  • Page 1 WALL-MOUNTED SWIMMING POOL DEHUMIDIFIER USER S & INSTALLATION MANUAL ´ MODEL: DRY 300 & 500 SILVER/METAL...
  • Page 2: Safety Measures

    The units are designed especially for use in indoor swimming pools, spas and saunas. They can also be very useful in laundries, drying rooms and elsewhere. Microwell DRY 300 SILVER/METAL is designed for rooms with a swimming pool, which surface is up to 30 m . ²...
  • Page 3 INSTRUCTIONS FOR USE 3.1. Humidity regulation with an inbuilt digital humidistat located in the cover of the equipment The inbuilt humidistat is located in the cover of the device. It reads the humidiy of the incoming air, and depending on the set value, switches on the compressor.
  • Page 4 Program setting Current humidity or current temperature display. Keep the “set” button pressed for longer than 5 secs. Setting of the additional output Programming point “1” which is not connected. Setting of the main output´values Don´t perform any settings here and return to the point Function s etting...
  • Page 5: Maintenance Instructions

    3.2. Humidity regulation with a back-up mechanical humidistat located in the electronic box In the electronic box there is a back-up mechanical humidistat, which is set on the value of 70 % RH. This humidistat has a back-up function in case of digital humidistat failure. User should not perform any regulation of this humidistat. 3.3.
  • Page 6 There is an installation bracket included in the equipment accessories, which must be fixed on the wall. The axis of the fixation slots is 210 mm lower than the top edge of the device. The distance between the fixation slots is 420 mm (DRY 300 SILVER/METAL) and 360 mm (DRY 500 SILVER/METAL).
  • Page 7 Connecting the device onto the mains and protection securing must satisfy the requirements of relevant norms. Connection requirements are the following: 220-240 V/50Hz, protection 10A (DRY 300 SILVER/METAL) and 16A (DRY 500 SILVER/METAL) with a mains-fuse that has a current-carrying differential disconnecting capacity, not exceeding 30mA. There is a terminal for connection to the mains, located on the left hand side of the device.
  • Page 8 DEVICE LOCATION Device location must be in accordance with HD 384.7.702 S1 and IEC 60364-7-702 standard. It is recommended to locate the device outside zones 0,1 and 2. In case the device is located into zones 2 or 1, HD and IEC standards´requirements must be satisfied. ZONE 1, IPX4 Swimming pools which are not cleaned by splashing water...
  • Page 9 6.7. LPHW heater element - to order The LPHW heater elements are supplied only to order. Connection of the hot water heater element onto the LPHW plumbing is carried out similarly to the installation of radiators. On the feeder pipe, it is connected by a control valve and on the return pipe by a closing screw joint.
  • Page 10 Technical data DRY 500 SILVER/METAL DRY 300 SILVER/METAL TECHNICAL DATA UNITS For swimming pools with max. surface DEHUMIDIFICATION PERFORMANCE: l/24 h at 30 °C and 60 % RH l/24 h at 30 °C and 70 % RH l/24 h at 30 °C and 80 % RH °C...
  • Page 11: Front View

    DRY 300 SILVER/METAL swimming pool dehumidifier parameters FRONT VIEW SIDE VIEW SLIPPING OUT FROM A CONSOLE PREVENTING SLIPPING OUT FROM A CONSOLE PREVENTING POSITION SECURING (FROM BEHIND) POSITION SECURING (FROM BEHIND) CONSOLE CONDENSATE DRAIN (FROM THE BEHIND) PIPE WITH AN INTERNAL DIAMETER OF MINIMUM 16 mm POWER SUPPLY (FROM THE BEHIND) CYSY WIRE 3C x 1.5 mm...
  • Page 12 WIRING DIAGRAM OF MODEL MICROWELL DRY 300 SILVER/METAL DRY 300 Standard DRY 300 DRY 300 LPHW / EASY 200 / Solenoid HYG 6001 METAL DRY 300.1 DRY 300.1 DRY 300.2 SILVER DRY 300.1 DRY 300.1 DRY 300.2 DRY 300.1 Note: Producer reserves right to make changes on wiring.
  • Page 13 DRY 300.2 Note: Producer reserves right to make changes on wiring. Note: Producer reserves right to make changes on wiring. WALL-MOUNTED SWIMMING POOL DEHUMIDIFIER - OWNER´S & INSTALLATION MANUAL...
  • Page 14 WIRING DIAGRAM OF MODEL MICROWELL DRY 500 SILVER/METAL DRY 500 Standard DRY 500 DRY 500 LPHW / EASY 200 / Solenoid HYG 6001 METAL DRY 500.1 DRY 500.1 DRY 500.2 SILVER DRY 500.1 DRY 500.1 DRY 500.2 DRY 500.1 Note: Producer reserves right to make changes on wiring.
  • Page 15 DRY 500.2 Note: Producer reserves right to make changes on wiring. Note: Producer reserves right to make changes on wiring. WALL-MOUNTED SWIMMING POOL DEHUMIDIFIER - OWNER´S & INSTALLATION MANUAL...
  • Page 16: Expanded View

    EXPANDED VIEW Number Position Component of pieces Metal / Stainless stell cover Digital humidistat FOX-2SH Humidity sensor DS-SH104 Back metal sheet Ventilator metal sheet Metal sheet in front of the exchanger Metal sheet above the exchanger Metal sheet under the compressor Electro-box metal sheet Compressor cover Evaporator tray...
  • Page 17: Warranty Conditions

    When applying applicable warranty, the registration card that ensures applicable warranties must be returned. In case you cannot find the registration card of your dehumidifier, please contact the Service department of Microwell, Ltd. - indicated your name, address and serial number of your dehumidifier.
  • Page 19 MICROWELL, Ltd. Distributed by: SNP 2018/42 927 01 Šaľa, Slovakia Phone: +421 31 7020 540-1 Fax: +421 31 7020 542 E-mail: microwell@microwell.sk www.microwell.eu Version: 2013/07/16...

Table of Contents