Basic Setup
Covers basic setup operations like language, clock, and display configuration.
Configure Measurement
Details configuration of measurement parameters including dependencies and generator/mains data.
Configure Transformer
Explains configuration of potential and current transformers for generator and mains.
Discrete Inputs
Details discrete inputs, including warnings and configuration for normally open/closed states.
Discrete Outputs
Explains programmable and fixed discrete outputs and their application modes.
Generator
Details monitoring functions for generator parameters like voltage, frequency, and current.
Mains
Covers monitoring functions for mains parameters like voltage, frequency, and power.
Engine
Details monitoring functions for engine parameters like overspeed, underspeed, and speed detection.
Breaker
Covers configuration and monitoring for Generator Circuit Breaker (GCB) and Mains Circuit Breaker (MCB).
Configure GCB
Details circuit breaker monitoring, including reclose and open alarms for GCB.
Configure MCB
Covers circuit breaker monitoring for MCB, including reclose and open alarms.
Parameters
Details parameters for application modes, including breaker transition modes.
Analog Inputs
Details configuration of analog inputs, including characteristic curves and scaling points.
Discrete Inputs
Details discrete input configuration, including alarm classes and pre-assigned functions.
Analog Outputs
Details analog outputs 1 and 2 configuration, including PWM signal and hardware type.
Engine
Covers engine type configuration, including start/stop logic and diagrams.
Engine Type
Details engine type configuration (Diesel, Gas, External) and start/stop sequences.
Magnetic Pickup Unit
Explains MPU input configuration, including flywheel teeth and speed measuring range.
Idle Mode
Covers idle mode configuration, including its effect on monitoring and exceptions.
Automatic Run
Explains automatic engine start conditions and breaker logic.
Critical Mode
Details critical mode operation, including alarm reclassification and conditions.
PID {x} Control
Explains PID controller configuration, including parameters like Proportional, Integral, and Derivative gain.
Frequency Control
Details frequency control functions, including kick impulse and droop characteristics.
Load Control
Covers load control configuration, including setpoints and ramp settings.
Power Factor Control
Details power factor control tasks, including PID and three-step controller options.
Configure Breakers
Covers configuration of breaker logic modes like Parallel, Open Transit, Closed Transit, and External.
Dead Bus Closing GCB
Explains dead busbar closure for GCB, including automatic and manual operations.
Dead Bus Closing MCB
Explains dead busbar closure for MCB, including automatic and manual operations.
Open GCB
Details conditions for opening the GCB, including stop modes and alarm conditions.
Open MCB
Explains conditions for opening the MCB, including emergency power and softkey operations.
Parameters
Details parameters for application modes, including breaker transition modes.