Dräger X-plore 3300 Instructions For Use Manual
Hide thumbs Also See for X-plore 3300:

Advertisement

Atemfilter
de
Dräger X-plore
Respiratory filter
en
Dräger X-plore
Filtre respiratoire
fr
Dräger X-plore
Filtro respiratorio
es
Dräger X-plore
de cierre de bayoneta
Filtri di protezione respiratoria
it
Dräger X-plore
con attacco a baionetta
Ademfilter
nl
Dräger X-plore
0158
TP TC 019/2011
®
Bajonett
®
Bayonet
®
baïonnette
®
®
®
bajonet
Gebrauchsanweisung
Instructions for Use
Notice d'utilisation
Instrucciones de uso
Istruzioni per I'uso
Gebruiksaanwijzing
Australian
Standard
AS/NZS 1716:2012
Lic No 1346
SAI Global

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X-plore 3300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dräger X-plore 3300

  • Page 1 Atemfilter Gebrauchsanweisung ® Dräger X-plore Bajonett Respiratory filter Instructions for Use ® Dräger X-plore Bayonet Filtre respiratoire Notice d'utilisation ® Dräger X-plore baïonnette Filtro respiratorio Instrucciones de uso ® Dräger X-plore de cierre de bayoneta Filtri di protezione respiratoria Istruzioni per I'uso ®...
  • Page 2 X-plore 3300/3500 X-plore 5500...
  • Page 3: Intended Use

    EN - Instructions for Use For your safety Strictly follow the Instructions for Use. Any use of the respiratory filter requires the full understanding and strict observation of these Instruc- tions for Use and the Instructions for Use of the used facepiece (X- ®...
  • Page 4 6738776 ABEK2HgP3 R D 6738819 Legend: can be used with X-plore 3300/3500, X-plore 3350/3550 half mask or X-plore 5500 full face mask may only be used with X-plore 5500 full face mask Criteria for the selection of filter apparatus sets...
  • Page 5: Service Life

    Table 4: Particle filter Type Col- Catego- Filter effi- Limitations ciency code White Small Not against carcinogenic and radioactive materials, airborne biological substances of risk category 2 and 3 and enzymes Medium Not against radioactive materi- als, airborne biological sub- stances of risk category 3 and enzymes High...
  • Page 6: Notified Body

    Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck Germany Tel. +49 451 8 82 - 0 Fax +49 451 8 82 - 20 80 www.draeger.com Notified body Involved in type approval Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (IFA) Alte Heerstraße 111 53757 Sankt Augustin Germany...

This manual is also suitable for:

X-plore 3500X-plore 3350X-plore 3550

Table of Contents