Download Print this page
Supermicro SuperServer SYS-212B-FLN2T User Manual
Supermicro SuperServer SYS-212B-FLN2T User Manual

Supermicro SuperServer SYS-212B-FLN2T User Manual

Advertisement

Quick Links

SuperServer
®
SYS-212B-FLN2T
USER'S MANUAL
Revision 1.0 (MNL-2842)

Advertisement

loading
Need help?

Need help?

Do you have a question about the SuperServer SYS-212B-FLN2T and is the answer not in the manual?

Questions and answers

Summary of Contents for Supermicro SuperServer SYS-212B-FLN2T

  • Page 1 SuperServer ® SYS-212B-FLN2T USER'S MANUAL Revision 1.0 (MNL-2842)
  • Page 2 The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.
  • Page 3: About This Manual

    Technical Support email addresses can be found at: "Contacting Supermicro" on page 13 If you have any feedback on Supermicro product manuals, contact our writing team at: Techwriterteam@supermicro.com This manual may be periodically updated without notice. Check the Supermicro website for...
  • Page 4: Conventions Used In The Manual

    SuperServer SYS-212B-FLN2T: Preface Conventions Used in the Manual Special attention should be given to the following symbols for proper installation and to prevent damage done to the components or injury to yourself. Warning! Indicates important information given to prevent equipment/property damage or personal injury.
  • Page 5: Table Of Contents

    SuperServer SYS-212B-FLN2T: Contents Contents Contacting Supermicro Chapter 1: Introduction 1.1 Overview 1.2 System Features Front View Drive Carrier LED Indicators NVMe SSD LED Indicators Control Panel Rear View 1.3 System Architecture Main Components System Block Diagram 1.4 Motherboard Quick Reference...
  • Page 6 SuperServer SYS-212B-FLN2T: Contents Releasing the Inner Rail Installing the Inner Rails onto the Chassis Installing the Outer Rails onto the Rack 2.3 Installing the Chassis into the Rack Removing the Chassis from the Rack Chapter 3: Maintenance and Component Installation 3.1 Removing Power...
  • Page 7 SuperServer SYS-212B-FLN2T: Contents Battery Installation 3.7 Storage Drives Removing Hard Drive Carriers from the Chassis Installing a Storage Drive into a Drive Carrier Hot-Swap for NVMe Drives Ejecting a Drive Replacing a Drive 3.8 System Cooling Fans Changing a Fan...
  • Page 8 SuperServer SYS-212B-FLN2T: Contents Standby Power SATA 3.0 Ports TPM/Port 80 Header USB Header VROC RAID Key Header Control Panel Power Button Reset Button Power Fail LED Overheat/Fan Fail and UID LED NIC1/NIC2 (LAN1/LAN2) HDD LED Power LED NMI Button I/O Ports...
  • Page 9 SuperServer SYS-212B-FLN2T: Contents 5.3 BMC BMC ADMIN User Password Chapter 6: Optional Components 6.1 TPM Security Module 6.2 HBA Card 6.3 RAID Cards 6.4 Cable Management Arm Installing the Cable Management Arm Removing the Cable Management Arm 6.5 Intel Virtual RAID on CPU (VROC)
  • Page 10 SuperServer SYS-212B-FLN2T: Contents 7.4 CMOS Clear 7.5 Motherboard Battery 7.6 Where to Get Replacement Components 7.7 Technical Support Procedures Returning Merchandise for Service 7.8 Feedback Chapter 8: UEFI BIOS 8.1 Introduction Updating BIOS Starting the Setup Utility 8.2 Main Setup 8.3 Advanced Setup Configurations...
  • Page 11 Network Stack Configuration Menu MAC:(MAC address)-IPv4 Network Configuration Menu MAC:(MAC address)-IPv6 Network Configuration Menu PCIe/PCI/PnP Configuration Menu HTTP Boot Configuration Menu Supermicro KMS Server Configuration Menu Super-Guardians Configuration Menu System Diagnostics Configuration Menu Intel(R) Ethernet Controller Menu TLS Authenticate Configuration Menu...
  • Page 12 SuperServer SYS-212B-FLN2T: Contents Comply with Local and National Electrical Codes Product Disposal Fan Warning Power Cable and AC Adapter Appendix C: System Specifications Appendix D: General Data Center Environmental Specifications...
  • Page 13: Contacting Supermicro

    SuperServer SYS-212B-FLN2T: Contacting Supermicro Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: Marketing@supermicro.com (General Information) Sales-USA@supermicro.com (Sales Inquiries) Government_Sales-USA@supermicro.com (Gov. Sales Inquiries) Support@supermicro.com (Technical Support) RMA@Supermicro.com...
  • Page 14: Chapter 1: Introduction

    SuperServer SYS-212B-FLN2T: Introduction Chapter 1: Introduction This chapter provides a brief outline of the functions and features of the SYS-212B-FLN2T system. It is based on the X14SBI-TF motherboard and the 223M2-R000LPNP chassis. 1.1 Overview 1.2 System Features Front View Rear View 1.3 System Architecture...
  • Page 15: Overview

    One 2000W Redundant Titanium Level (96%) power supply Form Factor 2U Rackmount Notes: A Quick Reference Guide can be found on the following page of the Supermicro website: https://www.supermicro.com/en/products/system/iot/2u/sys-212b-fln2t The following safety models associated with the SYS-212B-FLN2T have been certified as compliant with UL or CSA: 223M-R20X14 223M-20, CSV-223M-R000RCNDP, MBD-X14SBM-TF-P, PWS-2K09F-1R.
  • Page 16: System Features

    SuperServer SYS-212B-FLN2T: Introduction 1.2 System Features The following views of the system display the main features. Refer to the System Specifications appendix of this manual for additional specifications. Front View The following features are located on the front of the SYS-212B-FLN2T server.
  • Page 17: Nvme Ssd Led Indicators

    SuperServer SYS-212B-FLN2T: Introduction Drive Carrier LED Indicators Color Pattern Device Behavior Blue Solid Idle SAS/NVMe drive installed Activity LED Blue Blinking I/O activity Idle SATA or no drive Solid Failure of drive with RSTe support Blinking at 1 Hz Rebuild drive with RSTe support...
  • Page 18: Control Panel

    SuperServer SYS-212B-FLN2T: Introduction Control Panel The following switches and LEDs are located on the SYS-212B-FLN2T server control panel. Figure 1-2. SYS-212B-FLN2T Control Panel Control Panel Features Feature Description Applies or removes primary power from the power supplies to the server but Power Button maintains standby power.
  • Page 19: Rear View

    SuperServer SYS-212B-FLN2T: Introduction Information LED Color, Status Description UID has been activated locally to locate the server in Blue, solid a rack environment. UID has been activated via BMC to locate the server Blue, blinking at 1 Hz in a rack environment.
  • Page 20: System Architecture

    SuperServer SYS-212B-FLN2T: Introduction 1.3 System Architecture This section covers the locations of the system's main components and provides a system block diagram. Main Components Figure 1-4. SYS-212B-FLN2T Main Component Locations System Features: Top Feature Description DIMM Slots Eight DIMMs supporting up to 2TB 6400MT/s ECC DDR5 RDIMM Single Socket E2 (LGA-4710) Intel®...
  • Page 21: System Block Diagram

    SuperServer SYS-212B-FLN2T: Introduction System Features: Top Feature Description Default* Three PCIe 5.0 x16 (in x16) HHFL slots Three PCIe 5.0 x8 (in x8) HHFL slots Option A* Three PCIe 5.0 x16 (in x16) HHFL slots Three PCIe 5.0 x8 (in x8) HHFL slots One PCIe 5.0 x16 (in x16) FHFL double-width slot...
  • Page 22: Motherboard Quick Reference

    SuperServer SYS-212B-FLN2T: Introduction 1.4 Motherboard Quick Reference For details on the X14SBI-TF motherboard layout and other quick reference information, refer to the content below. Motherboard Layout Figure 1-6. and Motherboard Layout...
  • Page 23: Quick Reference Table

    SuperServer SYS-212B-FLN2T: Introduction Notes: For detailed information on jumpers, connectors, and LED indicators, see "Maintenance and Component Installation" on page "■" indicates the location of pin 1. Components not documented are for internal testing purposes only. Use only the correct type of onboard CMOS battery as specified by the manufacturer.
  • Page 24 SuperServer SYS-212B-FLN2T: Introduction Connector Description Front Control Panel Header JIPMB1 System Management Bus Header (for IPMI only) Chassis Intrusion Header JM2_1, JM2_2 M.2 M-Key PCIe 5.0 x2 Connectors (supports 22110 form factor) JNCSI1 NC-SI Port Selection JNVI²C1 Non-volatile Memory (NVMe) I²C Header MCIO PCIe 5.0 x8 Connectors (JNVME1 and JNVME2 support CXL 2.0 devices.
  • Page 25 SuperServer SYS-212B-FLN2T: Introduction Connector Description USB0/1 USB 3.2 Gen 1 Ports USB2/3 USB 3.2 Gen 1 Header VGA Port Note: Jumpers, connectors, switches, and LED indicators that are not described in these tables are for manufacturing testing purposes only, and are not covered in this manual.
  • Page 26: Chapter 2: Server Installation

    SuperServer SYS-212B-FLN2T: Server Installation Chapter 2: Server Installation This chapter provides advice and instructions for mounting your server in a server rack. If your server is not already fully integrated with processors, system memory, etc., refer to "Maintenance and Component Installation" on page 39 for details on installing those specific components.
  • Page 27: Unpacking The System

    SuperServer SYS-212B-FLN2T: Server Installation 2.1 Unpacking the System Inspect the box the server was shipped in and note if it was damaged in any way. If any equipment appears damaged, file a damage claim with the carrier who delivered it.
  • Page 28: Preparing For Setup

    SuperServer SYS-212B-FLN2T: Server Installation 2.2 Preparing for Setup The box in which the SYS-212B-FLN2T server was shipped should include the rackmount hardware needed to install it into the rack. Read this section in its entirety before you begin the installation.
  • Page 29: Rack Mounting Considerations

    SuperServer SYS-212B-FLN2T: Server Installation Use a regulating uninterruptible power supply (UPS) to protect the server from power surges and voltage spikes and to keep your system operating in case of a power failure. Allow any drives and power supply modules to cool before touching them.
  • Page 30: Ambient Operating Temperature

    SuperServer SYS-212B-FLN2T: Server Installation Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the room's ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (TMRA).
  • Page 31: Locking Tabs

    SuperServer SYS-212B-FLN2T: Server Installation Locking Tabs The inner rails have a locking tab. These tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
  • Page 32: Releasing The Inner Rail

    SuperServer SYS-212B-FLN2T: Server Installation Figure 2-3. Extending the Long Outer Rail 4. Insert the inner rail in the longer outer rail, then secure it by pressing the locking tab on the back side as shown below. Figure 2-4. Identifying the Locking Tab on the Inner Rail 5.
  • Page 33: Installing The Inner Rails Onto The Chassis

    SuperServer SYS-212B-FLN2T: Server Installation Figure 2-5. Extending and Releasing the Inner Rail Installing the Inner Rails onto the Chassis The inner rails can be installed onto the SYS-212B-FLN2T server without any tools. Important: Do not pick up the server with the front handles. They are designed to pull the system from a rack only.
  • Page 34: Installing The Outer Rails Onto The Rack

    SuperServer SYS-212B-FLN2T: Server Installation 4. Optionally, you can further secure the inner rail to the chassis with a screw. 5. Repeat for the other inner rail. Figure 2-6. Installing the Inner Rails Installing the Outer Rails onto the Rack Each end of the assembled outer rail includes a bracket with hooks and square, spring-loaded pegs to fit into the square holes in your rack.
  • Page 35 SuperServer SYS-212B-FLN2T: Server Installation 3. Hang the hooks of the rear section of the outer rail onto the square holes on the rear of the rack. Take care that the proper holes are used so the rails are level. If desired, use screws to secure the rear of the outer rail to the rear of the rack.
  • Page 36: Installing The Chassis Into The Rack

    SuperServer SYS-212B-FLN2T: Server Installation 2.3 Installing the Chassis into the Rack After the rails are installed on the SYS-212B-FLN2T server and on the rack, the server can be installed in the rack. Important: Use caution when mounting or removing the system from the rack. For large systems, at least one other person must assist during installation or removal.
  • Page 37: Removing The Chassis From The Rack

    SuperServer SYS-212B-FLN2T: Server Installation Figure 2-9. Fastening the SYS-212B-FLN2T into the Rack Removing the Chassis from the Rack Important: Use caution when mounting or removing the system from the rack. For large systems, at least one other person must assist during installation or removal. Follow the safety recommendations printed on the rails.
  • Page 38 SuperServer SYS-212B-FLN2T: Server Installation Figure 2-10. Removing the SYS-212B-FLN2T from the Rack...
  • Page 39: Chapter 3: Maintenance And Component Installation

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Chapter 3: Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components for the SYS-212B-FLN2T server. To prevent compatibility issues, only use components that match the specifications and/or part numbers given.
  • Page 40 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Battery Removal Proper Battery Disposal Battery Installation 3.7 Storage Drives Removing Hard Drive Carriers from the Chassis Installing a Storage Drive into a Drive Carrier Hot-Swap for NVMe Drives 3.8 System Cooling Fans Air Shrouds 3.9 Expansion Cards...
  • Page 41: Removing Power

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 3.1 Removing Power Before performing some setup or maintenance tasks, use the following procedure to ensure that power has been removed from one or more nodes of the SYS-212B-FLN2T server. Removing Power from a Node Use the operating system to power down the node.
  • Page 42: Accessing The System

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 3.2 Accessing the System The SYS-212B-FLN2T server features a removable top cover, which allows easy access to the inside of the server. Removing the Chassis Cover Important: Except for short periods of time, do not operate the server without the cover in place.
  • Page 43: Static-Sensitive Devices

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 3.3 Static-Sensitive Devices Electrostatic Discharge (ESD) can damage electronic components. To avoid damaging your motherboard, it is important to handle it very carefully. The following measures are generally sufficient to protect your equipment from ESD.
  • Page 44: Processor And Heatsink Installation

    (gold contacts). Improper installation or socket misalignment can cause serious damage to the processor or processor socket. When buying a processor separately, use only a Supermicro certified heatsink. Refer to the Supermicro website for the most recent processor support.
  • Page 45: Overview Of The Processor Carrier

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Note: The motherboard supports three processor SKUs: SP XCC, SP HCC, and SP LCC. Each SKU supports a specific carrier; the SP XCC processor supports Carrier E2A while SP HCC and SP LCC support Carrier E2B. Make sure the processors of the same SKU are on the motherboard.
  • Page 46: Overview Of The Processor Socket

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-5. Carrier Bottom View (SP XCC E2A left, SP HCC/LCC E2B right) Overview of the Processor Socket The processor socket is protected by a plastic protective cover. Figure 3-6. Plastic Protective Cover and Processor Socket...
  • Page 47 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-7. Heatsink (1U) Figure 3-8. Heatsink (2U)
  • Page 48 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-9. Heatsink (4U) Figure 3-10. Carrier (SP XCC E2A left, SP HCC/LCC E2B right) Figure 3-11. Processor (SP XCC E2A left, SP HCC/LCC E2B right)
  • Page 49: Installing The Processor

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Installing the Processor To install the processor, follow the steps below: 1. Before installation, make sure the lever on the processor carrier is pressed down as shown below. Figure 3-12. Carrier Lever (SP XCC left, SP HCC/LCC right) 2.
  • Page 50 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-14. Carrier (SP XCC E2A left, SP HCC/LCC E2B right) 3. Use the triangles as a guide to carefully align and place one end of the processor into the latch marked A, and place the other end of the processor into the latch marked B as shown below.
  • Page 51: Assembling The Processor Heatsink Module

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-17. SP HCC/LCC E2B Keys and Latches Together Figure 3-18. Carrier Assembly Completed (SP XCC E2A left, SP HCC/LCC E2B right) Assembling the Processor Heatsink Module After installing the processor into the carrier, mount it onto the heatsink to create the processor...
  • Page 52 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 1. Loosen the Torx screw from the heatsink. Figure 3-19. Loosening the Screw 2. Gently pull the heatsink fan upward to detach it from the heatsink.
  • Page 53 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-20. Heatsink Fan Detached 3. Note the label on top of the heatsink, which marks the airflow direction. Turn the heatsink over and orient the heatsink so the airflow arrow is pointing towards the triangle on the processor.
  • Page 54 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-21. Carrier with 1U Heatsink (SP XCC left, SP HCC/LCC right) Figure 3-22. Carrier with 2U Heatsink (SP XCC left, SP HCC/LCC right)
  • Page 55 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-23. Carrier with 4U Heatsink (SP XCC left, SP HCC/LCC right) Figure 3-24. PHM Plastic Clips Locked(1U)
  • Page 56 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-25. PHM Plastic Clips Locked (2U) Figure 3-26. PHM Plastic Clips Locked (4U) 6. Examine all corners to ensure that the plastic clips on the processor carrier are firmly attached to the heatsink.
  • Page 57 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-27. 1U PHM Completed (SP XCC left, SP HCC/LCC right) Figure 3-28. 2U PHM Completed (SP XCC left, SP HCC/LCC right)
  • Page 58: Preparing The Processor Socket For Installation

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-29. 4U PHM Completed (SP XCC left, SP HCC/LCC right) Preparing the Processor Socket for Installation This motherboard comes with a plastic protective cover installed on the processor socket. Remove it from the socket to install the Processor Heatsink Module (PHM). Gently pull up one corner of the plastic protective cover to remove it.
  • Page 59: Preparing To Install The Phm Into The Processor Socket

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-31. Plastic Protective Cover Removed Preparing to Install the PHM into the Processor Socket After assembling the Processor Heatsink Module (PHM), you are ready to install it into the processor socket. To ensure the proper installation, follow the procedures below: 1.
  • Page 60 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 2. Locate four PEEK nuts (marked A, B, C, and D) and four rotating wires (marked 1, 2, 3, and 4) on the heatsink. Figure 3-33. PEEK Nuts and Rotating Wires (1U) Figure 3-34. PEEK Nuts and Rotating Wires (2U)
  • Page 61 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-35. PEEK Nuts and Rotating Wires (4U) 3. Check the rotating wires (marked 1, 2, 3, and 4) to make sure that they are at unlatched positions before installing the PHM into the processor socket.
  • Page 62: Installing The Processor Heatsink Module

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-38. 4U Unlatched Positions Installing the Processor Heatsink Module 1. Align pin 1 of the PHM with the printed triangle on the processor socket. 2. Make sure all four PEEK nuts of the heatsink (marked A, B, C, and D) are aligned with the threaded fasteners (marked a, b, c, and d), then gently place the heatsink on top of the processor socket.
  • Page 63 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-40. Aligning the Heatsink with the Socket (2U) Figure 3-41. Aligning the Heatsink with the Socket (4U) 3. Press all four rotating wires outwards and make sure that the heatsink is securely latched into the processor socket.
  • Page 64 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-42. Latching the PHM (1U) Figure 3-43. Latching the PHM (2U)
  • Page 65 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-44. Latching the PHM (4U) 4. With a T30 bit torque driver set to a force of 8.0 in-lbf (0.904 N-m), gradually tighten the four screws to ensure even pressure. You can start with any screw, but make sure to tighten the screws in a diagonal pattern.
  • Page 66 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-45. Installing the PHM with a Torque Driver (1U) Figure 3-46. Installing the PHM with a Torque Driver (2U)
  • Page 67 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-47. Installing the PHM with a Torque Driver (4U) 6. Align the aluminum fan shroud against the top of the 4U heatsink. The fan shroud was designed to match perfectly with the top of the heatsink in terms of geometric shape.
  • Page 68 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-48. Aligning the Heatsink Fan 7. When the fan shroud and the top of the heatsink are properly aligned, gently push the fan onto the heatsink until the bottom of the fan properly rests on the two hooks of the...
  • Page 69 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-49. Installing the Heatsink Fan 8. Insert the Torx screw into the screw hole on top of the heatsink and turn it clockwise to tighten the screw. Figure 3-50. Tightening the Screw...
  • Page 70: Removing The Processor Heatsink Module

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 9. Connect the fan power connector to a 4-pin fan header on the motherboard. Figure 3-51. Connecting the Fan Power Removing the Processor Heatsink Module Before removing the processor heatsink module (PHM) from the motherboard, shut down the system and then unplug the AC power cord from all power supplies.
  • Page 71 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-52. Loosening the Screw and Unplugging the Fan Power Header 2. Gently pull the heatsink fan upward to detach it from the heatsink.
  • Page 72 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-53. Removing the Fan 3. Use a screwdriver to loosen the four screws. You can start with any screw, but make sure to loosen the screws in a diagonal pattern.
  • Page 73 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-54. Loosening the Screws (1U) Figure 3-55. Loosening the Screws (2U)
  • Page 74 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-56. Loosening the Screws (4U) 4. Press the four rotating wires inwards to unlatch the PHM from the socket. Figure 3-57. Unlatching the PHM (1U)
  • Page 75 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-58. Unlatching the PHM (2U) Figure 3-59. Unlatching the PHM (4U) 5. Gently lift the PHM upwards to remove it from the socket.
  • Page 76 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-60. Removing the PHM from the Socket (1U) Figure 3-61. Removing the PHM from the Socket (2U)
  • Page 77 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-62. Removing the PHM from the Socket (4U) 6. To remove the processor from the heatsink, gently lift the lever from the processor carrier. Figure 3-63. Carrier with 1U Heatsink (SP XCC left, SP HCC/LCC right)
  • Page 78 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-64. Carrier with 2U Heatsink (SP XCC left, SP HCC/LCC right) Figure 3-65. Carrier with 4U Heatsink (SP XCC left, SP HCC/LCC right) 7. To remove the processor, move the lever to its unlocked position and gently remove the...
  • Page 79 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-66. Removing the Processor (SP XCC left, SP HCC/LCC right)
  • Page 80: Memory Support And Installation

    3.5 Memory Support and Installation Important: To prevent any damage, exercise extreme care when installing or removing memory modules. Note: Check the Supermicro website for recommended memory modules. Memory Support The X14SBI-TF motherboard supports up to 2TB 6400MT/s ECC DDR5 RDIMM in 8 DIMMs memory slots.
  • Page 81 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation ® ® CXL Memory Configuration Support for Intel Xeon 6700/6500-Series Processors with P- Cores Native DDR5 Memory Per Socket CXL Memory Per Socket Slot 0 Slot 0 DRAM Capacity 4S and DIMM DIMM DIMM...
  • Page 82 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Notes: The items with an asterisk (*) are the default settings in the BIOS. ® ® The Intel Xeon 6700/6500-series processors with P-cores CXL memory configurations are 1DPC ('Slot 0') only for native DDR5.
  • Page 83 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation ® ® DDR5-6400 Memory Support for Intel Xeon 6700-Series Processors with E-Cores (Only DDR5-6400 Related RDIMMs Supported) DIMM Capacity (GB) Speed (MT/s); Voltage (V); Slots per Channel (SPC) and DIMMs per Channel DRAM Density...
  • Page 84: General Guidelines For Optimizing Memory Performance

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Notes: The items with an asterisk (*) are the default settings in the BIOS. ® ® The Intel Xeon 6700-series processors with E-cores CXL memory configurations are 1DPC ('Slot 0') only for native DDR5.
  • Page 85: Dimm Installation

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation DIMM Installation Important: To avoid causing any damage to the memory module or the DIMM socket, do not use excessive force when pressing the release tabs on the ends of the DIMM socket. Handle memory modules with care.
  • Page 86 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 4. Align the notches on both ends of the module against the receptive points on the ends of the slot. Figure 3-69. Aligning the Notches 5. Press both ends of the module straight down into the slot until the module snaps into place.
  • Page 87: Dimm Removal

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation DIMM Removal Important: To avoid causing any damage to the memory module or the DIMM socket, do not use excessive force when pressing the release tabs on the ends of the DIMM socket. Handle memory modules with care.
  • Page 88: Motherboard Battery Removal And Installation

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 3.6 Motherboard Battery Removal and Installation Battery Removal To remove the onboard battery, follow the steps below: 1. Power off your system and unplug your power cable. 2. Locate the onboard battery as shown below.
  • Page 89: Storage Drives

    These carriers also help promote proper airflow. Figure 3-73. Storage Drives Note: Enterprise-level storage modules are recommended for use in Supermicro servers. Removing Hard Drive Carriers from the Chassis 1. Press the release button on the drive carrier, which will extend the driver carrier handle, then use the drive carrier handle to pull the drive out of the chassis.
  • Page 90: Hot-Swap For Nvme Drives

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-74. Installing a Storage Drive Hot-Swap for NVMe Drives Supermicro servers support NVMe surprise hot-swap. For even better data security, NVMe orderly hot-swap is recommended. NVMe drives can be ejected and replaced remotely using BMC.
  • Page 91: Replacing A Drive

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-75. BMC Screenshot Replacing a Drive 1. Insert the replacement drive. 2. BMC > System > Storage Monitor > Physical View 3. Select Device, Group, and slot and click Insert. The drive Status LED indicator flashes...
  • Page 92: System Cooling

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 3.8 System Cooling Refer to the following sections for information about the cooling capabilities of the SYS-212B- FLN2T server. Fans Four 8038 fans with fan cages are supported by the SYS-212B-FLN2T server. Changing a Fan 1.
  • Page 93 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 3. Gently push the air shroud into place. Figure 3-77. Installing an Air Shroud...
  • Page 94: Expansion Cards

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 3.9 Expansion Cards Refer to the following sections for information on the expansion cards supported by the SYS- 212B-FLN2T server. PCIe Cards The system supports for installing expansion cards. Riser cards position the expansion cards at a 90 degree angle, allowing them to fit inside the chassis.
  • Page 95 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 3. Remove the bracket from the chassis using the two square holes located at the top of the bracket, if present. 4. Install the PCIe expansion cards into the riser card. 5. Install the assembly into the chassis and connect any additional wires.
  • Page 96: Cable Routing Diagrams

    SuperServer SYS-212B-FLN2T: Maintenance and Component Installation 3.10 Cable Routing Diagrams The below diagram indicates the cable routing for IO cables. When disconnecting cables to add or replace components, refer to the diagram so you can reroute them in the same manner. If cables are not connected or routed properly it may lead to device detection or performance issues.
  • Page 97: Power Supply

    In the event of a power module failure, the other power module will continue to power the system on its own. Failed power supply modules can be replaced without powering down the system. Replacement modules can be ordered directly from Supermicro. Information LED...
  • Page 98 SuperServer SYS-212B-FLN2T: Maintenance and Component Installation Figure 3-81. Replacing the Power Supply...
  • Page 99: Chapter 4: Motherboard Connections, Jumpers, And Leds

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs Chapter 4: Motherboard Connections, Jumpers, and LEDs This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here.
  • Page 100: Headers And Connections

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs ATX Power 24-pin Connection 8-pin CPU Power Pin Definitions: 24 Total Pin Definitions: Eight Total Pin# Definition Pin# Definition Pin# Definition +3.3 V +3.3 V 1–4 No Connection +3.3 V +12 V (12 V 5–8...
  • Page 101: Com Header

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs COM Header There is one COM header JCOM1 on the X14SBI-TF motherboard. Use a cable to connect the COM header, which provides communication support. (missing or bad snippet) COM Header Pin Definitions: Nine Total...
  • Page 102: Fan Headers

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs Fan Headers There are seven 4- pin fan headers (FAN1– FAN5, FANA, FANB) on the X14SBI- TF motherboard. All the 4-pin fan headers are backwards compatible with the traditional 3-pin fans. However, fan speed control is available for 4-pin fans only by Thermal Management via the IPMI 2.0 interface.
  • Page 103: Mcio Pcie 5.0 X8 Connectors

    An NVMe SMBus (I²C) header is located at JNVI²C1 on the X14SBI-TF motherboard. It is used for PCIe SMBus clock and data connections, provides hot-plug support through a dedicated SMBus interface. This feature is only available for a Supermicro complete system with a Supermicro proprietary NVMe add-on card and a proper cable installed.
  • Page 104: Power Smb (I²C) Header

    The JTPM1 header on the X14SBI-TF motherboard is used to connect a Trusted Platform Module (TPM)/Port 80, which is available from Supermicro (optional). A TPM/Port 80 connector is a security device that supports encryption and authentication in hard drives. It allows the...
  • Page 105: Usb Header

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs motherboard to deny access if the TPM associated with the hard drive is not installed in the system. following link more information TPM: https://www.supermicro.com/manuals/other/AOM-TPM-9670V_9670H__X12_H12.pdf. For a detailed diagram of the X14SBI-TF motherboard, see the layout under "Motherboard...
  • Page 106: Vroc Raid Key Header

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs VROC RAID Key Header A VROC RAID Key header is located at JRK1 on the X14SBI-TF motherboard. Install a VROC RAID key on JRK1 for NVMe RAID support as shown in the illustration below.
  • Page 107: Control Panel

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs Control Panel Refer to the following content for information about the front control panel header on the X14SBI-TF motherboard. Power Button The Power Button connection is located on pins 1 and 2 of JF1 on the X14SBI-TF motherboard.
  • Page 108: Overheat/Fan Fail And Uid Led

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs Power Fail LED Pin Definitions (JF1) Pin# Definition +3.3 V PWR Supply Fail Overheat/Fan Fail and UID LED Connect an LED cable to pins 7 and 8 of the Front Control Panel to use the Overheat/Fan Fail LED connections.
  • Page 109: Hdd Led

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs HDD LED The HDD LED connection is located on pins 13 and 14 of JF1 on the X14SBI-TF motherboard.. Attach a cable to pin 14 to show storage drive activity status. For a detailed diagram of the X14SBI-TF motherboard, see the layout under "Motherboard...
  • Page 110: I/O Ports

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs I/O Ports Figure 4-1. X14SBI-TF I/O Ports I/O Ports Description Description BMC_LAN LAN2 USB0 (3.2 Gen 1) USB1 (3.2 Gen 1) UID Button LAN1 LAN Ports The motherboard has dual 1 GbE LAN ports (i210, ) or dual 10 GbE LAN ports (X550, ) located on the I/O panel.
  • Page 111: Usb Ports

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs LAN Ports BMC LAN Pin Definitions: 21 Total Pin Definitions: 19 Total Pin# Definition Pin# Definition Pin# Definition Pin# Definition TRD1P TRD4N Link 1000 LED (Amber) TRD1N TRCT4 Link 100 LED TRCT1 TRD5P...
  • Page 112: Unit Identifier Button

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs Unit Identifier Button A Unit Identifier (UID) button and two LED Indicators are located on the motherboard. The UID button is located near the I/O ports of the X14SBI-TF motherboard. Note: After pushing and holding the UID button for 12 seconds, all BMC settings including username and password will revert back to the factory default.
  • Page 113: Jumper Settings

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs Jumper Settings To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit board. See the diagram below for an example of jumping pins 1 and 2.
  • Page 114: I²C Buses For Vrm

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs Note: Clearing CMOS will also clear all passwords. 5. Remove the screwdriver (or shorting device). 6. Replace the cover, reconnect the power cord(s), and power on the system. I²C Buses for VRM Jumpers JVRM1 and JVRM2 allow the BMC to access CPU and memory VRM controllers.
  • Page 115: Led Indicators

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs TPM Enable/Disable Jumper Settings Jumper Setting Definition Pins 1–2 Enabled (Default) Pins 2–3 Disabled LED Indicators For information about the LED indicators on the SYS-212B-FLN2T server, refer to the following content. BMC Heartbeat LED A BMC Heartbeat LED is located on the X14SBI-TF motherboard.
  • Page 116: Onboard Power Led

    SuperServer SYS-212B-FLN2T: Motherboard Connections, Jumpers, and LEDs For a detailed diagram of the X14SBI-TF motherboard, see the layout under "Motherboard Quick Reference" on page M.2 LED State LED Color Definition Green: Blinking Device Working Onboard Power LED For a detailed diagram of the X14SBI-TF motherboard, see the layout under "Motherboard...
  • Page 117: Chapter 5: Software

    SuperServer SYS-212B-FLN2T: Software Chapter 5: Software After the SYS-212B-FLN2T server has been installed, you can install the Operating System (OS), configure RAID settings, and install the drivers. 5.1 Microsoft Windows OS Installation Installing the OS 5.2 Driver Installation 5.3 BMC...
  • Page 118: Microsoft Windows Os Installation

    USB flash or media drive, or the BMC KVM console. 2. Retrieve the proper drivers. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities," select the proper driver, and copy it to a USB flash drive.
  • Page 119 SuperServer SYS-212B-FLN2T: Software Figure 5-2. Loading the Driver Link To load the driver, browse the USB flash drive for the proper driver files. 5. Once all devices are specified, continue with the installation. 6. After the Windows OS installation has completed, the system will automatically reboot...
  • Page 120: Driver Installation

    SuperServer SYS-212B-FLN2T: Software 5.2 Driver Installation (missing or bad snippet)(missing or bad snippet) Figure 5-3. Driver & Tools Installation Screen...
  • Page 121: Bmc

    For security, each system is assigned a unique default BMC password for the ADMIN user. The password can be found on a sticker on the motherboard and a sticker on the chassis, for Supermicro chassis. The sticker also displays the BMC MAC address. If necessary, the password can be reset using the Supermicro IPMICFG tool.
  • Page 122: Chapter 6: Optional Components

    SuperServer SYS-212B-FLN2T: Optional Components Chapter 6: Optional Components This chapter describes alternate configurations and optional system components for the SYS- 212B-FLN2T server. 6.1 TPM Security Module 6.2 HBA Card 6.3 RAID Cards 6.4 Cable Management Arm Installing the Cable Management Arm Removing the Cable Management Arm 6.5 Intel Virtual RAID on CPU (VROC)
  • Page 123: Tpm Security Module

    SuperServer SYS-212B-FLN2T: Optional Components 6.1 TPM Security Module This is an SPI-capable TPM 2.0 with Infineon 9672 controller. The JTPM1 header is used to connect a Trusted Platform Module (TPM). A TPM is a security device that supports encryption and authentication in hard drives. It enables the X14SBI-TF motherboard to deny access if the TPM associated with the hard drive is not installed in the SYS-212B-FLN2T server.
  • Page 124: Hba Card

    This is a 12 Gb/s, multi-port SAS PCIe Gen 4.0 internal Host Bus Adapter (HBA) card. The Supermicro HBA AOC- S3816L- L16iT features 16 internal SAS connectors, while the AOC- S3808L- L8iT features eight internal SAS connectors. Both are designed for high- performance storage connectivity.
  • Page 125: Raid Cards

    SuperServer SYS-212B-FLN2T: Optional Components 6.3 RAID Cards These are Super Micro Computer, Inc. 12 Gb/s, multi-port PCIe Gen 4.0 RAID adapter cards. The low-profile AOC-S3908L-H8iR RAID card features eight internal SAS connectors and the AOC- S3916L- H16iR features 16 internal SAS connectors. Both offer high- performance storage connectivity.
  • Page 126: Cable Management Arm

    SuperServer SYS-212B-FLN2T: Optional Components 6.4 Cable Management Arm The SYS-212B-FLN2T server supports a cable management arm (CMA), which keeps the rear cables organized and clear of the rail mechanisms when the system is extended out the front of the rack for maintenance.
  • Page 127: Removing The Cable Management Arm

    SuperServer SYS-212B-FLN2T: Optional Components Figure 6-2. Installing the Connectors 3. Slide CMA connector #3 forward onto the two posts on the rear of the left middle rail. It snaps into place. 4. For CMA connector #4, align the metal tabs with the slots on the rear of the left outer rail and push it forward.
  • Page 128: Intel Virtual Raid On Cpu (Vroc)

    SuperServer SYS-212B-FLN2T: Optional Components 6.5 Intel Virtual RAID on CPU (VROC) ® Intel Virtual RAID on CPU (Intel VROC) is an enterprise RAID solution for NVMe SSDs directly attached to Intel Xeon Scalable processors. Intel Volume Management Device (VMD) is an integrated controller inside the CPU PCIe root complex.
  • Page 129: Hardware Key

    Hardware Key The Intel VROC hardware key is a license key that detects the Intel VROC SKU and activates the function accordingly. The key must be plugged into the Supermicro motherboard (connector JRK1). The key options are: ® Intel...
  • Page 130: Configuring Vmd Manually

    SuperServer SYS-212B-FLN2T: Optional Components The NVMe Mode Switch can be viewed or selected at BIOS > Advanced > Chipset Configuration > North Bridge > IIO Configuration > Intel® VMD Technology. Note: Without a VROC Key, there is no RAID support with the Auto switch. Only RAID 0 is supported with the VMD and Manual switches.
  • Page 131 SuperServer SYS-212B-FLN2T: Optional Components 4. VMD must only be enabled on NVMe port resources. If VMD is enabled on other PCIe ports, the functionality of those ports will be impacted. See the table below. Select “Intel VMD for Volume Management Device on” on Socket 0 (CPU1) or Socket 1 (CPU2) to enable VMD for devices under the respective CPU.
  • Page 132 SuperServer SYS-212B-FLN2T: Optional Components Figure 6-7. BIOS, Enabling VMD on Socket 1 (Example) 6. Enable the NVMe port resource according to table above for the NVMe drives that will be used in a RAID configuration. Figure 6-8. BIOS, Enabling Socket 1 (Example)
  • Page 133: Creating Nvme Raid Configurations

    SuperServer SYS-212B-FLN2T: Optional Components 7. Choose whether to make the NVMe drives in this IOU Hot Plug Capable by selecting Enabled or Disabled. 8. Repeat steps 4 through 7 for each IOU # on each CPU to enable VMD on the desired NVMe ports.
  • Page 134 SuperServer SYS-212B-FLN2T: Optional Components Figure 6-10. Creating Volume without enabling RAID spanned over VMD controller Figure 6-11. Creating Volume with enabling RAID spanned over VMD controller...
  • Page 135: Status Indications

    SuperServer SYS-212B-FLN2T: Optional Components 2. Set Name. 3. Set RAID Level. 4. If cross-controller RAID is required, select Enable RAID spanned over VMD Controller. 5. Select specific disks for RAID with an [X]. RAID0: Select at least two [2–24] disks RAID1: Select only two disks RAID5: Select at least three [3–24] disks...
  • Page 136: Hot-Plug

    SuperServer SYS-212B-FLN2T: Optional Components 3. Detach the device. Check link [3] below for details. 4. Physically remove the device. Hot-Plug Physically install the device. ESXi will automatically discover NVMe SSDs, but a manual scan may be required in some cases.
  • Page 137: Chapter 7: Troubleshooting And Support

    SuperServer SYS-212B-FLN2T: Troubleshooting and Support Chapter 7: Troubleshooting and Support The following content contains information on common issues and how to resolve them. 7.1 Online Resources Direct Links for the SYS-212B-FLN2T System Direct Links for General Support and Information 7.2 Baseboard Management Controller (BMC) 7.3 Troubleshooting Procedures...
  • Page 138: Online Resources

    SuperServer SYS-212B-FLN2T: Troubleshooting and Support 7.1 Online Resources A great deal of information is available on the Supermicro website. From the top menu of the Supermicro home page at https://www.supermicro.com: Specifications for servers and other hardware are available by clicking Products.
  • Page 139: Baseboard Management Controller (Bmc)

    SuperServer SYS-212B-FLN2T: Troubleshooting and Support 7.2 Baseboard Management Controller (BMC) The SYS-212B-FLN2T server supports the Baseboard Management Controller (BMC). BMC is used to provide remote access, monitoring, and management. There are several BIOS settings that are related to BMC. For general documentation and information on BMC, visit our website at the following page: https://www.supermicro.com/en/solutions/management-software/bmc-resources...
  • Page 140: Troubleshooting Procedures

    SuperServer SYS-212B-FLN2T: Troubleshooting and Support 7.3 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the "Technical Support Procedures" on page 146 section in this chapter. Always disconnect the AC power cord before adding, changing or installing any non hot-swap hardware components.
  • Page 141: Memory Errors

    BIOS installed in your system. 2. Memory support: Make sure that the memory modules are supported. Refer to the product page on our website at https://www.supermicro.com. Test the modules using memtest86 or a similar utility. Note: Click on the "Tested Memory List" link on the motherboard's product page to...
  • Page 142 SuperServer SYS-212B-FLN2T: Troubleshooting and Support 3. Storage Drive support: Make sure that all storage drives work properly. Replace the failed storage drives with good ones. 4. System cooling: Check the system cooling to make sure that all heatsink fans and processor/system fans, etc., work properly.
  • Page 143: Cmos Clear

    SuperServer SYS-212B-FLN2T: Troubleshooting and Support 7.4 CMOS Clear JBT1 on the X14SBI- TF motherboard is used to clear CMOS, which will also clear any passwords. For information on clearing CMOS, refer to "CMOS Clear" on page 113 earlier in this manual.
  • Page 144: Motherboard Battery

    SuperServer SYS-212B-FLN2T: Troubleshooting and Support 7.5 Motherboard Battery For information on removing, disposing of, and replacing the motherboard battery of your system, refer to "Motherboard Battery Removal and Installation" on page...
  • Page 145: Where To Get Replacement Components

    7.6 Where to Get Replacement Components If you need replacement parts for your SYS-212B-FLN2T server, to ensure the highest level of professional service and technical support, purchase exclusively from our Supermicro Authorized Distributors/System Integrators/Resellers. A list can be found on the Supermicro website: https://www.supermicro.com...
  • Page 146: Technical Support Procedures

    Before contacting Technical Support, take the following steps. Also, note that as a motherboard manufacturer, Supermicro also sells motherboards through its channels, so it is best to first check with your distributor or reseller for troubleshooting services. They should know of any possible problems with the specific system configuration that was sold to you.
  • Page 147 SuperServer SYS-212B-FLN2T: Troubleshooting and Support This warranty only covers normal consumer use and does not cover damages incurred in shipping or from failure due to the alternation, misuse, abuse or improper maintenance of products. During the warranty period, contact your distributor first for any product problems.
  • Page 148: Feedback

    SuperServer SYS-212B-FLN2T: Troubleshooting and Support 7.8 Feedback Supermicro values your feedback as we strive to improve our customer experience in all facets of our business. Email us at Techwriterteam@supermicro.com to provide feedback on our manuals.
  • Page 149: Chapter 8: Uefi Bios

    SuperServer SYS-212B-FLN2T: UEFI BIOS Chapter 8: UEFI BIOS The following content contains information on BIOS configuration with the SYS-212B-FLN2T server. 8.1 Introduction 8.2 Main Setup 8.3 Advanced Setup Configurations 8.4 Event Logs 8.5 BMC 8.6 Security 8.7 Boot 8.8 Save & Exit...
  • Page 150: Introduction

    SuperServer SYS-212B-FLN2T: UEFI BIOS 8.1 Introduction This chapter describes the AMIBIOS™ Setup utility for the motherboard. The BIOS is stored on a chip and can be easily upgraded using the UEFI script (flash.nsh), the BMC WebUI, or the SuperServer Automation Assistant (SAA) utility.
  • Page 151 SuperServer SYS-212B-FLN2T: UEFI BIOS The Main BIOS screen has two main frames. The left frame displays all the options that can be configured. “Grayed- out” options cannot be configured. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When a BIOS submenu or item is selected in the left frame, it is highlighted in white.
  • Page 152: Main Setup

    SuperServer SYS-212B-FLN2T: UEFI BIOS 8.2 Main Setup The Main setup screen appears when the AMI BIOS Setup utility is first entered. To return to the Main setup screen, select the Main tab at the top of the screen. The Main BIOS setup screen is shown below.
  • Page 153 SuperServer SYS-212B-FLN2T: UEFI BIOS Build Date This feature displays the date when the version of the BIOS ROM used in the system was built. CPLD Version This feature displays the version of the Complex-Programmable Logical Device (CPLD) used in the system.
  • Page 154: Advanced Setup Configurations

    SuperServer SYS-212B-FLN2T: UEFI BIOS 8.3 Advanced Setup Configurations Use the arrow keys to select the Advanced submenu and press <Enter> to access the submenu items. Important: Use caution when changing the Advanced settings. An incorrect value, an improper DRAM frequency, or a wrong BIOS timing setting may cause the system to malfunction.
  • Page 155: Cpu Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS are Disabled and Enabled. Note: BIOS POST messages are always displayed regardless of the setting of this feature. Bootup NumLock State Use this feature to set the Power-on state for the <Numlock> key. The options are On and Off.
  • Page 156 SuperServer SYS-212B-FLN2T: UEFI BIOS The following processor information is displayed: Processor BSP Revision Processor Socket Processor ID Processor Frequency Processor Max Ratio Processor Min Ratio Microcode Revision L1 Cache RAM (Per Core) L2 Cache RAM (Per Core) L3 Cache RAM (Per Package)
  • Page 157 SuperServer SYS-212B-FLN2T: UEFI BIOS DCU Streamer Prefetcher If this feature is set to Enabled, the Data Cache Unit (DCU) streamer prefetcher will prefetch data streams from the cache memory to the DCU to speed up data accessing and processing to enhance CPU performance. The options are Enabled, Disabled, and Auto.
  • Page 158 SuperServer SYS-212B-FLN2T: UEFI BIOS APIC Physical Mode Use this feature to enable the APIC physical destination mode. The options are Disabled and Enabled. (APIC is the abbreviation for Extended Advanced Programmable Interrupt Controller.) TXT Support Select Enabled to enable Intel Trusted Execution Technology (TXT) support to enhance system integrity and data security.
  • Page 159: Advanced Power Management Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Advanced Power Management Configuration Menu ►Advanced Power Management Configuration Latency Optimized Mode Select Enabled to set the power mode to the latency optimized mode to improve the latency. The options are Disabled and Enabled. This feature is motherboard-dependent.
  • Page 160: Cpu P State Control Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Select Performance to enhance system performance; however, this may consume more power as energy is needed to fuel the processors for operation. The options are Extreme Performance, Maximum Performance, Performance, Balanced Performance, Balanced Power, Power, and Max Power Efficient. Please note that the options of Extreme Performance and Max Power Efficient are motherboard-dependent.
  • Page 161 SuperServer SYS-212B-FLN2T: UEFI BIOS Notes: This feature is available when "SpeedStep (P-States)" is set to Enabled and when the number of SST-PP levels supported by your CPU is no less than two. This feature is NOT available when "Workload Profile" is set to Telco NFVI, Telco NFVI-FP, or Telco FlexRAN.
  • Page 162: Hardware Pm State Control Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS EIST PSD Function This feature reduces the latency that occurs when one P- state changes to another, thus allowing the transitions to occur more frequently. This will allow for more demand-based P- state switching to occur based on the real-time energy needs of applications so that the power- to-performance balance can be optimized for energy efficiency.
  • Page 163: Cpu C State Control Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS CPU C State Control Menu ►CPU C State Control Notes: This submenu is available when “Power Performance Tuning” is set to BIOS Controls EPB. This submenu is NOT available when “Workload Profile” is set to Telco NFVI, Telco NFVI-FP, or Telco FlexRAN.
  • Page 164: Cpu1 Core Disable Bitmap Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Package C State Use this feature to optimize and reduce CPU package power consumption in the idle mode. Please note that the changes you've made in this setting will affect all CPU cores or the circuits of the entire system.
  • Page 165: Uncore Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Uncore Configuration Menu ►Uncore Configuration The following information is displayed. Number of CPU Current UPI Link Speed Current UPI Link Frequency Global MMIO Low Base / Limit Global MMIO High Base / Limit PCIe Configuration Base / Size...
  • Page 166 SuperServer SYS-212B-FLN2T: UEFI BIOS latency. Select Auto for the KTI prefetcher to automatically preload the L1 cache with relevant data whenever it is needed. The options are Disabled, Enabled, and Auto. IO Directory Cache (IODC) This feature allows the IODC to generate snoops instead of generating memory lockups for remote IIO (InvIToM) and/or WCiLF (Cores).
  • Page 167: Memory Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS LLC Dead Line Alloc Select Enabled to optimally fill the dead lines in the LLC. The options are Disabled, Enabled, and Auto. SLF Enable(R1S) Use this feature to send B2P command for Pcode SLF Enable programming. This is enabled by default for supported CPU type.
  • Page 168: Memory Ras Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS DDR CXL Heterogeneous Interleave Support Select Enabled to support heterogeneous interleaving for physical DDR5 and CXL memory. The options are Disabled and Enabled. Memory RAS Configuration Menu ►Memory RAS Configuration Use this submenu to configure the memory mirroring, Reliability Availability Serviceability (RAS) settings.
  • Page 169 SuperServer SYS-212B-FLN2T: UEFI BIOS Note: This feature is available when "Memory PFA Support" is set to Disabled. Leaky Bucket Low Bit Use this feature to set the Low Bit value for the Leaky Bucket algorithm, which is used to check the data transmissions between CPU sockets and the memory controller.
  • Page 170: Security Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Security Configuration Menu ►Security Configuration ---------------------------------------------------------------- Memory Encryption (TME) [Outputs] ---------------------------------------------------------------- The following information is displayed. MSE activation state MK-TME activation state CI activation state Cryptographic Algorithm configured ---------------------------------------------------------------- Memory Encryption (TME) [Inputs] ---------------------------------------------------------------- Memory Encryption (TME) Select Enabled for Intel Total Memory Encryption (TME) support to enhance memory data security.
  • Page 171 SuperServer SYS-212B-FLN2T: UEFI BIOS ---------------------------------------------------------------- The following information is displayed. TDX activation state ---------------------------------------------------------------- Trust Domain Extensions (TDX) [Inputs] ---------------------------------------------------------------- ---------------------------------------------------------------- Software Guard Extensions (SGX) [Inputs] ---------------------------------------------------------------- The following features are available when your motherboard supports SGX. Note: To support SGX features, DIMM population must be symmetric across Integrated Memory Controllers (IMCs) and eight DIMMs per socket at least.
  • Page 172 SuperServer SYS-212B-FLN2T: UEFI BIOS ---------------------------------------------------------------- Processor Reserved Memory [Capabilities] ---------------------------------------------------------------- The following information is displayed. PRMRR Min Size per domain PRMRR Max Size per domain ---------------------------------------------------------------- Processor Reserved Memory [Outputs] ---------------------------------------------------------------- The following information is displayed. PRMRR Size per domain...
  • Page 173 SuperServer SYS-212B-FLN2T: UEFI BIOS SGX Factory Reset Use this feature to perform an SGX factory reset to delete all registration data and force an Initial Platform Establishment flow. Reboot the system for the changes to take effect. The options are Disabled and Enabled.
  • Page 174 SuperServer SYS-212B-FLN2T: UEFI BIOS Note: This feature is available when "SW Guard Extensions (SGX)" is set to Enabled. This feature is NOT available when "Select Owner EPOCH Input Type" is set to SGX Owner EPOCH deactivated. Software Guard Extensions Epoch 1 Use this feature to enter the EPOCH value.
  • Page 175: Iio Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS IIO Configuration Menu ►IIO Configuration PCIe Completion Timeout Use this feature to set the PCIe completion timeout. The options are 50us to 50ms, 50us to 100us, 1ms to 10ms, 16ms to 55ms, 65ms to 210ms, 260ms to 900ms, 1s to 3.5s, and Disabled.
  • Page 176 SuperServer SYS-212B-FLN2T: UEFI BIOS Notes: This feature is available when "NVMe Mode Switch" is set to Manual. After you’ve enabled VMD in the BIOS on a PCIe slot, this PCIe slot will be dedicated for VMD use only, and it will no longer support any PCIe device. To re- activate this slot for PCIe use, disable VMD in the BIO.
  • Page 177: Intel Vt For Directed I/O (Vt-D) Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Disabled and Enabled. Equalization Bypass To Highest Rate Set this feature to Enabled to reduce the link training time for PCIe 5.0 device by skipping equalization of intermediate data rates. The options are Disabled and Enabled.
  • Page 178: Trusted Computing Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Gen4 Link Degradation Use this feature to enable PCIe Gen4 link degradation. The options are Disabled and Enabled. Note: The default setting is Enabled when your motherboard supports PCIe Gen4 link. Otherwise, the default setting is Disabled.
  • Page 179 SuperServer SYS-212B-FLN2T: UEFI BIOS SHA-1 PCR Bank (Available when "Security Device Support" is set to Enabled) Select Enabled to enable SHA-1 PCR Bank support to enhance system integrity and data security. The options are Disabled and Enabled. SHA256 PCR Bank (Available when "Security Device Support" is set to Enabled) Select Enabled to enable SHA256 PCR Bank support to enhance system integrity and data security.
  • Page 180: Acpi Settings Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS which allows the user to independently enable "flag, policy, and authorization values" without involving other hierarchies. A user with privacy concerns can disable the endorsement hierarchy while still using the storage hierarchy for TPM applications, permitting the platform software to use the TPM.
  • Page 181: Super Io Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Super IO Configuration Menu ►Super IO Configuration The following information is displayed. Super IO Chip Note: This submenu is available when your system supports this feature. Serial Port 1 Configuration Menu ►Serial Port 1 Configuration Serial Port 1 Select Enabled to enable serial port 1.
  • Page 182: Serial Port Console Redirection Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Change Settings (Available when "Serial Port 2/SOL" above is set to Enabled) Use this feature to specify the base I/O port address and the Interrupt Request address of serial port 2 (or SOL). Select Auto for the BIOS to automatically assign the base I/O and IRQ address to serial port 2 (or SOL).
  • Page 183 SuperServer SYS-212B-FLN2T: UEFI BIOS Terminal Type Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT- UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes.
  • Page 184 SuperServer SYS-212B-FLN2T: UEFI BIOS Resolution 100x31 Select Enabled for extended- terminal resolution support. The options are Disabled and Enabled. Putty KeyPad Use this feature to select function key and keypad settings on Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SCO, ESCN, and VT400.
  • Page 185: Network Stack Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Data Bits EMS Parity EMS Stop Bits EMS Network Stack Configuration Menu ►Network Stack Configuration Network Stack Select Enabled to enable Preboot Execution Environment (PXE) or Unified Extensible Firmware Interface (UEFI) for network stack support. The options are Disabled and Enabled.
  • Page 186: Mac:(Mac Address)-Ipv4 Network Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS MAC:(MAC address)-IPv4 Network Configuration Menu ►MAC:(MAC address)-IPv4 Network Configuration Configured Enable this feature to configure network addresses for DHCP, local IP address, local netmask, local gateway, and local DNS server. The options are Disabled and Enabled.
  • Page 187: Advanced Configuration

    SuperServer SYS-212B-FLN2T: UEFI BIOS Host address Route Table Gateway addresses DNS addresses Interface ID Use this feature to change/enter the 64-bit alternative interface ID for the device. The string format is colon separated. The default setting is the MAC address above.
  • Page 188 SuperServer SYS-212B-FLN2T: UEFI BIOS PCI Devices Common Settings: Re-Size BAR Support Use this feature to enable the Resizable BAR support. Resizable BAR is a PCIe interface technology that allows the CPU to access to the entire frame buffer. With this technology, your system will be able to handle multiple CPU to GPU transfers simultaneously rather than queuing, which can improve the frame rate performance.
  • Page 189: Http Boot Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS NVMe Firmware Source Use this feature to select the NVMe firmware to support system boot. The options are Vendor Defined Firmware and AMI Native Support. The option of Vendor Defined Firmware is pre- installed on the drive and may resolve errata or enable innovative functions for the drive. The default option, AMI Native Support, is offered by the BIOS with a generic method.
  • Page 190 HTTPS Boot Checks Hostname Important: Disabling "HTTPS Boot Checks Hostname" is a violation of RFC 6125 and may expose you to Man-in-the-Middle Attacks. Supermicro is not responsible for any and all security risks incurred by you disabling this feature. Enable this feature for HTTPS boot to check the hostname of the TLS certificates to see if it matches the host name provided by the remote server.
  • Page 191: Supermicro Kms Server Configuration Menu

    Supermicro KMS TCP Port number Use this feature to set the TCP port number used in the Supermicro KMS server. The valid range is 100–9999. The default setting is 5696. Do not change the default setting unless a different TCP port number has been specified and used in the Supermicro KMS server.
  • Page 192: Super-Guardians Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Use the three features above to enroll factory defaults or load the KMS Transport Layer Security (TLS) certificates, which are generated by the KMS server, from the file stored in the USB flash drive as shown below.
  • Page 193 Notes: Be sure that the KMS server is ready before configuring this feature. Use the professional KMS server solutions (e.g., Thales Server) or the Supermicro PyKMIP Software Package to establish the KMS server. KMS Server Retry Count (Available when "TPM Security Policy" and "USB Security Policy"...
  • Page 194: System Diagnostics Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Notes: Be sure to connect a USB flash drive with the Authentication-Key (filename: TPMAuth.bin) to your system before the system reboot. Be sure to save the Authentication-Key (filename: TPMAuth.bin) to the USB flash drive and keep a backup. Load the Authentication-Key (filename: TPMAuth.bin) after the TPM (either onboard or external) is detected by your system.
  • Page 195: Intel(R) Ethernet Controller Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS Note: Pressing <F7> during system bootup can also launch system diagnostics. Intel(R) Ethernet Controller Menu ►Intel(R) Ethernet Controller (Ethernet controller) - (MAC address) Notes: The Ethernet controller and MAC address shown above are based on your system features.
  • Page 196: Tls Authenticate Configuration Menu

    SuperServer SYS-212B-FLN2T: UEFI BIOS UEFI Driver Adapter PBA Device Name Chip Type PCI Device ID PCI Address Link Status MAC Address Virtual MAC Address TLS Authenticate Configuration Menu ►TLS Authenticate Configuration Use this submenu to configure Transport Layer Security (TLS) settings.
  • Page 197: Asmedia Ahci Controller

    SuperServer SYS-212B-FLN2T: UEFI BIOS Asmedia AHCI Controller ►Asmedia AHCI Controller The following information is displayed. SATA Port 0 SATA Port 1 SATA Port 2 SATA Port 3 Driver Health Menu ►Driver Health This feature displays the health information of the drivers installed in your system, including LAN controllers, as detected by the BIOS.
  • Page 198: Event Logs

    SuperServer SYS-212B-FLN2T: UEFI BIOS 8.4 Event Logs Use this menu to configure Event Logs settings. Note: After making any changes in this section, please be sure to reboot the system for the changes to take effect. Figure 8-3. Event Logs Screen ►Change SMBIOS Event Log Settings...
  • Page 199: View Smbios Event Log

    SuperServer SYS-212B-FLN2T: UEFI BIOS Erasing Settings Erase Event Log (Available when "SMBIOS Event Log" is set to Enabled) Select No to keep the event log without erasing it upon next system bootup. Select (Yes, Next reset) to erase the event log upon next system reboot. The options are No, (Yes, Next reset), and (Yes, Every reset).
  • Page 200: Bmc

    SuperServer SYS-212B-FLN2T: UEFI BIOS 8.5 BMC Use this menu to configure Baseboard Management Console (BMC) settings. Figure 8-4. BMC Screen BMC Firmware Revision This feature indicates the BMC firmware revision used in this system. BMC STATUS This feature indicates the status of the BMC firmware installed in this system.
  • Page 201: Security

    SuperServer SYS-212B-FLN2T: UEFI BIOS 8.6 Security Use this menu to configure the following security settings for the system. Figure 8-5. Security Screen Disable Block Sid and Freeze Lock (Available when your storage devices support TCG) Select Enabled to allow SID authentication to be performed in TCG storage devices. The options are Disabled and Enabled.
  • Page 202 SuperServer SYS-212B-FLN2T: UEFI BIOS User Password (Available when "Administrator Password" has been set) This feature indicates if a user password has been installed. Use this feature to set the user password which is required to enter the BIOS Setup utility. The length of the password can be between three and 20 characters long.
  • Page 203: Boot

    SuperServer SYS-212B-FLN2T: UEFI BIOS 8.7 Boot Use this menu to configure Boot settings. Figure 8-6. Boot Screen FIXED BOOT ORDER Priorities Use this feature to prioritize the order of a bootable device from which the system will boot. Press <Enter> on each item sequentially to select the device.
  • Page 204 SuperServer SYS-212B-FLN2T: UEFI BIOS Path for boot option Use this feature to enter the path for the new boot option in the format fsx:\path\filename.efi. Boot option File Path Use this feature to specify the file path for the new boot option.
  • Page 205: Save & Exit

    SuperServer SYS-212B-FLN2T: UEFI BIOS 8.8 Save & Exit Select Save & Exit from the BIOS Setup screen to configure the settings below. Figure 8-7. Save & Exit Screen Save Options Discard Changes and Exit Use this feature to exit from the BIOS Setup utility without making any permanent changes to the system configuration and reboot the computer.
  • Page 206 SuperServer SYS-212B-FLN2T: UEFI BIOS Discard Changes Select this feature and press <Enter> to discard all changes made and return to the BIOS Setup utility. Default Options Restore Optimized Defaults Select this feature and press <Enter> to load manufacturer optimized default settings, which are intended for maximum system performance but not for maximum stability.
  • Page 207: Appendix A: Bios Codes

    SuperServer SYS-212B-FLN2T: BIOS Codes Appendix A: BIOS Codes For information about BIOS codes for the SYS- 212B- FLN2T server, refer to the following content. BIOS Error POST (Beep) Codes During the Power-On Self-Test (POST) routines, which are performed each time the system is powered on, errors may occur.
  • Page 208: Appendix B: Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this section in its entirety before installing or configuring components in the Supermicro SYS-212B-FLN2T server. These warnings may also be found on our website at the following page: https://www.supermicro.com/about/policies/safety_information.cfm...
  • Page 209 SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems 此警 告符 號代 表危 險 。 您 正 處 於 可 能 身 體 可 能 會 受 損 傷 的 工 作 環 境 中 。 在 您 使 用 任 何 設 備 之 前 , 請 注 意 觸 電 的...
  • Page 210: Installation Instructions

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems ‫אזהרה‬ ‫הצהרות‬ ‫תקנון‬ ‫חבלה‬ ‫מפני‬ ‫המשתמש‬ ‫את‬ ‫להזהיר‬ ‫מנת‬ ‫על‬ ,‫התעשייה‬ ‫תקני‬ ‫פי‬ ‫על‬ ‫אזהרות‬ ‫הן‬ ‫הבאות‬ ‫הצהרות‬ ‫תמיכה‬ ‫מחלקת‬ ‫עם‬ ‫קשר‬ ‫ליצור‬ ‫יש‬ ,‫כלשהי‬ ‫בבעיה‬ ‫היתקלות‬ ‫או‬ ‫שאלות‬ ‫ויש‬ ‫במידה‬ .‫אפשרית‬...
  • Page 211: Circuit Breaker

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems 設置 手順 書 システムを電源 に接続する前 に、 設置 手順 書をお読 み下さ い。 警告 将此 系统 连接 电源 前,请先 阅读 安装 说明 。 警告 將系 統與 電源 連接 前, 請先 閱讀 安裝 說明 。...
  • Page 212 SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems サーキッ ト ・ ブレーカ ー こ の製品 は、 短 絡( 過 電流 ) 保 護装 置がある建 物での設置 を前提 と し ています。 保護 装置 の定格 が250 V、 20 Aを超えないこ と を確認 下さ い。...
  • Page 213: Power Disconnection Warning

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장 치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie.
  • Page 214: Equipment Installation

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema.
  • Page 215 SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems 機器 の設置 トレーニングを受 け認 定 さ れた人 だけがこ の装 置 の設 置 、 交 換 、 またはサービスを許 可 さ れていま す。 警告 只有 经过 培训 且具 有资 格的 人员 才能 进行 此设 备的安 装 、 更换 和维 修 。...
  • Page 216: Rack Stability Hazard

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems Waarschuwing Alleen geautoriseerd personeel en gekwalificeerd onderhoudspersoneel mag deze apparatuur installeren, vervangen of onderhouden. Rack Stability Hazard Warning! Stability hazard. The rack may tip over causing serious personal injury. Before extending the rack to the installation position, read the installation instructions.
  • Page 217 SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems ¡Advertencia! Peligro de inestabilidad. El rack podría volcarse y causar lesiones personales graves. Antes de extender el rack a la posición de instalación, lea las instrucciones de instalación. No coloque ninguna carga sobre el equipo montado sobre rieles deslizantes en la posición de instalación.
  • Page 218: Restricted Area

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems Waarschuwing Gevaar voor instabiliteit. Het rek kan kantelen en ernstig persoonlijk letsel veroorzaken. Lees de installatie-instructies voordat u het rek uitschuift naar de installatiepositie. Plaats geen last op de op de glijrail gemonteerde apparatuur in de installatiepositie. Laat de op de glijrail gemonteerde apparatuur niet in de installatiepositie staan.
  • Page 219: Battery Handling

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 220 SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems 電池 の取り 扱 い バッ テリ ーを間 違 っ たタ イ プに交 換 すると 爆 発 の危 険 があり ます。 交 換 する電 池 はメ ーカ ーが推 奨 す る型 、 または同等 のものを使 用下 さ い。 使用 済電 池は製 造元 の指示 に従 っ て処分 し て下 さ い。...
  • Page 221: Redundant Power Supplies

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems ‫ﺻﺤﻴﺢ‬ ‫ﻏﻴﺮ‬ ‫ﺑﻨﻮع‬ ‫اﻟﺒﻄﺎرﻳﺔ‬ ‫اﺳﺘﺒﺪال‬ ‫ﺗﻢ‬ ‫إذا‬ ‫اﻻﻧﻔﺠﺎر‬ ‫ﺧﻄﺮ‬ ‫ﻫﻨﺎك‬ ‫اﻟﺒﻄﺎرﻳﺔ‬ ‫اﺳﺤﺒﺬال‬ ‫اﻟﻤﺼﻨﻌﺔ‬ ‫اﻟﺸﺮﻣﺔ‬ ‫ﺑﻪ‬ ‫أوﺻﺚ‬ ‫ﻣﻤﺎ‬ ‫ﻳﻌﺎدﻟﻬﺎ‬ ‫ﻣﺎ‬ ‫أو‬ ‫اﻟﻨﯩﻊ‬ ‫ﺑﻨﻔﺲ‬ ‫ﻓﻘﻂ‬ ‫اﻟﺼﺎﻧﻌﺔ‬ ‫اﻟﺸﺮﻣﺔ‬ ‫ﻟﺤﻌﻠﻴﻤﺎت‬ ‫وﻓﻘﺎ‬ ‫اﻟﻤﺴﺤﻌﻤﻠﺔ‬ ‫اﻟﺒﻄﺎرﻳﺎت‬ ‫ﻣﻦ‬ ‫ﺟﺨﻠﺺ‬ 경고! 배터리를...
  • Page 222: Backplane Voltage

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden. ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones.
  • Page 223 SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems バッ ク プレーンの電圧 システムの稼働 中は危 険な電 圧または電力 が、 バッ ク プレーン上 にかかっ ています。 修理 する際には注 意く ださ い。 警告 当系 统正 在进 行时 , 背 板上 有很 危险 的电压 或能 量, 进行 维修 时务 必小 心 。...
  • Page 224: Comply With Local And National Electrical Codes

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is. Voorzichtigheid is geboden tijdens het onderhoud.
  • Page 225: Product Disposal

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems ‫הארצי‬ ‫החשמל‬ ‫חוקי‬ ‫תיאום‬ !‫אזהרה‬ ‫והארציים‬ ‫המקומיים‬ ‫החשמל‬ ‫לחוקי‬ ‫תואמת‬ ‫להיות‬ ‫חייבת‬ ‫הציוד‬ ‫התקנת‬ ‫اﻟﻤﺘﻌﻠﻘﺔ‬ ‫واﻟﯩﻄﯩﻴﺔ‬ ‫اﻟﻤﺤﻠﻴﺔ‬ ‫ﻟﻠﻘﯩﺎوﻳﻪ‬ ‫ﻳﻤﺘﺜﻞ‬ ‫أن‬ ‫ﻳﺠﺐ‬ ‫اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫اﻟﻤﻌﺪات‬ ‫ﺗﺮﻛﻴﺐ‬ ‫ﺑﺎﻟﻜﻬﺮﺑﺎء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다.
  • Page 226 SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement.
  • Page 227 SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems フ ァ ンの警 告 警 告 ! 回 転 部 品 に注 意 。 運 転 中 は回 転 部 (羽 根)に触 れないでく ださ い。 シャ ーシから 冷 却 フ ァ ン...
  • Page 228: Power Cable And Ac Adapter

    SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems !‫אזהרה‬ ‫חלקי‬ ‫את‬ ‫מסירים‬ ‫בפעולהכאשר‬ ‫המאוורר‬ ‫מלהבי‬ ‫התרחק‬ .‫מסוכנים‬ ‫נעים‬ ‫חלקים‬ ‫את‬ ‫בטוח‬ ‫למרחק‬ ‫להרחיק‬ ‫יש‬ .‫עובדים‬ ‫עדיין‬ ‫והמאווררים‬ ‫יתכן‬ ,‫מהמארז‬ ‫המאוורר‬ ‫המאוורר‬ ‫בתוך‬ ‫מהפתחים‬ ‫שונים‬ ‫עבודה‬ ‫וכלי‬ ‫האצבעות‬ ‫أن‬ ‫اﻟﻤﻤﻜﻦ‬ ‫اﻟﻤﺘﺤﺮﻛﺔ.ﻣﻦ‬...
  • Page 229 遵 照 当 地 法 规 和 安 全 要 求 的 合 规 的 电 源 线 尺 寸 和 插 头.使 用 其 它 线 材 或 适 配 器 可 能 会 引 起 故 障 或 火 灾 。 除 了 Supermicro所 指 定 的 产 品,电 气 用 品 和 材 料 安 全 法 律 规 定 禁 止 使 用...
  • Page 230 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시 오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법 은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다.
  • Page 231 SuperServer SYS-212B-FLN2T: Standardized Warning Statements for AC Systems Stroomkabel en AC-Adapter Waarschuwing! Bij het aansluiten van het Product uitsluitend gebruik maken van de geleverde Kabels of een andere geschikte aan te schaffen Aansluitmethode, deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen, inclusief de juiste kabeldikte en stekker. Het gebruik van niet geschikte Kabels en/of Adapters kan een storing of brand veroorzaken.
  • Page 232: System Specifications

    SuperServer SYS-212B-FLN2T: System Specifications Appendix C: System Specifications Processors Single Socket E2 (LGA-4710) Intel® Xeon® 6700/6500 series processors with P-cores or 6700 series processors with E-cores Chipset System on chip BIOS AMI 64MB UEFI Memory 8 DIMMs Max Memory (1DPC): Up to 2TB 6400MT/s ECC DDR5 RDIMM...
  • Page 233 SuperServer SYS-212B-FLN2T: System Specifications Chassis Height: 3.5" (89 mm) Width: 17.2" (437 mm) Depth: 17.72" (450 mm) Package: 14.57" (H) x 23.23" (W) x 26.18" (D) Gross Weight: 23 lbs (10.43 kg) Net Weight: 17 lbs (7.7 kg) System Cooling...
  • Page 234 SuperServer SYS-212B-FLN2T: General Data Center Environmental Specifications Appendix D: General Data Center Environmental Specifications Particulate Contamination Specifications Air filtration: Data centers must be kept clean to Class 8 of ISO 14644-1 (ISO 2015). The air entering the data center should be filtered with a MERV 11 filter or better.