DayTronic 4077 Instruction Manual

DayTronic 4077 Instruction Manual

Single-channel dc strain gage instrument
Hide thumbs Also See for 4077:

Advertisement

MODEL
4077
SINGLE-CHANNEL
DC STRAIN GAGE
INSTRUMENT
INSTRUCTION MANUAL
4000
Instrument Series
SB.7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4077 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Model 4077 Description and Specifications
Physical Layout
Details the front and rear panel components and overall physical arrangement of the instrument.
Panel Mounting
Instructions for securely installing the Model 4077 unit into a precut panel.
Standard Channel Configuration
Outlines the default setup and function of each channel in the standard configuration.
Standard Logic Configuration
Explains the default logic input/output configuration and its functions.
Using the Front-Panel Setup Buttons
Guides users through basic instrument setup and parameter adjustment using front-panel buttons.
Entering "Setup" Mode
Procedure to enter the instrument's setup mode using the SET UP button.
Selecting a Channel for Setup and/or Review
Method to choose a specific channel for configuration review or modification.
Stepping Through a Channel's Parameter List
Process for navigating through a channel's configuration parameters.
Moving the "Active" Digit
How to shift focus between digits for parameter editing.
Modifying the "Active" Digit
Steps to change the value of the currently selected digit.
Modifying the Polarity of the Displayed Value
How to change the sign (positive/negative) of a displayed parameter value.
Adding a Decimal Point or Modifying the Decimal-Point Location
Procedure for adding or repositioning decimal points in parameter entries.
Exiting "Setup" Mode
How to save changes and return to normal operation mode.
Low Battery Warning
Informs about the internal battery status and the warning indicator displayed on the unit.
Powerup
AC Operation
Instructions for operating the instrument using standard AC power sources.
DC Operation
Guidelines for operating the instrument from a DC power source, such as a vehicle battery.
"Computed" and "Simulated" Calibration
"Computed" Calibration: MVV
Details the MVV command for faster, more convenient instrument calibration.
"Simulated (Shunt)" Calibration: SHP and SHN
Explains the SHP/SHN commands for simulating input via a shunt resistor.
Cabling & Calibration of a 4077 That Uses an Optional Model 10CJB-2 Bridge Completion Card
10CJB-2 Cabling
Instructions for connecting various bridge configurations using the 10CJB-2 card.
10CJB-2 Calibration
Details calibration methods specifically for channels using the 10CJB-2 card.
Analog Peak Capture
Setup of Peak-Capture Channels: EMM and BEE
Guides the setup of EMM and BEE for analog peak capture channels.
"+PEAK" Capture: PKP
Explains how to control the "+PEAK" channel using PKP commands or logic inputs.
"-PEAK" Capture: PKN
Explains how to control the "-PEAK" channel using PKN commands or logic inputs.
Holding Analog Peaks without Decay: CLC
Describes using the CLC command to hold captured peak values without decay.