18: Wiring of the alarm and control contacts X2. Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 19: Communication Cables

    Mastervolt authorized service agent.. CAUTION! Refer to the operation manual for commissioning of All cable entries and sliding plates must be CP-inverter. completely sealed to prevent the entry of small animals. EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 20: Specifications

    250A MPP tracker MPP efficiency > 99,9% DC connection Tubular cable lugs for M8 bolts (Standard connection) or cable end sleeves, max 70mm² (Connection to DC circuit breakers) Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 21: Safety Features

    Type approval TÜV EMC directive 89/336/EWG + 93/31/EWG Emissions EN61000-6-4 Grid quality requirements VDEW compliant Immunity EN61000-6-2 LV directive 73/23/EWG Electrical safety EN50178 National grid interface req. VDEW compliant EN / Installation CP100 / June 2009 / Copyright © 2009 Mastervolt...
  • Page 22 SPECIFICATIONS Figure 21: Outline drawings of the CP100TR inverter. All dimensions are in mm See www.mastervolt.com for free download of AutoCAD drawings. Copyright © 2009 Mastervolt / June 2009 / Installation CP100 / EN...
  • Page 23: Ordering Information

    See section 4.3 for an overview of parts that are standard included with the delivery of the CP100 inverter Mastervolt offers a wide range of products for both grid connected and independent autonomous electrical installations. See our website www.mastervolt.com for an extensive overview of all our products...
  • Page 24 Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel : + 31-20-3422100 Fax : + 31-20-6971006 Email : info@mastervolt.com...

This manual is also suitable for:

131400100

Table of Contents