Page 4
The person authorised to compile the technical file and draw up the declaration is Otto Varini as legal representative. Suzzara 29/12/2009 the legal representative ! Warning: The CUBE MC dispensing units described in this manual are for professional use only.
This manual refers to CUBE MC models only. SAFETY INSTRUCTIONS All the CUBE MC models have been designed and built according to applicable EC directives relating to essential safety and health requirements. Page 4 of this manual shows a copy of the manufacturer's DECLARATION OF CONFORMITY.
Fully open the packaging and take out the CUBE MC so that it can be taken to the place of final installation. Due to the weight of Cube MC, the product should be removed from its packaging by 2 persons.
USING AND LOOKING AFTER MANUALS This manual is common to all CUBE MC models and illustrates the main characteristics of the various models, providing information on: - electrical and mechanical installation...
(Translated from Italian) LIST OF SUPPLIED MANUALS Below is a list of all the manuals, besides this one, to be provided together with the CUBE MC: - M0042 Panther 72 pump manual - M0147 K600/3 die-cast meter manual - M0103 CUBE MC control system manual...
For further details, see the manual indicated on the summary table of paragraph E1. NOZZLE The nozzle supplied with CUBE MC is of automatic type; it is fitted with a shut-off device for full tank. DISPLAY UNIT COVER To ensure adequate protection and the correct visibility of the CUBE MC display units, including in very strong light conditions, a pull-out display unit cover has been integrated in the structure.
• Liquids with viscosity > 20 cSt (motor overload). ABSORBED POWER The CUBE MC stations must be powered by a power line with the same RATED VOLTAGE / FREQUENCY as that indicated on the IDENTIFICATION PLATE. The maximum acceptable variations from the electrical parameters are:...
INSTALLATION GENERAL CUBE MC can be installed outside. Nevertheless, it is advisable to locate it under the shelter of a roof to ensure the dispenser's longevity and provide greater comfort during refuelling in the event of bad weather. The installation of the dispenser must be carried out by skilled personnel and performed according to the instructions provided in this chapter.
Maximum acceptable electrical parameter variations are ±5%. ! ATTENTION The CUBE MC dispenser does not feature overload cutouts and, consequently, a switchboard must be fitted upstream of the CUBE MC complete with residual current circuit breaker suitable for the type of CUBE MC to be installed.
Page 13
(Translated from Italian) CUBE MC features a terminal board cover. Inside this cover are the terminals which the installer must connect up to: - The mains power line - The RS 485 data line to the PC (optional). The connector block, accessible through the front panel opening, is already wired up to the CUBE MC components, according to the block diagram shown below.
Page 14
(Translated from Italian) Below are the main connections and the fuses to be replaced by skilled service technicians only.
MC control system functions must be known (see attached manual). ELECTRICAL POWER SUPPLY Once the power connections have been made, the CUBE MC can be energised by means of the master switch to be fitted by the installer on the upstream line. Switching on of the MC system will be indicated by the lighting up of the two backlit LCDs fitted on the front.
• Reach the graduated area of the sample container, avoiding prolonged dispensing at low flow rate, but rather performing short dispensing operations at maximum flow rate. • Compare the reading provided by the container, with that provided by CUBE MC, after waiting for all the froth to disappear.
(Translated from Italian) DAILY USE Thanks to the MC control system, all the CUBE MC models provide access to authorised users only. MC acknowledges User authorisation by means of two alternative systems: - The entering of a 4-figure SECRET CODE (PIN CODE).
Remember that the nozzle can be opened only when the spout is in the tank. ROUTINE MAINTENANCE CUBE MC has been designed so as to require minimum maintenance. For utmost station efficiency and safety, the following inspection and ROUTINE maintenance operations should however be regularly performed.
The MC system is maintenance free. To control it however, refer to the dedicated M0103 manual provided. FILTERS CUBE MC features a number of filters having different functions. The inspection and cleaning (or replacement) of each filter is crucial to ensure: - The protection of the various station components (pulser, pump, nozzle).
Should the need arise however and/or in case of special maintenance, it can be cleaned as described in the PULSER MANUAL, after removing the roof of CUBE MC (if necessary) by means of its relevant upper screws (see exploded view, pos.14).
Check that the voltage is not more START WITH Electric voltage too low than 5% below the nominal voltage NOZZLE CLOSED Lower the CUBE MC with respect Excessive suction pressure to the tank or increase the diameter of the tubing Use shorter tubing or of greater...
SPECIAL MAINTENANCE In order to change the fuses inside the electronic board panel, we suggest proceeding as follows: - Interrupt power to the CUBE MC - Remove the cover of the MC BOX panel - Replace the burnt out fuses...
EDITION: Bullettin M0104D EN - Rev. 1 PRODUCT: Diesel fuel dispenser for private use with meter MODEL: All the models of the CUBE MC range, with single-phase/three-phase mechanical/electronic meter, with various voltages/frequencies CONFORMITY: CE MARK (see Declaration of conformity, page 4)
Page 28
330 South Maple Street | Corona, Ca. USA PH: 951-531-8870 | FAX: 951-531-8827 www.fueltransfer.com Authorized reseller's stamp M0104D EN - Rev.1...