Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Kistler Manuals
Security Sensors
9333A
Instruction manual
Kistler 9333A Instruction Manual
Press force sensor
Hide thumbs
1
2
3
Table Of Contents
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
page
of
78
Go
/
78
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Introduction
Important Notes
For Your Safety
Unpacking
Notes on Using the Press Force Sensor
Hints on Using this Instruction Manual
General Description
What Are Press Force Sensors Used for
Design and Functional Principle of the Press Force Sensor Type 9323AAA, 9323AA, 9323A, 9333A, 9343A, 9363A, 9383A, 9393A
Installation and Startup
Important Information
Mounting of the Press Force Sensor
Overview of Adaptation Possibilities Type 9323AAA
Adaption A: Mounting Via Integrated Threated Bushing with Mounting Screw
Adaptation B: Mounting Via Integrated Fine Thread
Adaptation C: Mounting Via Adapter with Straight Shank Slot
Adaptation D: Mounting Via Thread Adapter
Adaptation E: Mounting Via Adaptation Plate/Flange
Adaptation F: Mounting Via Integrated Flange
Adaptation G: Deep Drawing Tool with Centric Ejection Tool
Adaptation H: Punch with Centric Ejection Bore
Adaptation I: Riveting Tool
Adaptation J: Calibration Element with Pressure Distribution Cap and Flange
Basic Circuit and Cabling of the Measuring Chain
Notes on Cabling the Measuring Chain
Measurement Range and Actuating Variables
Calculation Example
Operation
Setting the Charge Amplifier
Polarity of the Measuring Signal
Resolution of the Measuring Signal
Quasistatic Measurements
Tips for Good Measurands
Calibration and Maintenance
In-Situ Calibration of Force Sensors
Working Point Calibration by Peak Value Comparison
Test System Requirements
Reference Press Force Sensor (PFS) Installation
Load Application
Calibration Process Worksheet
Kistler Calibration Service
Maintenance Work
Troubleshooting
Fault-Finding and Remedy
Repairing the Press Force Sensor
Technical Data
Type 9323A/AA/AAA, 9333A, 9343A, 9363A, 9383A, 9393A
Press Force Sensor Typ 93X3Au0109
Dimensions Type 9323A/AA/AAA, 9333A, 9343A, 9363A, 9383A, 9393A
Dimensions Included Accessories
Threaded Bushing for Type 9323A/AA/AAA, 9333A, 9343A, 9363A, 9383A
Centering Ring for Type 9323A/AA/AAA, 9333A, 9343A, 9363A, 9383A, 9393A
Hexagon Socket Screw for Type 9323A/AA/AAA, 9333A, 9343A, 9363A, 9383A, 9393A
Included Accessories
Dimensions of Optional Accessories
Flange for Type 9323A/AA/AAA, 9333A, 9343A, 9363A, 9383A, 9393A
Force Distribution Cap for Type 9323A/AA, 9333A, 9343A, 9363A, 9383A, 9393A
Female Thread Adapter for Type 9323A/AA/AAA, 9333A, 9343A, 9363A, 9383A, 9393A
Male Thread Adapter for Type 9323A/AA/AAA, 9333A, 9343A, 9363A, 9383A, 9393A
Optional Accessories
Annex
Glossary
Measurement Uncertainty
Linearity
Frequency Range
Influence of Temperature
Index
Advertisement
Quick Links
1
Design and Functional Principle of the Press Force Sensor Type 9323Aaa, 9323Aa, 9323A, 9333A, 9343A, 9363A, 9383A, 9393A
Download this manual
F
z
Instruction
Manual
Press Force Sensor
Type 9323AA, 9323A,
Type 9323AAA,
9333A, 9343A, 9363A,
9323AA, 9323A,
9383A, 9393A
9333A, 9343A,
9363A, 9383A,
9393A
9323A_002-476e-11.24
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the 9333A and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Kistler 9333A
Security Sensors Kistler 9329A Instruction Manual
Reaction torque sensors (53 pages)
Security Sensors Kistler 9345B Instruction Manual
2-component sensor fz, mz (65 pages)
Security Sensors Kistler 9306A Instruction Manual
6-axis force/ moment sensor (42 pages)
Security Sensors Kistler 9306A Instruction Manual
6-axis force/torque sensor (43 pages)
Security Sensors Kistler 9323AAA Instruction Manual
Press force sensor (78 pages)
Security Sensors Kistler 9343A Instruction Manual
Press force sensor (78 pages)
Security Sensors Kistler 9363A Instruction Manual
Press force sensor (78 pages)
Security Sensors Kistler 9819A Series Instruction Manual
Press force sensor, retrofitset (52 pages)
Security Sensors Kistler 6021B Series Instruction Manual
High temperature pressure sensor (22 pages)
Security Sensors Kistler CHFA Series Instruction Manual
Hf sensors, optical laser height sensors (43 pages)
Security Sensors Kistler 8852A Series Instruction Manual
Atex/csa hazardous area system: ae-piezotron® sensor (40 pages)
Security Sensors Kistler 6052 Series Instruction Manual
Uncooled piezoelectric pressure sensors (25 pages)
Security Sensors Kistler 5335A Series Instruction Manual
Correvit l-motion non-contact optical sensors (79 pages)
Security Sensors Kistler Correvit SFII Instruction Manual
Non-contact optical sensors, type csf2a (60 pages)
Security Sensors Kistler 6213B Instruction Manual
High-pressure quartz sensors (27 pages)
Security Sensors Kistler 6635A1 Instruction Manual
Cylinder pressure sensor (20 pages)
Summarization of Contents
Introduction to Press Force Sensors
Important Safety and Usage Notes
Sensor Safety Precautions
Safety instructions for handling the press force sensor.
Sensor and Accessory Unpacking
Procedures for checking and unpacking the sensor and accessories.
Press Force Sensor Usage Guidelines
Guidelines for correct operation and handling of the sensor.
Instruction Manual Usage Tips
Advice on how to effectively use the manual.
General Press Force Sensor Description
Press Force Sensor Applications
Applications and use cases of press force sensors.
Sensor Design and Functional Principle
Explanation of the sensor's construction and operational mechanism.
Sensor Installation and Startup Procedures
Key Installation Information
Crucial points for handling and installing the precision instrument.
Press Force Sensor Mounting
Detailed instructions for proper sensor installation and seating.
Adaptation Possibilities Overview
Summary of various mounting methods for the sensors.
Adaptation A: Threaded Bushing Mounting
Method for mounting using a threaded bushing and screw.
Adaptation B: Integrated Fine Thread Mounting
Mounting method utilizing an integrated fine thread.
Adaptation C: Straight Shank Slot Mounting
Mounting using an adapter with a straight shank slot.
Adaptation D: Thread Adapter Mounting
Mounting method employing a thread adapter.
Adaptation E: Plate/Flange Mounting
Mounting using a plate or flange for flat mounting.
Adaptation F: Integrated Flange Mounting
Mounting method using an integrated flange.
Adaptation G: Deep Drawing Tool Mounting
Mounting for deep drawing with an ejection tool.
Adaptation H: Punch Ejection Bore Mounting
Mounting using a punch with a centric ejection bore.
Adaptation I: Riveting Tool Mounting
Mounting for riveting applications.
Adaptation J: Calibration Element Mounting
Mounting using a calibration element with cap and flange.
Measuring Chain Circuit and Cabling
Information on the electrical connections and wiring of the system.
Cabling the Measuring Chain
Specific guidance for connecting the sensor cable to the amplifier.
Measurement Range and Actuating Variables
Calculation Example for Measurement Limits
Example demonstrating calculation of measurement limits and variables.
Sensor Operation
Setting the Charge Amplifier
Procedures for configuring the charge amplifier for sensor operation.
Measuring Signal Polarity
Explanation of signal polarity from compressive forces.
Measuring Signal Resolution
Defining and calculating the smallest measurable change in a signal.
Quasistatic Measurement Considerations
Handling and considerations for static measurements with piezoelectric sensors.
Tips for Good Measurements
Best practices for obtaining accurate and reliable measurement results.
Calibration and Maintenance
In-situ Force Sensor Calibration
Methods for calibrating sensors directly within the measurement setup.
Calibration Test System Requirements
Necessary components and setup for the calibration test system.
Reference Sensor Installation
Proper installation of the reference sensor for calibration.
Calibration Load Application
Procedure for applying and recording loads during calibration.
Calibration Process Worksheet
Step-by-step guide and template for the calibration process.
Kistler Calibration Services
Overview of calibration services offered by Kistler.
Sensor Maintenance Work
Guidelines for maintaining the press force sensor for reliable operation.
Troubleshooting Sensor Issues
Fault Finding and Remedies
Common issues, their causes, and solutions for sensor malfunctions.
Press Force Sensor Repair
Information on when repair is not possible and factory service.
Press Force Sensor Technical Data
Technical Data for Sensor Types
Detailed technical specifications for various sensor models.
Technical Data for 93x3AU0109 Series
Specific technical data for the 93x3AU0109 sensor series.
Sensor Dimensional Drawings
Dimensional drawings and data for the sensor types.
Dimensions of Included Accessories
Dimensions of accessories that are shipped with the sensors.
Threaded Bushing Dimensions
Dimensions of the threaded bushing accessory.
Centering Ring Dimensions
Dimensions of the centering ring accessory.
Hexagon Socket Screw Dimensions
Dimensions of hexagon socket screws included with sensors.
List of Included Accessories
List of accessories included with each force sensor model.
Optional Accessories Dimensions
Dimensions for optional accessories available for the sensors.
Flange Dimensions
Dimensions of flanges for mounting the sensors.
Force Distribution Cap Dimensions
Dimensions of force distribution caps.
Female Thread Adapter Dimensions
Dimensions of female thread adapters.
Male Thread Adapter Dimensions
Dimensions of male thread adapters.
Other Optional Accessories
List of other optional accessories and their types.
Annex and Glossary
Technical Glossary
Definitions of technical terms used in the manual.
Measurement Uncertainty Factors
Discussion of systematic and random errors affecting measurement accuracy.
Sensor Linearity Explained
Explanation of sensor linearity and the best straight line definition.
Sensor Frequency Range
Analysis of sensor frequency response and its limitations.
Temperature Influence on Sensor
How temperature affects sensor output and measurement accuracy.
Table of Contents
Save PDF
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the 9333A and is the answer not in the manual?
Questions and answers