OPERATION MANUAL
CP inverter
ENGLISH:
NEDERLANDS:
DEUTSCH:
FRANÇAIS:
CASTELLANO:
ITALIANO:
PAGE 1
PAGINA 25
SEITE 49
PAGINA 73
PÁGINA 97
PÁGINA 121
v 1.0 June 2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP100TR and is the answer not in the manual?

Questions and answers

Summary of Contents for Mastervolt CP100TR

  • Page 1 OPERATION MANUAL CP inverter CP100TR, CP200TR, CP200TL & CP140TR-LV CENTRAL POWER GRID CONNECTED SOLAR INVERTER ENGLISH: PAGE 1 MASTERVOLT NEDERLANDS: PAGINA 25 Snijdersbergweg 93, DEUTSCH: SEITE 49 1105 AN Amsterdam FRANÇAIS: PAGINA 73 The Netherlands CASTELLANO: PÁGINA 97 Tel.: +31-20-3422100 ITALIANO: PÁGINA 121...
  • Page 2: Table Of Contents

    TROUBLE SHOOTING ..............................15 General ................................15 Restart of the CP inverter ..........................15 De-commissioning............................16 Explanation of the error codes.......................... 17 Error codes listing............................. 18 SPECIFICATIONS ................................. 22 Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 3: General Information

    Never remove the identification label(s). operation. Among other things, this means that all instructions and warnings given in this manual are taken EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 4: Safety Guidelines And Warnings

    DC link must be less than 60 Volts DC. 2.2 is not considered to be consistent with the intended purpose. Mastervolt is not liable for any damage if the above qualifications are not met. Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 5 The inverter must not operate in an unsafe condition. Make sure that you made all necessary checks before running the system. Make sure that all cable connections are tightened with the correct torque. EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 6: How It Works

    T4. From 230VAC source. this transformer, the AC power passes the EMC filter and Figure 2: principle schematics of the CP inverter Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 7: Operation Modes

    P_PV < P_SG_Min Failure Shutdown mode U_PV = Voltage of the PV modules P_PV = Power of the PV modules Figure 3: Operation modes of the CP inverter EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 8: Stand-By Mode

    DC voltage was found during this scan, the continuous tracker will start again from this point. Refer to the APPENDIX for more details and configuration possibilities of the MPPT Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 9: Operation

    Position and availability may differ, depending on the commissioning, service and maintenance of model. the CP inverter, the Safety Guidelines & Measures are applicable at all times. See chapter 2 of this manual. EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 10: Emergency Button

    This screen is only shown during start-up of the inverter, for instance after first commissioning of after sunrise. It will disappear when the inverter is operating normally Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 11: Status Check

    See also section 6.1. Touch the “Return to Main menu” section to return to the Main menu EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 12: Configuration

    These settings can only be changed by means of an Ethernet connection; see installation manual. Touch the “Return to Main menu” section to return to the Main menu Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 13: Setting Date And Time

    “Save” section, followed by touching the “Exit” section to reboot the display Figure 17 Then touch the “Offline” section at the bottom of the display (Figure 17) EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 14: Commissioning After Installation

    Short circuiting, miswiring or reverse polarity (“Shutdown” mode) and will switch back to the of a single DC input may damage the inverter “Standby” mode and may result in fire. Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 15: Trouble Shooting

    In most cases such errors will be solved instantly when the AC grid parameters are within range again. Then the inverter will switch on automatically. EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 16: Commissioning

    CP100 inverter are voltage free. Disconnect both DC and AC wiring. Now the CP100 inverter can be demounted in a safe way. Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 17: Explanation Of The Error Codes

    EXPLANATION OF THE ERROR CODES The table below gives an overview of possible errors that can be shown on the display of the CP inverter. Consult a Mastervolt authorized service agent for support if you cannot solve the problem by means of this table.
  • Page 18: Error Codes Listing

    Phase current L3 > 400A Overcurrent Phase L3, Software Grid current L3 > 180A Overcurrent I_DC, HW-controlcard IDC too high Overcurrent I_DC, Software IDC > 280A Unsymmetry Inverter currents n.a. Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 19 Grid voltage L3 > 110% x U nominal Overvoltage DC Link, HW control card DC input voltage > 900 V Overvoltage DCLink, Software DC input voltage > 900 V EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 20 Undervoltage grid Phase L3, stage 4 Undervoltage grid Phase L3, stage 5 Grid voltage L3 < 90% x U nominal Undervoltage DC Link, HW control card Undervoltage DC Link, Software Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 21 Check the grid frequency Software Errors Wrong Systemparamter No error Errorcounter overrun (x errors / hour) User switched off Inverter via Display or Ethernet See section xx EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 22: Specifications

    MPP tracker MPP efficiency > 99,9% DC connection Tubular cable lugs for M8 bolts (Standard connection) or cable end sleeves, max 70mm² (Connection to DC circuit breakers) Copyright © 2009 Mastervolt / June 2009 / Operation CP inverter / EN...
  • Page 23: Safety Features

    TÜV EMC directive 89/336/EWG + 93/31/EWG Emissions EN61000-6-4 Grid quality requirements VDEW compliant Immunity EN61000-6-2 LV directive 73/23/EWG Electrical safety EN50178 National grid interface req. VDEW compliant EN / Operation CP inverter / June 2009 / Copyright © 2009 Mastervolt...
  • Page 24 Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel : + 31-20-3422100 Fax : + 31-20-6971006 Email : info@mastervolt.com...