Table of Contents

Advertisement

Operating Manual
BD-S / BD-S-UL (E1)
ED-S / ED-S-UL (E1)
FD-S / FD-S-UL (E1)
with R-S microprocessor temperature controller
Model
Model version
BD-S 56
BDS056-230V
BD-S-UL 56
BDS056UL-120V
BD-S 115
BDS115-230V
BD-S-UL 115
BDS115UL-120V
ED-S 56
EDS056-230V
ED-S-UL 56
EDS056UL-120V
ED-S 115
EDS115-230V
ED-S-UL 115
EDS115UL-120V
FD-S 56
FDS056-230V
FD-S-UL 56
FDS056UL-120V
FD-S 115
FDS115-230V
FD-S-UL 115
FDS115UL-120V
BINDER GmbH
 Address: Post office box 102, 78502 Tuttlingen, Germany  Phone: +49 7462 2005 0
 Fax: +49 7462 2005 100  Internet: http://www.binder-world.com
 E-mail: info@binder-world.com  Service Hotline: +49 7462 2005 555
 Service Fax: +49 7462 2005 93 555  Service E-Mail: service@binder-world.com
 Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3
 Service Hotline Asia Pacific: +852 390 705 04 or +852 390 705 03
 Service Hotline Russia and CIS: +7 495 988 15 16
Issue 05/2019
Incubators with natural convection
Drying and heating ovens with natural
convection
Drying and heating ovens with forced
convection
Art. No.
9090-0016, 9190-0016
9090-0017, 9190-0017
9090-0022, 9190-0022
9090-0023, 9190-0023
9090-0014, 9190-0014
9090-0015, 9190-0015
9090-0020, 9190-0020
9090-0021, 9190-0021
9090-0018, 9190-0018
9090-0019, 9190-0019
9090-0024, 9190-0024
9090-0025, 9190-0025
Art. No. 7001-0359

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BD-S 115 and is the answer not in the manual?

Questions and answers

Summarization of Contents

SAFETY
Legal considerations
Discusses legal aspects and responsibilities related to manual usage.
Structure of the safety instructions
Explains the format and elements used in safety instructions within the manual.
Localization / position of safety labels on the chamber
Details the placement of safety labels on the chamber for user awareness.
Type plate
Provides information about the chamber's identification and specifications on its type plate.
General safety instructions on installing and operating the chambers
Outlines essential safety guidelines for chamber installation and operation.
Intended use
Defines the appropriate applications and limitations for the chamber's operation.
CHAMBER DESCRIPTION
Chamber overview
Provides a general overview of the chamber's components and layout.
Triangular instrument panel
Describes the function and components of the triangular instrument control panel.
COMPLETENESS OF DELIVERY, TRANSPORTATION, STORAGE, AND INSTALLATION
Unpacking, and checking equipment and completeness of delivery
Instructions for unpacking, inspecting the chamber, and checking for delivery damage.
Guidelines for safe lifting and transportation
Provides guidance on safely lifting, moving, and transporting the chamber.
Storage
Details conditions and procedures for storing the chamber when not in use.
Location of installation and ambient conditions
Specifies requirements for the installation site and ambient environmental conditions.
INSTALLATION
Installing the racks
Step-by-step guide for installing the internal racks within the chamber.
Connection to an exhaust/ventilation system (optional)
Instructions for connecting the chamber to an optional exhaust or ventilation system.
Electrical connection
Details the necessary steps for the electrical connection of the chamber.
R-S CONTROLLER OVERVIEW
Menu structure overview
Explains the menu structure and navigation of the R-S controller.
START UP
Adjusting air change.
Describes how to adjust the air change rate for optimal chamber performance.
SELECTING THE TEMPERATURE UNIT
Setting the temperature unit
Procedure for changing the temperature display unit between Celsius and Fahrenheit.
OVERTEMPERATURE PROTECTION
Overtemperature protective device (class 1)
Details the function and operation of the class 1 overtemperature protective device.
Safety controller
Explains the safety controller's role in preventing temperature exceedances.
Setting the safety controller
Steps for configuring the safety controller's limit temperature set-point.
Alarm message and proceeding in case of an alarm
Describes alarm messages and actions to take when a safety controller alarm occurs.
TIMER FUNCTION "DELAYED OFF"
Setting the timer run-time.
Guide on how to set the delay time for the automatic shut-off timer function.
RAMP FUNCTION
Setting the ramp
Instructions for setting up a temperature ramp for controlled heating.
Setting the gradient
Details how to define the temperature rise rate (gradient) for a ramp function.
Display of the ramp course
Explains how the ramp progression is displayed on the controller.
Turning off the ramp function
Procedure for deactivating the programmed ramp function.
OPTIONS
Data logger kits (option)
Information on optional data logger kits for temperature monitoring.
MAINTENANCE, CLEANING, AND SERVICE
Maintenance intervals, service
Specifies recommended maintenance schedules and service requirements.
Cleaning and decontamination
Procedures for cleaning and decontaminating the chamber after use.
Cleaning
Detailed steps for cleaning the chamber's interior and exterior surfaces.
Decontamination
Guidelines for decontaminating the chamber from hazardous substances.
Sending the chamber back to BINDER GmbH
Instructions for returning the chamber for repair or other service.
DISPOSAL
Disposal of the transport packing
Information on the proper disposal methods for packaging materials.
Decommissioning
Steps to follow for decommissioning the chamber before final disposal.
Disposal of the chamber in the Federal Republic of Germany
Regulations and procedures for disposing of the chamber in Germany.
Disposal of the chamber in non-member states of the EU
Procedures for disposing of the chamber in countries outside the European Union.
TECHNICAL DESCRIPTION
Factory calibration and adjustment
Details the factory calibration process and adherence to quality standards.
Definition of usable volume
Explains how the usable internal volume of the chamber is calculated.
Over current protection
Describes the over-current protection mechanisms, including fuses.
Technical data
Presents detailed technical specifications and performance data for the chambers.
Equipment and options (extract)
Lists standard equipment and available optional accessories for the chambers.
Accessories and spare parts (extract)
Provides a list of common accessories and spare parts for the chambers.
Dimensioned drawings
Presents detailed dimensional drawings for various chamber models.
BD-S / BD-S-UL 56
Detailed dimensional drawings for the BD-S / BD-S-UL 56 model.
BD-S / BD-S-UL 115
Detailed dimensional drawings for the BD-S / BD-S-UL 115 model.
ED-S / ED-S-UL 56
Detailed dimensional drawings for the ED-S / ED-S-UL 56 model.
ED-S / ED-S-UL 115
Detailed dimensional drawings for the ED-S / ED-S-UL 115 model.
FD-S / FD-S-UL 56
Detailed dimensional drawings for the FD-S / FD-S-UL 56 model.
FD-S / FD-S-UL 115
Detailed dimensional drawings for the FD-S / FD-S-UL 115 model.
Certificates and declarations of conformity
EU Declaration of Conformity for BD-S
Official EU declaration confirming the BD-S model's compliance with directives.
EU Declaration of Conformity for ED-S
Official EU declaration confirming the ED-S model's compliance with directives.
EU Declaration of Conformity for FD-S
Official EU declaration confirming the FD-S model's compliance with directives.
Certificate for the GS mark of conformity of the “VDE Prüf- und Zertifizierungsinstitut”
Certificate confirming GS mark conformity from VDE Testing and Certification Institute.
Certificate of UL Compliance from Underwriters Laboratories Inc.
Certificate confirming UL compliance for specified chamber models.
Contamination clearance certificate
For chambers located outside the USA and Canada
Form and instructions for contamination clearance for returns outside North America.
For chambers located in the USA and Canada
Form and instructions for contamination clearance for returns within North America.

Table of Contents