Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Aim-TTI Manuals
Power Supply
PLH250
Instruction manual
Aim-TTI PLH250 Instruction Manual
Higher voltage linear dc power supplies
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
page
of
37
Go
/
37
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Introduction
Specification
Safety
Installation
Connections
Manual Operation
Remote Analogue Control (Programmable Models Only)
Remote Interface Operation
Remote Commands
Maintenance
Advertisement
Quick Links
Download this manual
PLH & PLH-P Series
Higher Voltage Linear DC Power Supplies
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the PLH250 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Aim-TTI PLH250
Power Supply Aim-TTI PLH Series Instruction Manual
Higher voltage linear dc power supplies (37 pages)
Power Supply Aim-TTI CPX400S Instruction Manual
Powerflex dc power supply (36 pages)
Power Supply Aim-TTI QL Series II Instruction Manual
(42 pages)
Power Supply Aim-TTI MX180T Instruction Manual
Triple output multi-range dc power supply (44 pages)
Power Supply Aim-TTI QPX1200S Instruction Manual
Powerflex dc (35 pages)
Power Supply Aim-TTI QPX750SP Instruction Manual
Laboratory power supply (48 pages)
Power Supply Aim-TTI MX100T Instruction Manual
Triple output multi-range dc power supply (46 pages)
Power Supply Aim-TTI CPX200D Instruction Manual
Powerflex dual dc power supply (32 pages)
Power Supply Aim-TTI CPX400D Instruction Manual
Powerflex dual dc power supply (34 pages)
Power Supply Aim-TTI EX4210R Instruction Manual
Bench power supply (29 pages)
Power Supply Aim-TTI FX Series Instruction Manual
Laboratory dc power supplies (39 pages)
Power Supply Aim-TTI EL-R Series Instruction Manual
Linear bench power supplies (30 pages)
Power Supply Aim-TTI PowerFlex QPX1200 Series Instruction Manual
(35 pages)
Power Supply Aim-TTI MX100Q Instruction Manual
Triple output multi-range dc power supply (46 pages)
Power Supply Aim-TTI QPX600D Instruction Manual
Powerflex+ dual dc power supplies (38 pages)
Summarization of Contents
Introduction
Specification
OUTPUTS
Details on voltage and current output capabilities and ranges for the power supply series.
Voltage Setting
Describes the method for setting the output voltage using controls.
Current Setting
Explains how to set the output current limit.
Voltage Span Control (V-Span)
Allows user to redefine voltage control end-stop values for precise adjustment.
Settings Lock (S-Lock)
Digital locking feature for voltage and current settings.
Output Mode
Describes constant voltage or constant current operation modes.
Output Switch
Details the electronic, non-isolating output switch functionality.
Output Terminals
Specifies front and rear panel output terminal types and configurations.
Transient Response
Defines the time taken for output to settle after load changes.
Voltage Programming Speed (PLH-P models)
Lists typical times for voltage changes under different load conditions.
Ripple and Noise*
Specifies the typical ripple and noise levels for voltage and current outputs.
Load Regulation
Specifies output voltage and current stability under varying load conditions.
Line Regulation
Describes output stability concerning input line voltage variations.
Temperature Coefficient
Details how temperature affects output voltage and current.
Output Protection
Explains protection against reverse voltage and forward voltage.
OTP Protection
Describes over-temperature protection mechanism.
OVP and OCP Protection (PLH-P models only)
Details over-voltage and over-current protection for programmable models.
METER SPECIFICATIONS
Specifications for the dual 4-digit LED meters.
ANALOGUE REMOTE CONTROL (PLH-P models only)
Describes analogue control inputs for voltage and current.
DIGITAL INTERFACES (PLH-P models only)
Details available digital remote control interfaces like RS232, USB, LAN, GPIB.
GENERAL
Covers general specifications like AC input, power consumption, environment, and safety.
Safety
Installation
Mains Operating Voltage
Instructions for checking and changing the mains operating voltage.
Fuse
Information on the location and rating of the AC fuse.
Mains Lead
Guidance on connecting the instrument to the AC supply.
Mounting
Details suitability for bench and rack mounting.
Ventilation
Instructions regarding airflow and cooling for the instrument.
Connections
Front Panel Connections
Describes how to connect loads and sense terminals on the front panel.
Rear Panel Connections (programmable models only)
Output Terminals
Details of duplicated output terminals on the rear panel.
Analogue Remote Control
Remote On/Off
Manual Operation
Switching On and Power-On Conditions
Explains the power switch operation and initial display sequence.
Output Control
Details on setting and controlling the output voltage and current.
Constant Voltage
Describes operation in constant voltage mode.
Constant Current
Describes operation in constant current mode.
Connection to the Load
Guidance on connecting the load to the instrument's output terminals.
Remote Sensing
Explains the use of remote sense for improved load regulation.
Over-temperature Protection
Details the instrument's response to over-temperature conditions.
View Settings
Describes how to view the set voltage and current limits.
Lock Settings
Explains how to lock and unlock the voltage and current settings.
Using Voltage Span
Remote Analogue Control (programmable models only)
Analogue Voltage Control
Describes remote analogue control of output voltage.
Analogue Current Control
Describes remote analogue control of current limit.
OVP and OCP
Practical Considerations when using CV and CC
Discusses stability and noise when using CV and CC control signals.
Analogue Out Control Voltages
Parallel Operation in Master-Slave Configuration
Isolated or Series Operation in Master-Slave Configuration
Remote Off
Remote Interface Operation
USB remote control
Details USB interface operation and driver installation.
LAN interface
Describes the LXI compliant LAN interface and its features.
Interface Locking
Explains the mechanism for exclusive control of interfaces.
Address Selection
Describes how to set the instrument's address for GPIB and other interfaces.
Remote/Local Operation
RS232 Interface
RS232 Interface Connector
Details the pin configuration of the 9-way D-type RS232 connector.
RS232 Connections
Provides guidance on connecting the RS232 interface to a PC.
USB Interface
LAN Interface
LAN Connection
Web Server; Configuration Password Protection
ICMP Ping Server
VXI-11 Discovery Protocol
mDNS and DNS-SD Support
VISA Resource Name
XML Identification Document URL
TCP Sockets
LAN Error
GPIB Interface
GPIB Subsets
Lists the IEEE 488.1 subsets implemented by the instrument.
GPIB IEEE Std. 488.2 Error Handling – Query Error Register
GPIB Parallel Poll
Status Reporting
Standard Event Status and Standard Event Status Enable Registers
Describes the Standard Event Status and Enable registers per IEEE Std. 488.2.
Execution Error Register
Details the Execution Error Register for reporting errors.
Limit Event Status and Limit Event Status Enable Registers
Covers Limit Event Status registers for over/under limit conditions.
Status Byte Register and Service Request Enable Register
Explains Status Byte and Service Request Enable registers per IEEE Std. 488.2.
Power-on and Remote Operation Default Settings
Remote Commands
RS232/USB Remote Command Format
Specifies the command format for RS232 and USB interfaces.
GPIB Remote Command Formats
Details the command format for the GPIB interface.
Command List
Instrument Specific Commands
Lists commands specific to instrument control and settings.
System and Status Commands
Lists commands for system management and status queries.
Interface Management Commands
LOCAL
Command to return the instrument to local control mode.
IFLOCK
Requests exclusive access control of the instrument interface.
IFLOCK?
Queries the status of the interface lock.
IFUNLOCK
Releases the interface lock if possible.
ADDRESS?
Returns the bus address of the instrument.
IPADDR?
Returns the present IP address of the LAN interface.
NETMASK?
Returns the present netmask of the LAN interface.
NETCONFIG?
Returns the method used for IP address acquisition.
NETCONFIG
Specifies the IP address acquisition method (DHCP, AUTO, STATIC).
IPADDR
Sets the potential static IP address for the LAN interface.
NETMASK
Sets the netmask to accompany the static IP address.
Miscellaneous Commands
Error Messages
Maintenance
Cleaning
Instructions for cleaning the instrument safely.
Web link
Provides a link for manual, driver, and firmware updates.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the PLH250 and is the answer not in the manual?
Questions and answers