Programmable linear dc power supply

Advertisement

Quick Links

SPD4000X Series
Programmable Linear
DC Power Supply
QuickStart
EN01A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPD4121X and is the answer not in the manual?

Questions and answers

Summarization of Contents

General Safety Summary
Power Cord and Fuse Safety
Covers proper power cord usage and correct fuse types for safety.
Electrical Safety and Grounding
Details importance of proper grounding and observing terminal ratings to prevent shock.
Ventilation and Malfunction Handling
Advises on ventilation and seeking maintenance for malfunctioning products.
Operating Environment and Warnings
Guides on operating conditions, ventilation, and avoiding hazardous environments.
Safety Terms and Symbols
Explains hazard terminology and relevant safety symbols.
General Care and Cleaning
Care and Cleaning Procedures
Covers instrument storage recommendations and cleaning methods.
General Inspection
Shipping Container, Instrument, and Accessories Check
Guides on inspecting the shipping container, instrument, and accessories.
Considerations
Input Power and Electrical Checks
Details input power requirements and essential electrical checks before operation.
Preparation Before Use
AC Power Connection and Output Verification
Steps for connecting power and checking voltage/current output functionality.
Panel Introduction
Front and Rear Panel Components
Identifies and describes the key components of the front and rear panels.
User Interface Overview
Source and Configure Menu Options
Explains accessing settings for output parameters and configurations.
List, Waveform, and Menu Navigation
Covers list settings, waveform display, and general menu navigation.
Sense Mode Configuration
Details setting the 4W sense mode for specific channels.
Basic Operation
Output Mode Setting
Explains independent, parallel, and series output modes for channels.
Constant Voltage/Current Mode
Details operation in Constant Voltage (CV) and Constant Current (CC) modes.
Independent Output Mode
Describes setting and using channels in independent output mode.
CH2/CH3 Parallel Mode
Steps to configure and use CH2/CH3 in parallel mode for increased current.
CH2/CH3 Series Mode
Steps to configure and use CH2/CH3 in series mode for increased voltage.
4W Sense Mode
Details the activation and use of 4W sense mode for accurate voltage delivery.
Save and Recall Settings
Covers saving and recalling instrument settings to internal or external storage.
Lock Function
Explains how to lock/unlock the front panel controls.
Waveform Display
Describes how to view real-time output parameters as waveforms.