The Power Assign Dialog; Using Power Assign: 1) Clear Channels - AMX TPDESIGN4 V2.5 Instruction Manual

Touch panel design program
Table of Contents

Advertisement

The Power Assign dialog

Select Button > Power Assign (or press F8) to open the Power Assign dialog, where you can set
button-level actions, channel/variable text, and code parameters one or more selected buttons. The
options in this dialog include:
Function Code Action
• Clear:
• Assign:
Function Code Type
• Channel:
• Address:
• Level:
Function Code Assignment Options
• Begin Assignment At: Sets the button group's starting device and channel numbers (if you select the Func-
• Port:
• Function Code:
• Ensure Contiguous
Code Assignment:
• Reuse Previously
Assigned Codes:
Code Assignments
• Split Across Port IDs: Sets the program to create a different device number for each channel. For example,
• Wrap Within Port ID:

Using Power Assign: 1) Clear Channels

One powerful feature of Power Assign is the ability to clear the various function codes from the
buttons. Since the buttons remain selected after the paste operation, all you need to do is bring up
the Power Assign dialog, then:
1. Under Function Code Action, select Clear.
2. Under Function Code Type, select Channel, Address or Level.
3. Click Assign.
TPDesign4 Touch Panel Design Program
Clears the button group's channel or variable text setting based on the option you
select in the What to change area. Choose Channel to clear the channel numbers or
Variable Text to clear the variable text in the button group.
Sets the button group's channel or variable text assignments based on the option you
select in the What to change area. Choose Channel to set the channel numbers or
Variable Text to set the variable text in the button group.
Sets the button group's channel numbers (if you select the Function Code Action/
Assign option).
Sets the button group's address numbers (if you select the Function Code Action/
Assign option).
Sets the button group's level numbers (if you select the Function Code Action/Assign
option).
tion Code Action/Assign option).
Sets the button group's port numbers (if you select the Function Code Action/Assign
option).
Sets the button group's function codes (if you select the Function Code Action/Assign
option).
Sets the button group's device and channel number assignments to be contiguous
(i.e. 1, 2, 3, etc).
Sets the codes, starting at either port 1/channel 1 or what you specify in the Start At
field without regard to previously utilized codes.
port 1/channel 255, and port 2/channel 1 are considered to be split across device
IDs.
Sets the program to avoid creating two or more channels with different device num-
bers.
Working With Buttons