  • Page 1 PANTHER 56-72-90 Manuale di Installazione uso e manutenzione Installaltion, use and maintenance manual BULLETIN M0042 E ITEN _ 00...
  • Page 2: Machine And Manufacturer Identification

    - Machinery Regulations - Electromagnetic compatibility The technical file is at the disposal of the competent authority following motivated request at PIUSI S.p.A. or following request sent to the e-mail address: doc_tec@ piusi.com. THE ORIGINAL DECLARATION OF CONFORMITY IS PROVIDED SEPARATELY...
  • Page 3: Safety Instructions

    ENGLISH (Translated from Italian) This manual belongs to Piusi S.p.A., which is the sole proprietor of all rights indicated by applicable laws, including, by way of example, laws on copyrights. All the rights deriving from such laws are reserved to Piusi S.p.A.: the reproduction, including partial, of this manual, its publication,...
  • Page 4: Technical Data

    10.3 DUTY CYCLE NOTE The electrical pumps Panther 56 and Panther 72 are designed for continuous use under conditions of maximum back pressure. The electrical pump Panther 90 is designed for alternating use with duty cycle 30” ON and 30” OFF.
  • Page 5 ENGLISH (Translated from Italian) 11.1 POSITIONING, CONFIGURATIONS AND ACCESSORIES NOTE In the case of installation in the open air, proceed to protect the pump by providing a protection roof. The pump can be installed in any position (pump axis vertical or horizontal) The pump must be secured in a stable way using the holes on the bed of the motor and vibration damping devices.
  • Page 6: Piping Connections

    ENGLISH (Translated from Italian) SINGLE-PHASE Single-phase motors are supplied with a pre-existing MOTORS 2 - meter cable with electric plug. To change the cable, open the terminal strip cover and connect the line according to the following diagram. Single-phase motors are supplied with a bi-polar switch and capacitor wired and installed inside the terminal strip box (see diagram).
  • Page 7: 17 Problems And Solutions

    Resume operations as described in Paragraph L - DAILY USE, after determining the cause of the stoppage. MAINTENANCE Safety Panther 56, Panther 72 and Panther 90 pumps are designed and instructions constructed to require a minimum of maintenance. Before carrying out any maintenance work, disconnect the dispensing system from any electrical and hydraulic power source.