User´s and installation manual DRY 300/400/500/800/1200 DUCT 7.6.23 Thank you for purchasing Microwell swimming pool dehumidifier. You have exceptional piece of device and you chose the best and the most energy efficient dehumidifier for your pool. Before you use this device, it is necessary to carefully read the entire User’s manual.
Model Microwell DRY 300 DUCT is designed for halls with swimming pool surface of up to 30m Model Microwell DRY 400 DUCT is designed for halls with swimming pool surface of up to 40m Model Microwell DRY 500 DUCT is designed for halls with swimming pool surface of up to 50m .
4/73 | User´s and installation manual DRY 300/400/500/800/1200 DUCT 7.6.23 this User’s manual may lead to an injury or property damage and will lead to loss of warranty. To prevent injury or property damage the following instructions must be followed: 2.1 ELECTRICAL SAFETY •...
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 5/73 2.3 HANDLING PRECAUTIONS Leave the unit in a vertical upright position for at least Keep in vertical 2 hours before mounting. It is necessary to stabilize the position for 2 hours refrigerant charge and especially to return the oil to the compressor tray.
Page 6
6/73 | User´s and installation manual DRY 300/400/500/800/1200 DUCT 7.6.23 • Please notify your reseller or distributor if the delivered unit had been damaged. The unit may appear to work fine at first, but minor damage may cause the unit to stop working properly in a short time. In this case the unit must be inspected and its further use must be approved by the seller.
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 7/73 3. PRODUCT DESCRIPTION The unit was delivered in carton box on a wooden palette. Please unpack the unit and check the content. It should include the following: Package: Name/ code Image Name/ code Image...
Page 9
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 9/73 6 – Air filter 7 – Defrost thermostat Installed inside the device Please note that pictures may differ. List of necessary tools (is not part of packaging): Názov/ kód Obrázok Názov/ kód Obrázok 1 - Drill...
10/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 1.1. Description of basic parts Legend: DRY300/400 DUCT 1 – Air exhaust / AIR OUT/ = supply for pool hall 2 – Air suction /AIR IN/ = exhaust from pool hall 3 –...
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 11/73 1.2. Air connection options 1.2.1. DRY300/400 DUCT Flange Hatch Connection marking Connection type connection for Thread dimensions air ducting 300x100mm 320x120mm Air inlet from bottom 300x100mm 320x120mm Air outlet from the top 300x100mm 325x125mm Air inlet from the front...
Page 12
12/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 1.2.2. DRY500 DUCT Flange Hatch Connection marking Connection type connection for Thread dimensions air ducting 500x100mm 520x120mm Air inlet from bottom 500x100mm 520x120mm Air outlet from the top Air inlet from the front 500x100mm 510x120mm Flange connection for air...
Page 13
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 13/73 DRY500 DUCT AIR OUTLET TO THE TOP S2 AIR OUTLET TO THE FRONT F2 AIR INLET FROM THE BOTTOM AIR INLET FROM THE FRONT...
Page 14
14/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 1.2.3. DRY800/1200 DUCT Flange Opening Connection marking Connection type connection for Thread dimensions air ductiong 700x100mm 720x120mm Air inlet from the back 700x100mm 720x120mm Air outlet from the back 700x100mm 725x125mm Air inlet from the front...
Page 15
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 15/73 DRY800 DUCT, DRY1200 DUCT AIR OUTLET TO THE BACK A2 AIR OUTLET TO THE TOP C2 AIR OUTLET TO THE FRONT B2 AIR INLET FROM THE BACK AIR INLET FROM THE FRONT AIR INLET FROM THE...
If your dehumidifier is equipped with a hot water element and/or a solenoid valve, you must use built- in digital controller OR MICROWELL DRY EASY300 wireless humidistat and thermostat OR EBERLE HYG7001 thermostat and hygrostat to activate the air heating function with a dehumidifier, or you must have an external thermostat connected.
18/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 The dehumidifier can be equipped with a solenoid valve on request. When used in combination with a hot water coil, it has a similar function to the fan coil, i. the fan works independently with the compressor (humidistat) and independently with the LPHW hot water coil (thermostat).
Page 19
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 19/73 The manufacturer recommends setting the required humidity value on the DRY EASY 300 in the range of 55 to 65% RH. If the backup humidistat had been set to a lower value than the DRY EASY 300 remote humidistat, the backup humidistat will take over the room humidity control and in this case the dehumidifier will not respond to signals from the DRY EASY 300 remote humidistat.
20/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 Location of receiver and antenna A: The receiver is located inside the electrobox and the antenna is located on the outside of it. B: For TTW version / through the wall / we recommend pulling the antenna into the pipe in the wall.
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 21/73 If your dehumidifier is equipped with a hot water insert and/or a solenoid valve also, you must use a humidistat with an EBERLE HYG7001 thermostat to activate the dehumidifier’s air heating function, or you must have an external thermostat connected.
Page 22
22/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 If the failure reporting continues, please ask us to change the component. Sensor failure. The electrical connection of the sensor is broken off. Please control the cable. Sensor failure. The sensor is short-circuited. Please control the cable. User setting HUMIDITY / TEMPERATURE changing ( /* Manufacturer settings) Press SET key for 10secs...
Page 23
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 23/73 Press SET key for 10secs Displayed immediately Displayed after 10 secs Press SET button shortly TEMPERATURE output type select „ “ HUMIDITY output type select „ “...
Page 24
24/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 Program setting ( /* Manufacturer settings) TEMPERATURE output type select Cooling Heating /* TEMP. output delay time setting Change TEMP. output Double(+/-) hysteresis hysteresis type select Single.(+) hysteresis setting Setting /* TEMP.
TEMP. display mode 4.2 Control of the fan A fan is very important part of a dehumidifier. Microwell has programmed the fan functionality in order to ensure absolute humidity control in your pool with strong focus on energy efficiency. For this reason all ducted dehumidifier models’s (DRY300DUCT, DRY400DUCT DRY500DUCT, DRY800DUCT and...
5.1 Location of the equipment DRY 300 DUCT, DRY 400 DUCT, DRY 500 DUCT, DRY 800 DUCT and DRY 1200 DUCT are designed to be installed in technical rooms. All models are IP44 protected. For...
Page 28
28/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 DRY 300/400/500 DUCT - Please use installation layout. It is 1:1 scale drawing of the dehumidifier with markings for wall console screws, side fixation screws, water drainage, electrical power supply and LPHW connection from the back. Brief installation instructions: DRY 300/400/500 DUCT 1.
Page 29
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 29/73 pay attention to the location of the electricity supply and the condensate drain! Available for DRY300- 400-500DUCT. Brief installation instructions (DRY300/400/500 DUCT) etermine a location for mounting the dehumidifier. Choose a suitable position respecting all the rules described above.
Page 30
30/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 +/- 0.3% 6. Secure console with the supplied or other suitable screws. The console must be in a horizontal position with a maximum deviation of +/- 0.3%! 7. Secure dehumidifier onto the console.
Page 31
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 31/73 8. You will now need to remove the cover of the dehumidifier, to connect the power supply and condensate drain. The cover can be removed after loosening 2 screws (DRY 300/400) or 3 screws (DRY 500) on the bottom part of the device 9.
Page 32
32/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 10. In the lower left part, there is a condensate drain hose, which must be inserted into the sewer pipe (rear). Never drain condensate into the pool, it may contain dangerous bacteria. The lower part of the dehumidifier can be slightly pulled together and thus have access to the condensate.
Page 33
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 33/73 El. supply Drainage Preparation of electric power supply, condensate drain and console mounting Brief installation instructions (DRY800/1200 DUCT) WALL CONSOLES 3. Remove the 4 M8 screws that secure the dehumidifier to the palet. WARNING! Do not unscrew the M6 screws.
Page 34
34/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 Floor installation 2. Floor installation is complete. Finally, After removing 4 M8 screws, insert 4 attach the dehumidifier to the wall as rubber feet instead. shown below.
Page 35
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 35/73 Not included in packaging. Wall installation of DRY80/1200 DUCT – on demand If the dehumidifier is being installed on a wall, it is necessary to order a set of brackets for wall mounting.
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 37/73 5.3 Compressor transport protection Your compressor is protected for the transport with plastic zipper strap. Due to compressor size and weight this is necessary in order to have a fully functional unit delivered to you safely. This protection must be removed before starting the unit.
Page 38
38/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 must be drained through a siphon to the sewer or to the outside environment. Please do not place the drain hose upwards (against gravity), as this may cause the appliance to be unable to drain water condensate.
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 39/73 Condensate drain Condensate Overflow drain 5.5 Main power supply connection Main electrical connection for fixed cable in wall As standard, the dehumidifiers are connected to a fixed cable in the wall. Connecting the device to an electrical network must comply with the relevant security standards.
Page 40
40/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 Standard terminal block - L, N, ground Main power supply Dehumidifier type El. cable Circuit breaker DRY 300 CYSY 3x 1,5 mm 10 A typ C DRY 400 CYSY 3x 1,5 mm 10 A typ C DRY 500 CYSY 3x 2,5 mm...
Page 41
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 41/73 MAIN ELECTRICAL CONNECTION OF THE DEHUMIDIFIER 230V/50Hz/1f 3x 2.5mm2 CYSY breaker 10A type C EBERLE HYG6001 connection for DRY 500 circuit breaker 30mA MAIN ELECTRICAL Black box from the SIDE of the CONNECTION OF THE electrobox DEHUMIDIFIER...
Page 42
42/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 Black box from the SIDE of the electrobox Black box from the FRONT of the electrobox EBERLE HYG7001 connection for DRY 500 POTENCIAL-FREE CONTACT POTENTIAL CONTACT- NO / Normal Open / - If the air is heated, then C / closed / MAIN ELECTRICAL CONNECTION OF THE...
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 43/73 Black box from the FRONT of the electrobox Electric heating element connection for DRY 300/400/500 EL. HEATING POWER SUPPLY 230V/50Hz/1f Cable: 3x2.5mm2 CYSY Power consumpation: 2kW (DRY300/400), 3kW (DRY500) Circuit breaker: 16A MAIN ELECTRICAL CONNECTION OF THE DEHUMIDIFIER 230V/50Hz/1f...
Page 44
44/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 It is suggested to drain the water from siphon into an external drain, pool compensation tank etc. If the water will be drained into a sewer system, it is advised to regularly fill the siphon with water to avoid unpleasant odor.
46/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 LPHW heating coil for additional heating – on demand The LPHW heater element is supplied on demand only. Connection of the LPHW onto the LPHW plumbing is carried out similarly to the installation of radiators. On the feeder pipe, it is connected by a control valve and on the return pipe by a closing screw joint.
External installation Your Microwell dehumidifier can be installed outdoors if you ordered it with an outdoor kit. In such case the dehumidifier is equipped with additional compressor heater, condensate tray defrost and the whole unit is specially insulated with thicker layer of thermal insulation to avoid condensation on its structure.
Page 48
48/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 Please proceed as per below when installing the through the wall: DRY 300-400-500 DUCT DRY 800-1200 DUCT (On demand) Always insulate the exceeding parts of the air ducting in order to avoid condensation on the ducts‘ structure.
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 49/73 Remark for outdoor installation: Although your dehumidifier unit is equipped with special thermal insulation, antifreeze protectors and its chassis is made from galvanized metal powder coated by enamel at 180°C, it is advised to avoid a direct sunlight, rain or snow to fall onto the unit.
50/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 Air filter replacement 1.Remove the screws. 2. Remove the filter cover. 3. Pull out the filter. 4. Replace the filter. Put a new air filter and follow the same procedure, but in reverse order. Cover removal Lower the side cover caps, unscrew and remove the side cover screws.
Page 51
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 51/73 DRY 800-1200 DUCT Lift the cover as shown in the illustration. Disconnect the connectors on the display on the left side under the cover. accessories Place the cover sideways on a foam pad or cardboard so that you do not scratch the cover on the floor.
6-Top LPHW, El. coil, Condenser Your Microwell DUCT dehumidifier allows you to access, inspect, maintain or service inner parts of the dehumidifier without necessity to de-install the air ducting and/or unit main chassis cover. This allows the maintenance or service to be easier and faster. Each compartment is...
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 53/73 6. TECHNICAL DATA 6.1 Technical data table * DRY 300 DRY 400 DRY 500 DRY 800 DRY 1200 DATA UNIT DUCT DUCT DUCT DUCT DUCT For swimming pools with max. water surface Exctraction rate at 30°C and 60 % l/24hrs...
Page 54
6.2 Ventilator & Extraction rate diagrams DRY 300/400 DUCT Each Microwell DUCT dehumidifier is supplied with manual fan speed control. This allows manual settings of its speed in range of 65~100%. This is used to optimize performance/noise level ratio by each particular installation. Use at maximum for beginning or testing. Once your installation is fully completed (with all air ducting elements), please adjust the knob left- rightwards to fit into your performance and noise level preferences.
Page 55
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 55/73 DRY 500/800/1200 DUCT DRY 300 DUCT (l/24h) Air temperature (°C)
Page 56
56/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 DRY 400 DUCT (l/24h) Air temperature (°C) DRY 500 DUCT (l/24h) Air temperature ( °C DRY 800 DUCT...
Page 57
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 57/73 DRY 1200 DUCT LEGEND: DRY AIR OUTLET DIGITAL HUMIDITY REGULATOR LPHW CONNECTOR – ON DEMAND MAIN SWITCH HUMID AIR INLET AUXILIARY MECHANICAL HUMIDISTAT CONDENSATE DRAIN FROM THE BOTTOM ELECTRICITY CONNECTION 10 - CONDENSATE DRAIN FROM BEHIND 6.3 Unit´s dimensions DRY 800/1200 DUCT...
Page 58
58/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 DRY 300/400 DUCT DRY 500 DUCT View from above From left Front view From right View from below...
Page 65
7.6.23 User´s and installation manual DRY 300/400/500/800/1200 DUCT | 65/73 7. SUMMER SHUT-DOWN Some swimming pool users use to shut the dehumidifier for summer down. This is mainly due to favourable weather conditions with dry and warm weather. In such case, good air ventilation / natural air exchange does the job of humidity control for few weeks/months of the year.
Page 66
66/73 | User´s and installation manual DRY 3 00/400/500/800/1200 DUCT 7.6.23 Acidity / pH level: 7,4 +/- 0,4 Total alkalinity, as CaCO3 80-120 Total hardness, as CaCo3 100-300 Total melted dry mass max. 3000 Maximum salt content wt/wt 0.3% (3,000 ppm, 3 kg of salt per 1 m of water) (standard dehumidifier) Maximum salt content...
Page 73
User´s and installation manual DRY 300/400/500/800/1200 DUCT | 73/73 Distributor: Manufacturer: MICROWELL, spol. s r.o. SNP 2018/42, 927 01 Šaľa, Slovakia tel.: +421/31/770 7082 e-mail: microwell@microwell.sk w w w . m i c r o w e l l . e u...